1/2 hp (400W) 3-Phase AC Gear Motor, Ratio 3~100

$568.15
Low rpm 3-phase AC gear motor has 0.5 hp (400W) working power, combined with an optional 90V brake for power cutting, gear ratio range from 3:1~100:1, torque 0.6~23 kg.m, rated voltage 110V/220V/380V, supporting horizontal and vertical installation, low price.
SKU: ATO-GEAR-HV400
*
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

1/2 hp (400 watt) 3-phase gear motor with excellent performance and good price, gear ratio selected in 3~100:1, power supply is available in single phase and 3-phase 110V/220V/380V. The gear reduction motor can cut power off easily when it connects with a brake.

Basic Specification

ModelATO-CH22-400 (Ratio:3~10)/ ATO-CH28-400 (Ratio:15~90)/ATO-CH32-400 (Ratio:100~200)
Rated Power400W (1/2 hp)
Rated VoltageSingle-phase 110V, 50/60Hz
Single-phase 220V, 50/60Hz
3-phase 220V, 50/60Hz
3-phase 380-415V, 50/60Hz
Gear Ratio3:1/ 5:1/ 10:1/ 15:1/ 20:1/ 25:1/ 30:1/ 40:1/ 45:1/ 50:1/ 60:1/ 70:1/ 80:1/ 90:1/ 100:1
Working Efficiency75%
Insulation GradeClass B, Class F can be customized
Protection GradeIP54
DutyContinuous running
Working EnvironmentTemperature 10℃~+40℃
Humidity ≤90%
Pole4P
Rated Speed1400RPM
Working Height≤1000m
StandardGB755/IEC-60034
PDFDownload Attachments400W 3 Phase AC Gear Motor Datasheet

Terminal Box Direction (From Output Shaft)

Terminal Box Direction of 3-Phase AC Gear Motor, Horizontal/vertical

AC Gear Motor Standard Installation

  • All the ATO 3-phase AC gear motors are suitable for this installation method, as shown in the following diagram.
  • In the diagram, Q1, Q4, Q7, Q8 are the standard types of oil hole direction. If you need the air hole be on a special position, please contact us to modify the air hole direction.
  • In actual use, it is recommended to pull out the oil plug in the air hole to balance the pressure in gearbox.

Air hole direction of 3-Phase AC Gear Motor, Horizontal/vertical

Details

400W AC Gear Motor Details

Tips: How to consider load conditions for 3-phase AC gear motor?

Load Calculation PrecautionsCalculation Example
Prime MotorConveyor Load ClassificationDaily Usage TimeT3 = T2 x K
= 5.28 x 1.26 = 6.6 kgf.m
0.50 hr2 hr8-10 hr10-24 hr
Electric MotorUniform0.800.901.001.25
Medium Shock0.901.001.251.50
Heavy Shock1.001.251.501.75
Corrective Torque = gear motor shaft torque x conefficient

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

Product reviews
Powerful AC gear motor
5
Wythe
Avatar
7/18/2021 9:06 PM
Does the motor heating up need to be dealt with?
Was this review helpful? Yes No (0/0)
ATO Responded
During everyday use, it is a relatively common phenomenon for a 3-phase AC gear motor to run overheated. However, if this problem is not paid great attention to, it will shorten the service life of the gear motor. If you meet this situation, you should first analyze the causes carefully, and then take a scientific solution.
1. Excessive power supply voltage will cause the temperature to be increased. You can install a suitable power regulator.
2. Low power supply voltage will also cause the situation of gear motor heating. It is necessary to increase the voltage of the power supply, to make it reach the rated requirements.
3. The core fault will lead to iron consumption damage and heat. This will need to check the core and eliminate the core fault.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1/2 hp (400 watt) 3-phase gear motor with excellent performance and good price, gear ratio selected in 3~100:1, power supply is available in single phase and 3-phase 110V/220V/380V. The gear reduction motor can cut power off easily when it connects with a brake.

Basic Specification

ModelATO-CH22-400 (Ratio:3~10)/ ATO-CH28-400 (Ratio:15~90)/ATO-CH32-400 (Ratio:100~200)
Rated Power400W (1/2 hp)
Rated VoltageSingle-phase 110V, 50/60Hz
Single-phase 220V, 50/60Hz
3-phase 220V, 50/60Hz
3-phase 380-415V, 50/60Hz
Gear Ratio3:1/ 5:1/ 10:1/ 15:1/ 20:1/ 25:1/ 30:1/ 40:1/ 45:1/ 50:1/ 60:1/ 70:1/ 80:1/ 90:1/ 100:1
Working Efficiency75%
Insulation GradeClass B, Class F can be customized
Protection GradeIP54
DutyContinuous running
Working EnvironmentTemperature 10℃~+40℃
Humidity ≤90%
Pole4P
Rated Speed1400RPM
Working Height≤1000m
StandardGB755/IEC-60034
PDFDownload Attachments400W 3 Phase AC Gear Motor Datasheet

Terminal Box Direction (From Output Shaft)

Terminal Box Direction of 3-Phase AC Gear Motor, Horizontal/vertical

AC Gear Motor Standard Installation

  • All the ATO 3-phase AC gear motors are suitable for this installation method, as shown in the following diagram.
  • In the diagram, Q1, Q4, Q7, Q8 are the standard types of oil hole direction. If you need the air hole be on a special position, please contact us to modify the air hole direction.
  • In actual use, it is recommended to pull out the oil plug in the air hole to balance the pressure in gearbox.

Air hole direction of 3-Phase AC Gear Motor, Horizontal/vertical

Details

400W AC Gear Motor Details

Tips: How to consider load conditions for 3-phase AC gear motor?

Load Calculation PrecautionsCalculation Example
Prime MotorConveyor Load ClassificationDaily Usage TimeT3 = T2 x K
= 5.28 x 1.26 = 6.6 kgf.m
0.50 hr2 hr8-10 hr10-24 hr
Electric MotorUniform0.800.901.001.25
Medium Shock0.901.001.251.50
Heavy Shock1.001.251.501.75
Corrective Torque = gear motor shaft torque x conefficient
Product reviews
Powerful AC gear motor
5
Wythe
Avatar
7/18/2021 9:06 PM
Does the motor heating up need to be dealt with?
Was this review helpful? Yes No (0/0)
ATO Responded
During everyday use, it is a relatively common phenomenon for a 3-phase AC gear motor to run overheated. However, if this problem is not paid great attention to, it will shorten the service life of the gear motor. If you meet this situation, you should first analyze the causes carefully, and then take a scientific solution.
1. Excessive power supply voltage will cause the temperature to be increased. You can install a suitable power regulator.
2. Low power supply voltage will also cause the situation of gear motor heating. It is necessary to increase the voltage of the power supply, to make it reach the rated requirements.
3. The core fault will lead to iron consumption damage and heat. This will need to check the core and eliminate the core fault.
Only registered users can write reviews
Customers who bought this item also bought

1 hp (0.75 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0007G
$206.49
Favorable price 1 hp (0.75 kW) VFD, three phase 230V/400V/480V 50Hz/60Hz for selection, sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.

2 hp (1.5 kW) VFD, 3 Phase 240V, 415V, 480V

GK3000-4T0015G
$218.41
Cheap price 2 hp (1.5 kW) VFD, three phase 240V, 415V, 480V for choice, brand new sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.

Digital Rotary Torque Sensor, 0.1/5/300/1000 Nm to 10000 Nm

ATO-TQS-D03
$939.15
Digital rotary torque sensor with LCD display has the capacity range from 0.1 Nm/0.3 Nm/1 Nm/5 Nm/10 Nm/300 Nm/1000 Nm to 10000 Nm. LCD display can show torque, speed and power value at the same time. Dynamic torque sensor adopts two NSK shafts to ensure starting torque as low as 0.00001 Nm. Rotary torque transducer with 7 pin waterproof circular connector and 3m cable can measure both forward and reverse torque, and then output ±5V/0-10V/4-20mA/RS485 torque signal to PLC.