200A DC Contactor, 12V/24V/48V

$121.65
This 200 amps contactor is available in coil voltage 12V, 24V, 48V, continuous operating duty, normally open (NO) or normally closed (NC) contact form, high quality DC contactor with high-performance quality, low cost and manufacturer direct sale.
SKU: ATO-DCCON-C200
*
Free Shipping
Delivery date: 6-12 days

The 200A DC contactor has NO or NC main contact and has been designed for direct current loads, particularly for electric vehicles, telecommunication equipment, car batteries, trains, ships, electronic control systems.

Features

  • The DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 200 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 200A DC contactors are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJB200A-DATO-SZJ200A
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)6V, 12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V, 220V6V, 12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤60V
Contact 48V Circuit Rated Load Current (DC-1)200A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%≤40%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms15ms
Power-off Release Time20ms10ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)1000A/5ms at 48V DC
Coil Power Consumption (W)7-15Start: 120-170, Hold: 4-10
Coil Temperature Rise (K)≤80≤80
Terminal Temperature Rise (K)≤65
Electrical Life20000 times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver Alloy
Load Terminal TypeM8 Screw
Coil Terminal TypeM4 Screw
Auxiliary Contact Rated Load (Optional)2A/48V DC, 5A/24V DC, One Open and One Closed
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

200A load characteristic curve

Installation Dimension Diagram

200A DC contactor installation dimension drawing

Wiring Diagram & Temperature Rise Curve Graph

200A DC contactor wiring

200A DC contactor temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯9.0 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: DC contactor's coil adopts a series duplex winding

In order to reduce the power consumption of the coils and extend the service life, a large capacity DC contactor coil usually adopts a series duplex winding. A break contact of the contactor is parallel to the holding coil. When the coil powers on, the holding coil is shorted by the break contact, which makes the starting coil to obtain a large current and suction force. After the contactor acts, the starting coil and holding coil keep powering on in a series connection. Due to the constant voltage, the current is small, but the armature can still be kept in, thus saving the power.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Can you provide DC contactors with 2 auxillary points?
5
Hamid
Avatar
4/9/2020 2:48 AM
For your 200A DC contatcor, it proivde 1 auxillary point at the web site, can you provide 2 auxillary points?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, but the price will be a bit more for 2 auxiliary.
Panel mount accessories
5
Lorena
Avatar
3/30/2026 12:42 AM
I am looking for panel mount accessories for the ATO-DCCON-C100 and C200.
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-DCCON-C200 has four mounting options. Which panel mount option do you prefer?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The 200A DC contactor has NO or NC main contact and has been designed for direct current loads, particularly for electric vehicles, telecommunication equipment, car batteries, trains, ships, electronic control systems.

Features

  • The DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 200 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 200A DC contactors are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJB200A-DATO-SZJ200A
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)6V, 12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V, 220V6V, 12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤60V
Contact 48V Circuit Rated Load Current (DC-1)200A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%≤40%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms15ms
Power-off Release Time20ms10ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)1000A/5ms at 48V DC
Coil Power Consumption (W)7-15Start: 120-170, Hold: 4-10
Coil Temperature Rise (K)≤80≤80
Terminal Temperature Rise (K)≤65
Electrical Life20000 times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver Alloy
Load Terminal TypeM8 Screw
Coil Terminal TypeM4 Screw
Auxiliary Contact Rated Load (Optional)2A/48V DC, 5A/24V DC, One Open and One Closed
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

200A load characteristic curve

Installation Dimension Diagram

200A DC contactor installation dimension drawing

Wiring Diagram & Temperature Rise Curve Graph

200A DC contactor wiring

200A DC contactor temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯9.0 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: DC contactor's coil adopts a series duplex winding

In order to reduce the power consumption of the coils and extend the service life, a large capacity DC contactor coil usually adopts a series duplex winding. A break contact of the contactor is parallel to the holding coil. When the coil powers on, the holding coil is shorted by the break contact, which makes the starting coil to obtain a large current and suction force. After the contactor acts, the starting coil and holding coil keep powering on in a series connection. Due to the constant voltage, the current is small, but the armature can still be kept in, thus saving the power.

Product reviews
Can you provide DC contactors with 2 auxillary points?
5
Hamid
Avatar
4/9/2020 2:48 AM
For your 200A DC contatcor, it proivde 1 auxillary point at the web site, can you provide 2 auxillary points?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, but the price will be a bit more for 2 auxiliary.
Panel mount accessories
5
Lorena
Avatar
3/30/2026 12:42 AM
I am looking for panel mount accessories for the ATO-DCCON-C100 and C200.
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-DCCON-C200 has four mounting options. Which panel mount option do you prefer?
Only registered users can write reviews
Customers who bought this item also bought

600A DC Contactor, 12V/24V/48V

ATO-DCCON-C600
$185.32
High current contactor, designed for DC loads, contact circuit rated load current is 600A, normally open (NO) or normally closed (NC) contact form which has excellent conductivity. Single pole contactor, cheap price and manufacturer direct sale.

100A DC Contactor, 12V/24V/48V

ATO-DCCON-C100
$103.63
High performance 100A DC contactor with normally open or normally closed main contact type, and available with two optional auxiliary contacts. Coil rated voltage with 12V/24V/48V for selection, main contact voltage drop at 100A, not above 100mV.

50 amp 3/4 Pole DC Coil Contactor, 12V/24V/48V/220V Coil

ATO-DCCON-50A
$156.92
50A 3 or 4 pole AC contactor is an electrical switching device with DC control to control electric motors, lighting and other electrical loads at 12V, 24V, 36V, 48V, 110V, 220V coil rated voltage. Rated power up to 37 kW, contact form 3 NO or 2NO+2NC for your choices.

1500A DC Contactor, 12V/24V/48V

ATO-DCCON-C1500
$233.15
The coil voltage of this 1500A contactor is 12V DC contactor, 24V DC contactor, 48V DC contactor, etc. This DC contactor with a large current of 1500A is made of selected thermosetting BMC material and has no burning points. Wear-resistant, non-breaking and stable in performance.

100A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R100
$126.46
Low cost reversing contacor with two interlocked contacts, to prevent the motor from running forwards and backwards simultaneously. 2 pole DC contactor with 2NO and 2NC (DPST-NO, DPST-NC) contact form, coil rated voltage with 12V/24V/48V DC for choice.