10hp 7.5kW single phase output variable frequency drive, 1 phase 220V - 240V input, 1 phase 0 - 220V output, specialized designed for 1 phase induction motor.
Specification:
| Basics | Model | GK3000-1S0075 |
| Capacity | 10 hp (7.5 kW) | |
| Shipping weight | 8 kg | |
| Dimension | 330*200*200 mm | |
| I/O Feature | Rated current | 45 A |
| Input voltage | single phase AC 220V±15% | |
| Input frequency | 47~63Hz | |
| Output voltage | 0~rated input voltage | |
| Output frequency | 0~1000Hz | |
| Over load capacity | 150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s | |
| Control Features | Control mode | V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC) |
| Operation command mode | Keypad control, Terminal control, Serial communication control | |
| Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
| Start frequency | 0.40Hz~20.00Hz | |
| Speed adjustment range | 1:50 | |
| Carrier frequency | 1.0-16.0kHz, automatically adjusted according to temperature and load characteristics | |
| Frequency accuracy | Digital setting: 0.01Hz Analog setting: Maximum frequency * 0.05% | |
| Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% | |
| V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
| Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |
| Jog operation | Jog operation frequency: 0.0Hz~maximum frequency Jog acceleration/deceleration time: 0.1s~3600.0s | |
| Simple PLC & multi-step speed operation | It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. | |
| Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
| Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
| Control Function | Common DC bus | Common DC bus for several VFDs, energy balanced automatically |
| Torque control | Torque control without PG | |
| Torque limit | "Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process | |
| Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
| Timing/length/counting control | Timing/length/counting control function | |
| Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
| Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function | |
| Input/output terminals | Input terminals | Programmable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI: AI1: 0~10V or 0/4~20mA A12: 0~10V or 0/4~20mA |
| Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output) 2 relay output 2 analog output: 0/4~20mA or 0~10V | |
| Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
| Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
| Multifunction key | QUICK/JOG key, can be used as multifunction key | |
| Environment | Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃). |
| Humidity | 90%RH or less (non-condensing) | |
| Altitude | ≤1000M: Output rated power, >1000M: Output derated | |
| Storage temperature | -20℃~60℃ |
Note:
- The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
- ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
- Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
- If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.
Tips: Commissioning of single phase VFD with PC
After the basic settings of VFD, it can be connected with PC for the whole system commissioning. Connect the control lines of the VFD with the PC, and change the VFD operation mode to terminal control. According to the requirements of the PC system, set the VFD receive frequency signal range to 0~5V or 0~10V, and set the sampling response speed of analog frequency signal. If additional monitor is required, select the analog output monitoring item and adjust the range of this monitoring item terminal.
Product reviews
Single phase output VFD operation
Mcclellan
3/25/2021 1:53 AM
I am interested in single phase output VFD. Can I run multiple fan motors on one drive?
Was this review helpful? (0/0)
Benefits of removing the motor capacitor
Sharon
3/29/2021 8:04 PM
What is the advantage of removing motor capacitors when installing your 1 phase variable frequency drive?
Was this review helpful? (0/0)
Use of single phase VFD
Kamryn
5/7/2021 7:00 PM
Can a single phase VFD work with a shaded pole AC motor?
Was this review helpful? (0/0)
I have a question about VFD for you
Laurilee
8/25/2021 12:33 AM
Can this single phase VFD be applied to any type of 1 phase motor? I have a 240VAC supply fan for an indoor air handling unit and would like to control the speed to values other than the 3 speed settings that are available from the motor taps.
Was this review helpful? (0/0)
Do you offer external potentiometer for external speed controls for your 1 phase drive?
Sonido
1/6/2022 11:12 PM
Do you offer external potentiometer for external speed controls for your 1 phase drive?
Was this review helpful? (0/0)
Single phase motor with no chance to re wire it
Santiago
1/25/2022 1:15 PM
Can i connect to a single phase motor of 7.5 HP that i can't remove the capacitors this model? Also what size of wire can the sockets support, cause i have a 4 AWG on the output for the motor.
