100A DC Reversing Contactor, 2 pole, 12V/24V/48V

$126.46
Low cost reversing contacor with two interlocked contacts, to prevent the motor from running forwards and backwards simultaneously. 2 pole DC contactor with 2NO and 2NC (DPST-NO, DPST-NC) contact form, coil rated voltage with 12V/24V/48V DC for choice.
SKU: ATO-DCCON-R100
*
Free Shipping
Delivery date: 6-12 days

ATO ADC100 reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Features

  • 100 amps rated load current of contact circuit.
  • DPST-NO, DPST-NC contact form.
  • 12V, 24V, 48V DC coil rated voltage for selection.
  • Main contact voltage drop at 100A, not above 80mV.
  • Mechanical life up to 300 thousand times.

Specifications

BasicsModelATO-ADC100
Body Size100*63*101 mm
Weight990 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12V~60V DC
Contact Circuit Rated Load Current100 A
Contact Form2NO and 2NC
Starting Current≤4 A
Overload Current≤8 le
Coil Power≤8 W
Main Contact Voltage Drop at 100A Load≤80 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤20 ms
Drop-Out Time (N/O Contact to Close)≤10 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 30000 times
Mechanical Life300 thousand times
EnvironmentOperating Temperature-40℃~85℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram

dc reversing contactor circuit diagram

Installation Diagram (Unit: mm)

dc reversing contactor 100a dimensionTips: DC contactor working principle

When the contactor coil powers on, the coil current generates a magnetic field, which makes the static iron core to produce magnetic adhesion and then suck the moving iron core, thus driving the movable contact to move. Normally closed contact disconnects and normally open contact closes, the two are linked. When the coil powers on, magnetic adhesion disappears, the armature releases under the effect of retracting spring, thus restoring the contact: Normally open contact disconnects while the normally closed contact closes.
DC contactor should be used in the DC power loop, such as the DC oil pump. This motor is used to guarantee the oil supply of turbine system at the time of power outage, both of its main circuit and auxiliary circuit are DC, so is the contactor.

DC Reversing Contactor for DC Motor Forward/Reverse Control
The reversing type of DC contactor has been designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks. In this video, ATO will show you how to use a DC reversing contactor for the DC motor forward and reverse control.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Will buy 48V DC contactor again
5
Chuck
Avatar
11/29/2018 11:40 PM
I couldn't find 100A 2 pole dc contactor on the local auto parts, but I had a chance to find ATO.com and I believe there is I have been looking for dc contactor. Thanks for the reasonable price, a project is a perfect job.
Was this review helpful? Yes No (0/0)
I need the 3D CAD model of the contactor
5
Gabriel Isko
Avatar
11/4/2019 5:51 PM
Hi, I recently purchased one of your 100A DC reversing contactors for my application and I am in the process of designing a mechanical enclosure for my setup. I need the 3D CAD model of the contactor that I purchased to integrate into my system!
Was this review helpful? Yes No (0/0)
ATO Responded
OK, will send you by email.
Contactor works perfectly
5
C
Avatar
3/5/2020 9:21 PM
Used this to switch on the inverter for my car. So far so good, works perfectly. Great price as well. I'm giving this DC reversing contactor a 5-star rating.
Was this review helpful? Yes No (0/0)
Can the 100A DC reversing contactor handle continuous loads?
5
Michaela
Avatar
4/21/2021 9:07 PM
Will your 100A reversing DC contactor handle continious duty?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, 24/7.
Coil of 100A DC reversing contactor
5
Stefanv
Avatar
6/22/2021 1:48 AM
Your DC reversing contactor ATO-DCCON-R100: is each contact able to conduct 100amps? and if so am I supposed to energize only one coil at a time? The coils are both labelled "K" so it seems to imply that both coils should be energized at the same time?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, each contact able to conduct 100amps. But it has 2 coils for selection of positive and negative directions. The middle contact of the coil should be connected to the negative pole of the power supply, and the other ends of the coil are connected to the positive pole of the power supply. Only one coil is connected at a time.
Use time of 100A DC reversing contactor
5
Aloysus
Avatar
7/29/2021 1:20 AM
How long can the coils be energized for your 100A reversing contactor ATO-DCCON-R100?
Was this review helpful? Yes No (0/0)
ATO Responded
The conactor (ATO-DCCON-R100) coil working specification can be continuous or discontinuous mode, continuous use for 24 hours or longer without any problem, as long as you don't use it overloaded. And the electrical life will be 30000 times.
Does the 100A version have a similar setup to the 50A version?
5
June
Avatar
5/29/2022 9:56 PM
I ordered the following product in the subject line and was wondering if there was any documentation for wiring this specific contactor to a motor. I saw the video on the product site however that was for the 50A version, is it a similar setup for the 100A version? Please and thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is a similar setup for the 100A version, you can refer to that video to complete all the operation settings, note that your motor starting current should not exceed the contactor's rated continuous current of 100A.
Coil Current
5
Jason
Avatar
11/5/2025 3:02 PM
I am trying to use the 100 amp reversing contactor for a 53A 12VDC motor.  I want to wire two buttons to the contactor one for reverse and one for forward.  Would I wire one side of each button to the middle connector as a ground and then one wire from the buttons to each of the other connectors?  Also what is the current rating of the coil.  I want to wire in a fuse inline with the buttons as a safety feature.  Or would it better to add in a breaker inline with the motor main power?  Thanks,
Was this review helpful? Yes No (0/0)
ATO Responded
Two coils, K1 and K2, will operate differently when energized separately. However, they share a common terminal, which connects directly to the power supply. The other branch, not connected to the common terminal, can be used to connect your push-button switch, with the other end connected to the control power supply, allowing for independent control. Please design your control logic carefully. The coil control circuit (push-button control section) does not require a fuse. Whether your main circuit needs a circuit breaker is up to you.
Rated current
4
Picken
Avatar
11/18/2025 8:03 PM
What is the rated current of the coil? This will help me determine the appropriate amperage fuse to choose. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
The rated current of the 12V coil of the ATO-DCCON-R100 contactor is 0.5A.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO ADC100 reversing contactor is used to change the direction of rotation in alternating current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Features

  • 100 amps rated load current of contact circuit.
  • DPST-NO, DPST-NC contact form.
  • 12V, 24V, 48V DC coil rated voltage for selection.
  • Main contact voltage drop at 100A, not above 80mV.
  • Mechanical life up to 300 thousand times.

Specifications

BasicsModelATO-ADC100
Body Size100*63*101 mm
Weight990 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Rated Load Voltage12V~60V DC
Contact Circuit Rated Load Current100 A
Contact Form2NO and 2NC
Starting Current≤4 A
Overload Current≤8 le
Coil Power≤8 W
Main Contact Voltage Drop at 100A Load≤80 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤20 ms
Drop-Out Time (N/O Contact to Close)≤10 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 30000 times
Mechanical Life300 thousand times
EnvironmentOperating Temperature-40℃~85℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram

dc reversing contactor circuit diagram

Installation Diagram (Unit: mm)

dc reversing contactor 100a dimensionTips: DC contactor working principle

When the contactor coil powers on, the coil current generates a magnetic field, which makes the static iron core to produce magnetic adhesion and then suck the moving iron core, thus driving the movable contact to move. Normally closed contact disconnects and normally open contact closes, the two are linked. When the coil powers on, magnetic adhesion disappears, the armature releases under the effect of retracting spring, thus restoring the contact: Normally open contact disconnects while the normally closed contact closes.
DC contactor should be used in the DC power loop, such as the DC oil pump. This motor is used to guarantee the oil supply of turbine system at the time of power outage, both of its main circuit and auxiliary circuit are DC, so is the contactor.

