3 phase Nema 42 Stepper motor, 5A, 1.2 degree, 6 wires

$292.62
The Nema 42 stepper motor is a professional and high precision stepper motor with 1.2 deg. step angle, 3 phase 6 wires, high holding torque of 22Nm, direct sale by manufacturer.
SKU: ATO-STEP-31504205
*
Free Shipping
Delivery date: 6-12 days

The Nema 42 stepper motor with 1.2 degree step angle, 3 phase 6 wires, high holding torque of 22Nm, manufacturer direct sale.

Specifications

BasicsModelATO3150-5006A
Matched the Driver ModelATODSP86 (Click it to see more info)
Step Angle1.2°
Length150mm
Weight8.5kg
Current5A
Resistance1.2Ω
Holding Torque22Nm
Motor Leads6
Rotor Inertia11000g-cm2
Technical parametersStep Angle Accuracy±5% (full step, no load)
Resistance Accuracy±10%
Inductance Accuracy±20%
Temperature Rise80℃Max. (rated current, 2 phase on)
Ambient Temperature-10℃~+50℃
Insulation Resistance100MΩ Min. 500VDC
Dielectric Strength1Min. 500VAC·5mA
Shaft Radial Play0.06Max. 450g
Shaft Axial Play0.08Max. 450g

 Dimension
Nema 42 3 phase demension
Wiring Diagram
Nema 42 wiring diagramnema 42 3 phase connection
Tips: Solutions to the power interference of stepper motor

At many occasions, due to the high current and voltage of the stepper motor, e.g.: For some stepper motor, the maximum current: 8A and voltage: 325V, and magnetic shielding of its shell is not implemented with aluminum alloy shell, the interference in high-sensitive receiver system is caused, so that it cannot work normally and power interference is also caused. Especially the frequency is high, normal communication cannot be realized on SCM and upper computer of the control system. If serious, SCM will be halted, then the difficulty will be brought to the normal use. Therefore, the interference should be solved.
Solutions to power interference of stepper motor are as below:

  1. Install power filter to reduce the contamination of AC power.
  2. Reduce the the external interference in power line with the shielded line or the interference of power line in external world.
  3. Based on the principle of "single-point-earthing", earth the grounding of power filter and stepper driver PE (the baseboard of driver and chassis should be insulated.), control pulse and direction pulse DIR-outgoing lines of short circuit, motor earthing line, cable protecting cover between driver and motor and shielded wire of driver to the earthing rod on wall of chassis, and good contact should be realized.
  4. Lengthen the distance between control line, power line (L and N) and motor drive line (U, V and W) to avoid crossing, e.g. when dealing with the driver installation site of two drivers of the same chassis in the double-shaft system, put the nameplate of one driver forward and that of the other backward, and shorten the leads as far as possible when making structural arrangement.

Stepper Motors vs. Servo Motors: Quick Comparison

In this video, stepper motors and servo motors are compared in different aspects.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Stepper Motor Wiring

In this video, the process of stepper motor wiring is introduced to you. The stepper motor driver can accept NPN or PNP line pulse signals. If the driving pulse is 12V, a 1kΩ resistor is required in series. If it is 24V, a 2kΩ resistor is required.

Product reviews
Connection mode of three phase stepper motor
5
Mommy
Avatar
4/21/2021 9:51 PM
How the three phase internal winding of the stepper motor are connected together?
Was this review helpful? Yes No (0/0)
ATO Responded
The internal winding of three phase stepper motor is star connection.
Nema 42 stepper motor is as described
5
Drosy
Avatar
8/16/2022 1:52 AM
Nema 42 stepper motor is as described. It functions well overall, pin connections were good, no visible scratches or dents. I will recommend this nema 42 stepper motor to my friends.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The Nema 42 stepper motor with 1.2 degree step angle, 3 phase 6 wires, high holding torque of 22Nm, manufacturer direct sale.

Specifications

BasicsModelATO3150-5006A
Matched the Driver ModelATODSP86 (Click it to see more info)
Step Angle1.2°
Length150mm
Weight8.5kg
Current5A
Resistance1.2Ω
Holding Torque22Nm
Motor Leads6
Rotor Inertia11000g-cm2
Technical parametersStep Angle Accuracy±5% (full step, no load)
Resistance Accuracy±10%
Inductance Accuracy±20%
Temperature Rise80℃Max. (rated current, 2 phase on)
Ambient Temperature-10℃~+50℃
Insulation Resistance100MΩ Min. 500VDC
Dielectric Strength1Min. 500VAC·5mA
Shaft Radial Play0.06Max. 450g
Shaft Axial Play0.08Max. 450g

 Dimension
Nema 42 3 phase demension
Wiring Diagram
Nema 42 wiring diagramnema 42 3 phase connection
Tips: Solutions to the power interference of stepper motor

At many occasions, due to the high current and voltage of the stepper motor, e.g.: For some stepper motor, the maximum current: 8A and voltage: 325V, and magnetic shielding of its shell is not implemented with aluminum alloy shell, the interference in high-sensitive receiver system is caused, so that it cannot work normally and power interference is also caused. Especially the frequency is high, normal communication cannot be realized on SCM and upper computer of the control system. If serious, SCM will be halted, then the difficulty will be brought to the normal use. Therefore, the interference should be solved.
Solutions to power interference of stepper motor are as below:

  1. Install power filter to reduce the contamination of AC power.
  2. Reduce the the external interference in power line with the shielded line or the interference of power line in external world.
  3. Based on the principle of "single-point-earthing", earth the grounding of power filter and stepper driver PE (the baseboard of driver and chassis should be insulated.), control pulse and direction pulse DIR-outgoing lines of short circuit, motor earthing line, cable protecting cover between driver and motor and shielded wire of driver to the earthing rod on wall of chassis, and good contact should be realized.
  4. Lengthen the distance between control line, power line (L and N) and motor drive line (U, V and W) to avoid crossing, e.g. when dealing with the driver installation site of two drivers of the same chassis in the double-shaft system, put the nameplate of one driver forward and that of the other backward, and shorten the leads as far as possible when making structural arrangement.
Product reviews
Connection mode of three phase stepper motor
5
Mommy
Avatar
4/21/2021 9:51 PM
How the three phase internal winding of the stepper motor are connected together?
Was this review helpful? Yes No (0/0)
ATO Responded
The internal winding of three phase stepper motor is star connection.
Nema 42 stepper motor is as described
5
Drosy
Avatar
8/16/2022 1:52 AM
Nema 42 stepper motor is as described. It functions well overall, pin connections were good, no visible scratches or dents. I will recommend this nema 42 stepper motor to my friends.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews