After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.
Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.
Tension and compression load cells have capacity range from 5kg, 20kg, 30kg, 100kg, 500kg, 1 ton to 7 ton. Strain gauge load cell capacity can be customized according to customer requirements.
Specification
| Model | ATO-LCS-DYLY-102 |
| Shipping Weight | 1~2kg |
| Capacity Range * | 1~500kg, 1~7 ton |
| Matched Display Controller | ATO-DDC5-CHB (Click it to the controller page) |
| Matched Transmitter | ATO-LCTR-OA (Click it to the transmitter page) |
| Accuracy | 0.03%F.S (linearity + hysteresis + repeatability) |
| Sensitivity | 2.0±0.05mV/V (Low range variations may differ) |
| Creep | ±0.03%F.S/30min |
| Zero Output | ±1%F.S |
| Temperature Effect on Zero | ±0.03%F.S/10℃ |
| Temperature Effect on Output | ±0.03%F.S/10℃ |
| Operating Temperature | -20℃~+65℃ (-4℉~+149℉) |
| Input Impedance | 350±20Ω |
| Output Impedance | 350±5Ω |
| Insulation Resistance | ≥5000MΩ |
| Safety Overload | 150%F.S |
| Bridge Voltage (excitation voltage) | DC 5-15V, suggest DC 10V |
| Material | Alloy steel |
| Protection Class | IP67 |
| Cable Length | 2m (<5ton), 5m (≥5ton) |
| Wiring | EXC+: Red, EXC-: Black, SIG+: Green, SIG-: White |
Feature

- Durable Alloy Steel: Made from 42CrMo alloy steel, offering high strength, corrosion resistance, and long-term durability.
- Tension and Compression Measurement: Supports both tension and compression measurements for versatile use.
- High-Precision Strain Gauge: Ensures stable and reliable performance with long-term accuracy.
- Waterproof Connector: Six-corner waterproof connector prevents cable pull-out and ensures stable data transmission.
- Easy Installation: Standard threaded holes for simple installation and wide system compatibility.
- Versatile Applications: Ideal for force measurement and weighing systems in industrial automation.
- IP66 Protection: Water and dust-resistant for reliable performance in harsh environments.
Dimension
| Capacity | Dimension (mm) | |||
| W | H | B | M1 | |
| 0~1kg | 60 | 58 | 12 | M6*1.25 |
| 2~30kg | 60 | 58 | 12 | M8*1.25 |
| 50~200kg | 70 | 64 | 20 | M12*1.75 |
| 300~500kg | 70 | 64 | 20 | M12*1.75 |
| 1 ton | 70 | 64 | 25 | M16*2 |
| 2~7 ton | 84 | 92 | 32 | M20*2.5 |

Wiring Method

Application Cases

Tips: Advantage of S type load cell
S type load cell is the most common sensor, has the function of measuring both tension and compression, small size, high accuracy, good measuring range and convenient installation. It is appropriate for crane scale, batching scale, electronic-mechanical scale, and other electronic force measuring and weighing systems.
2. Will the amplifier support up to four loadcell? With what resistance each?
3. And for what application do customers take for this product?
You have already informed me that the transverse load (limit is 100% of the full scale). But why it is 100% of the full scale? How can this load be mitted for the safe performance of the load cell? How are you mitigating the effect of transverse load? What is the working principle here?
If a load is being applied offset from the center axis. How are you mitigating the bending moment? Is there any tolerance for that? If that is the case, what is the working principle here?
Regarding the connection method. We will be using a signal conditioner which can provide excitation voltage of -12 V to 12 V. But the signal input port for the conditioner is BNC type. In that case which kind of converter should we use for the cables for your sensor? Can you provide me a suggestion, which kind of adapter is compatible with your sensor to convert it into a BNC port.
You can provide me the answer of the number 3 query 1st. Then you can send me the other queries later on.