25 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

$2,176.48
25 hp variable frequency drive with single phase 220V input, three phase 380V output, 37 amps, V/F control. Competitive price 18.5kW VFD designed for 3-phase asynchronous motor speed control.
SKU: GK3000-CS0185G
*
Free Shipping
Delivery date: 6-12 days

1-phase 220V to 3-phase 380V VFD for sales, 50Hz/ 60Hz input frequency, 0-400Hz output frequency, has RS485 communication port. 25 hp VFD can be used for constant torque loads and a phase converter.

Specification:

BasicsModelGK3000-CS0185G
Capacity25 hp (18.5 kW)
Shipping weight22 kg
Dimension530*320*235 mm
Installation size511*200 mm
I/O FeatureRated current37 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage (Optional)3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD)
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: How to run 3-phase 380V motor on 220V power supply?

When the variable frequency drive turns the three-phase motor on the occasion with only 220V household power supply, it has the features of slow starting and small starting impact on the household circuit. Generally, there are two main types of VFDs that drive a three-phase motor with 220 volt household voltage.

The first type is a three-phase 220V input and 220V output VFD. When this type of VFD drives a three-phase 380V motor, it generally uses a 380V star connection for a relatively low-power motor. When using a three-phase 220V output VFD , change the connection of the motor to a delta connection. The motor can be driven normally.

The second type is the VFD whose input is 220V and output is three-phase 380V, which is suitable for slightly larger three-phase motors. The motor itself is a 380V delta connection, so the connection can no longer be modified. Therefore, the motor can no longer use the modified connection to reduce the voltage, and can only use the VFD with a three-phase 380V output. When using this kind of variable frequency drive, the problem of on-site power supply capacity is mainly considered, because the motor power is larger, the input current should also be larger. The connection method is very simple, and the motor does not require special connection changes.

In this video, ATO will show you the vfd basic troubleshooting guide.

4-20mA speed control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Can you recommend the VFD I need based on my needs?
5
Genot
Avatar
8/20/2021 12:14 AM
I have a 2 hp, 3ph motor I would like to have speed control on. I am single phase 220 input. My motor draws 10 amps at 60 hz. What vfd do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
If your motor is 3-phase, 10A, 220V, and your supply is 1-phase, 220V, then recommended drive model: GK3000-2S0037, 5hp capacity.
Can you recommend the VFD I need based on my needs?
5
Abenet
Avatar
1/21/2026 12:24 PM
I have 3-phase induction motor, rated power 13kw, voltage 220 / 380 V (Δ / Y),Rated current 44 / 25 A , 50 Hz,  Speed 1460 rpm (4-pole motor) , Efficiency 88.5 % , What VFD do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
If your power supply is single-phase 220V, I recommend a 15kW VFD with single-phase 230V input and 3-phase 380V output: https://www.ato.com/20-hp-vfd-1-phase-220v-to-3-phase-380v
If your power supply is 3-phase 380V, I recommend a 3-phase 380V 15kW VFD: https://www.ato.com/20hp-vfd
If your power supply uses other voltages, please let us know.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1-phase 220V to 3-phase 380V VFD for sales, 50Hz/ 60Hz input frequency, 0-400Hz output frequency, has RS485 communication port. 25 hp VFD can be used for constant torque loads and a phase converter.

Specification:

BasicsModelGK3000-CS0185G
Capacity25 hp (18.5 kW)
Shipping weight22 kg
Dimension530*320*235 mm
Installation size511*200 mm
I/O FeatureRated current37 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage (Optional)3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD)
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: How to run 3-phase 380V motor on 220V power supply?

When the variable frequency drive turns the three-phase motor on the occasion with only 220V household power supply, it has the features of slow starting and small starting impact on the household circuit. Generally, there are two main types of VFDs that drive a three-phase motor with 220 volt household voltage.

The first type is a three-phase 220V input and 220V output VFD. When this type of VFD drives a three-phase 380V motor, it generally uses a 380V star connection for a relatively low-power motor. When using a three-phase 220V output VFD , change the connection of the motor to a delta connection. The motor can be driven normally.

The second type is the VFD whose input is 220V and output is three-phase 380V, which is suitable for slightly larger three-phase motors. The motor itself is a 380V delta connection, so the connection can no longer be modified. Therefore, the motor can no longer use the modified connection to reduce the voltage, and can only use the VFD with a three-phase 380V output. When using this kind of variable frequency drive, the problem of on-site power supply capacity is mainly considered, because the motor power is larger, the input current should also be larger. The connection method is very simple, and the motor does not require special connection changes.

Product reviews
Can you recommend the VFD I need based on my needs?
5
Genot
Avatar
8/20/2021 12:14 AM
I have a 2 hp, 3ph motor I would like to have speed control on. I am single phase 220 input. My motor draws 10 amps at 60 hz. What vfd do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
If your motor is 3-phase, 10A, 220V, and your supply is 1-phase, 220V, then recommended drive model: GK3000-2S0037, 5hp capacity.
Can you recommend the VFD I need based on my needs?
5
Abenet
Avatar
1/21/2026 12:24 PM
I have 3-phase induction motor, rated power 13kw, voltage 220 / 380 V (Δ / Y),Rated current 44 / 25 A , 50 Hz,  Speed 1460 rpm (4-pole motor) , Efficiency 88.5 % , What VFD do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
If your power supply is single-phase 220V, I recommend a 15kW VFD with single-phase 230V input and 3-phase 380V output: https://www.ato.com/20-hp-vfd-1-phase-220v-to-3-phase-380v
If your power supply is 3-phase 380V, I recommend a 3-phase 380V 15kW VFD: https://www.ato.com/20hp-vfd
If your power supply uses other voltages, please let us know.
Only registered users can write reviews
Customers who bought this item also bought

1 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0007
$159.32
1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.

2 Pole Molded Case Circuit Breaker, 20A/ 30A/ 40A/ 50A to 100A

ATO-MCCB-1002P
$76.98
2 pole molded case circuit breaker with 20A/ 30A/ 40A/ 50A, max. current 100 amp for selection, rated operating voltage 400V, rated insulated voltage 800 volt. The molded case breaker is suitable for conversion of line and infrequent starting motor.