Was this review helpful? (0/0)
The VFD does not drive the motor.
Vernon
7/27/2022 7:02 PM
I received this shipment last week in good condition. During installation yesterday, I can only get one of them to output a voltage and it works fine. The other one appears to work fine, but it does not output a voltage/current and there is no error or fault even though the display shows it ramping up and down - the current is always 0.00. All settings are exactly the same on both units. I thought it might be one of the filters that was bad, but even when the filter is bypassed, the VFD does not drive the motor.
Was this review helpful? (0/0)
About VFD setup
Paulo
4/4/2023 12:11 AM
I have a VFD, and I need to configure it to respond appropriately to an E-Stop activation. From reading the manual, I believe I need to set two input terminals, one to option 11 (External Stop Command) and another to option 13 (Inverter Running Prohibited). Are these the two correct settings I need to configure or do I not need one of them or do I need to configure additional/other settings? I have successfully activated the external stop command, but do not know how to activate the "Inverter Running Prohibited" option. How do I activate this setting? Do I close the connection from this input terminal to COM (or GND) or do I need to connect it to an external positive voltage source (5V, 12V, or 24V)? To activate this setting, is it a momentary connection (like it is to activate the external stop command) or does it require a continuous connection for the duration the VFD needs to be prohibited from running. To exit this state (to be able to run the VFD again), does the VFD need to be reset, power cycled, or will simply opening the connection be sufficient?
Was this review helpful? (0/0)
How to read the Inverter Fault when OC1 is configured to output it?
Colleen
4/5/2023 8:17 PM
I got the e-stop button wiring figured out. I tried to do both a terminal stop command and a VFD Run Prohibit, but the spindle would just coast to a stop. I then disconnected the VFD Run Prohibit and it did what I needed. As a bonus, since the estop button is latching, stop command is continuously being applied, thus preventing the spindle from being restarted until the estop is deactivated. The only thing I haven't figured out is how to read the inverter fault when OC1 is configured to output it. There does not seem like enough voltage across the terminals to be able to activate a LED nor to energize a relay. How do I read the inverter's faults?
Was this review helpful? (0/0)
I have some questions
Lilma
1/23/2025 2:00 AM
Would it work better to bypass the start winding capacitor and centrifugal switch and just have the start and run winding in the circuit?
If I leave the start winding capacitor and centrifugal switch in the circuit does the drive function all right with the centrifugal switch?
How do I program the led display on the drive so I can toggle (using the double arrow button) between drive output parameters such as frequency, amps, voltage, speed? There is a P7.02 parameter setting but that appears to me that is for RS485 communication hexadecimal input.
With the CI input (4 to 20 ma) can I have an inverse function so that when the 4 to 20 ma input increases the VFD frequency output decreases?
If I leave the start winding capacitor and centrifugal switch in the circuit does the drive function all right with the centrifugal switch?
How do I program the led display on the drive so I can toggle (using the double arrow button) between drive output parameters such as frequency, amps, voltage, speed? There is a P7.02 parameter setting but that appears to me that is for RS485 communication hexadecimal input.
With the CI input (4 to 20 ma) can I have an inverse function so that when the 4 to 20 ma input increases the VFD frequency output decreases?
Was this review helpful? (0/0)
60Hz source to supply 50Hz condenser unit of split-type Aircon
Ben
7/27/2025 3:57 AM
I intend to use this 10 hp (7.5 kW) VFD, Single Phase Input
Was this review helpful? (0/0)
60Hz source to supply 50Hz condenser unit motors
Ben
7/27/2025 4:06 AM
I intend to use this 10 hp (7.5 kW) VFD, Single Phase Input and output, to power our HVAC outdoor unit compressor and fan rated at 220V 50HZ. Here in Saudi Arabia line voltage is 220V at 60HZ. Is this feasible? Thanks.
Was this review helpful? (0/0)