Product reviews
Will buy 48V DC contactor again
5
Chuck
Avatar
11/29/2018 11:40 PM
I couldn't find 100A 2 pole dc contactor on the local auto parts, but I had a chance to find ATO.com and I believe there is I have been looking for dc contactor. Thanks for the reasonable price, a project is a perfect job.
Was this review helpful? Yes No (0/0)
I need the 3D CAD model of the contactor
5
Gabriel Isko
Avatar
11/4/2019 5:51 PM
Hi, I recently purchased one of your 100A DC reversing contactors for my application and I am in the process of designing a mechanical enclosure for my setup. I need the 3D CAD model of the contactor that I purchased to integrate into my system!
Was this review helpful? Yes No (0/0)
ATO Responded
OK, will send you by email.
Contactor works perfectly
5
C
Avatar
3/5/2020 9:21 PM
Used this to switch on the inverter for my car. So far so good, works perfectly. Great price as well. I'm giving this DC reversing contactor a 5-star rating.
Was this review helpful? Yes No (0/0)
Can the 100A DC reversing contactor handle continuous loads?
5
Michaela
Avatar
4/21/2021 9:07 PM
Will your 100A reversing DC contactor handle continious duty?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, 24/7.
Coil of 100A DC reversing contactor
5
Stefanv
Avatar
6/22/2021 1:48 AM
Your DC reversing contactor ATO-DCCON-R100: is each contact able to conduct 100amps? and if so am I supposed to energize only one coil at a time? The coils are both labelled "K" so it seems to imply that both coils should be energized at the same time?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, each contact able to conduct 100amps. But it has 2 coils for selection of positive and negative directions. The middle contact of the coil should be connected to the negative pole of the power supply, and the other ends of the coil are connected to the positive pole of the power supply. Only one coil is connected at a time.
Use time of 100A DC reversing contactor
5
Aloysus
Avatar
7/29/2021 1:20 AM
How long can the coils be energized for your 100A reversing contactor ATO-DCCON-R100?
Was this review helpful? Yes No (0/0)
ATO Responded
The conactor (ATO-DCCON-R100) coil working specification can be continuous or discontinuous mode, continuous use for 24 hours or longer without any problem, as long as you don't use it overloaded. And the electrical life will be 30000 times.
Does the 100A version have a similar setup to the 50A version?
5
June
Avatar
5/29/2022 9:56 PM
I ordered the following product in the subject line and was wondering if there was any documentation for wiring this specific contactor to a motor. I saw the video on the product site however that was for the 50A version, is it a similar setup for the 100A version? Please and thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is a similar setup for the 100A version, you can refer to that video to complete all the operation settings, note that your motor starting current should not exceed the contactor's rated continuous current of 100A.
Coil Current
5
Jason
Avatar
11/5/2025 3:02 PM
I am trying to use the 100 amp reversing contactor for a 53A 12VDC motor.  I want to wire two buttons to the contactor one for reverse and one for forward.  Would I wire one side of each button to the middle connector as a ground and then one wire from the buttons to each of the other connectors?  Also what is the current rating of the coil.  I want to wire in a fuse inline with the buttons as a safety feature.  Or would it better to add in a breaker inline with the motor main power?  Thanks,
Was this review helpful? Yes No (0/0)
ATO Responded
Two coils, K1 and K2, will operate differently when energized separately. However, they share a common terminal, which connects directly to the power supply. The other branch, not connected to the common terminal, can be used to connect your push-button switch, with the other end connected to the control power supply, allowing for independent control. Please design your control logic carefully. The coil control circuit (push-button control section) does not require a fuse. Whether your main circuit needs a circuit breaker is up to you.
Rated current
4
Picken
Avatar
11/18/2025 8:03 PM
What is the rated current of the coil? This will help me determine the appropriate amperage fuse to choose. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
The rated current of the 12V coil of the ATO-DCCON-R100 contactor is 0.5A.
Only registered users can write reviews
Customers who bought this item also bought

100A High Voltage DC Contactor, 12V/24V coil

ATO-DCCON-HV100
$118.92
The ATO-ADH100 contactor is specially design to meet the requirements of high voltage DC switching applications. Available with 12V or 24V coils, SPST-NO contact form, 100A rated load current of contact circuit, DC 12-900V rated load voltage.

50A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R50
$74.31
Two pole DC reversing contacor with 2 sets of switching contacts, 2NO and 2NC form, 50 amps rated load current of contact circuit, coil rated voltage with 12V/24V/48V DC for selection. Cheap price and manufacturer direct sale.

125A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R125
$132.41
Excellent conductivity reversing contacor is designed for demanding forward/reverse control of the motors. 2 pole DC contactor with 12V/24V/48V coil, 2NO and 2NC contact form, and is available with two optional auxiliary contacts.

200A DC Contactor, 12V/24V/48V

ATO-DCCON-C200
$121.65
This 200 amps contactor is available in coil voltage 12V, 24V, 48V, continuous operating duty, normally open (NO) or normally closed (NC) contact form, high quality DC contactor with high-performance quality, low cost and manufacturer direct sale.

DC-DC Buck Converter, 24V to 12V

ATO-DCDC-2412
$102.58
24V to 12V mini DC-DC buck converter series is a compact size high reliability power converter with low price. This buck module features wide input voltage 18V to 36V, wide range power from 18 watts to 1200 watts, low power consumption. Industry grade step down converter, efficiency up to 97%.