50A DC Reversing Contactor, 2 pole, 12V/24V/48V

$74.31
Two pole DC reversing contacor with 2 sets of switching contacts, 2NO and 2NC form, 50 amps rated load current of contact circuit, coil rated voltage with 12V/24V/48V DC for selection. Cheap price and manufacturer direct sale.
SKU: ATO-DCCON-R50
*
Free Shipping
Delivery date: 6-12 days

The provided 50A DC reversing contactor with 2NO and 2NC contact type, coil voltage available in 12 volt, 24 volt, 48 volt. It is used to change the direction of rotation in direct current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Specifications

BasicsModelATO-ADC50
Body Size81*52*76 mm
Weight410 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Contact Circuit Rated Load Current50A
Contact Rated Load Voltage12V~60V DC
Contact Form2NO and 2NC
Starting Current≤4 A
Overload Current≤8 le
Coil Power≤8 W
Main Contact Voltage Drop at 50A Load≤80 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤20 ms
Drop-Out Time (N/O Contact to Close)≤10 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 30000 times
Mechanical Life300 thousand times
EnvironmentOperating Temperature-40℃~85℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram

dc reversing contactor circuit diagramInstallation Diagram (Unit: mm)
dc reversing contactor 50a dimension

Details

50A DC Reversing Contactor Details

Tips: Short circuit of the contactor, how to solve?

Possible causes of the fault:

  • The contactor works in the environment of damp, dust, steam, or corrosive gases.
  • The arc chute damages or falls, load short leads to the contact short of the contactor.
  • Incorrect operation of the positive and reverse contactor, as well as unreliable interlocking, make two contactors to pull in at a same time when reversing.

Maintenance method:

  1. Improve the working environment and keep clean.
  2. Match an arc-extinguishing equipment again.
  3. Handle the load short failure.
  4. Recheck the contactor's interlocking circuit, change the operation mode.

DC Reversing Contactor for DC Motor Forward/Reverse Control
The reversing type of DC contactor has been designed for direct current loads, particularly motors as used on electric vehicles such as industrial trucks. In this video, ATO will show you how to use a DC reversing contactor for the DC motor forward and reverse control.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
A good reversing contactor
5
Marvin
Avatar
5/30/2018 7:34 PM
This 50A contactor is a good reversing contactor, I bought to replace of my original Polaris winch part, easy to install, so far it is working great.
Was this review helpful? Yes No (0/0)
Great little reversing DC contactor works exactly as represented
5
Shawn Dalden
Avatar
10/9/2018 7:11 PM
Great little reversing DC contactor works exactly as represented and is an excellent value for the price! Product was delivered on time and was very well packed.
Was this review helpful? Yes No (0/0)
How to test your DC reversing contactor?
5
Kathleen
Avatar
10/21/2019 6:52 PM
Can you send me instructions on how to test your DC reversing contactor on my site before installation?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, will send you the instructions, and you can see videos on our YouTube channel. https://www.youtube.com/c/ATOcom.
Coil functionality
4
Dorian
Avatar
6/19/2025 7:35 PM
I am working on a project that involves a linear actuator that uses 10 amps and 24 volts DC. I would like to use your SKU: ATO-DCCON-R50. I would like to know if the contacts in this unit interlock so that if I use the buttons on the system and pressing the "up" button activates one coil and pressing the "down" button activates the other coil, will it also activate the other coil and contacts?
Was this review helpful? Yes No (0/0)
ATO Responded
Our contactor does not have the contact interlock feature you mentioned, it only controls one coil and the other coil is not activated.
Some Questions
5
Pena
Avatar
12/21/2025 7:28 PM
For the 50A DC commutator contactor ATO-DCCON-R50, would you recommend connecting two freewheeling diodes to its coil contacts (forward and reverse) to prevent current/voltage spikes during motor forward/reverse switching? If so, could you recommend suitable freewheeling diode models and/or specifications? Furthermore, could you provide vibration/shock data for this component? Does this component meet MIL-STD-810G vibration/shock requirements? If not, could you provide alternative components suitable for harsh environments that meet MIL-STD-810G requirements?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Installing freewheeling diodes is recommended; this is better for protecting circuit stability.
2. Our product has a shock stability of 20g and a strength of 50g. This component does not meet MIL-STD-810G vibration/shock requirements. Sorry, there are currently no products that meet this standard.
Overload protection function
5
Borina
Avatar
1/19/2026 12:17 AM
Does the ATO-DCCON-R50 include DC motor overload protection? Can you recommend an overload relay that can be used with the ATO-DCCON-R50? Recommended terminal block sizes: -,  , M1, and M2. Recommended female connector sizes for coil connections: 0V, C1, and C2.
Was this review helpful? Yes No (0/0)
ATO Responded
1. This DC commutator contactor does not include DC motor overload protection.
2. Unfortunately, our overload relays are currently only available for AC applications; there is no DC version.
3. For the main circuit (-, +, M1, and M2), please select the appropriate wire gauge according to the current.
4. For coil connections (0V, C1, and C2), 6.3mm spring clips are typically used for coil insertion connections, and M3 studs can be used for screw connections.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The provided 50A DC reversing contactor with 2NO and 2NC contact type, coil voltage available in 12 volt, 24 volt, 48 volt. It is used to change the direction of rotation in direct current motors, start them gently and to monitor their load. Widely used in auto electric winch, telecommunication equiment, engineering machinery and other electric control system.

Specifications

BasicsModelATO-ADC50
Body Size81*52*76 mm
Weight410 g
Technical ParametersCoil Rated Voltage12V/24V/48V
Contact Circuit Rated Load Current50A
Contact Rated Load Voltage12V~60V DC
Contact Form2NO and 2NC
Starting Current≤4 A
Overload Current≤8 le
Coil Power≤8 W
Main Contact Voltage Drop at 50A Load≤80 mV
The Allowed Range of Coil Voltage±20%
Pull-In Time (N/O Contacts to Open)≤20 ms
Drop-Out Time (N/O Contact to Close)≤10 ms
Insulation Resistance≥50 MΩ
Dielectric Withstanding Voltage50Hz/60Hz 1500VAC/Min
Electric LifeContinuous 30000 times
Mechanical Life300 thousand times
EnvironmentOperating Temperature-40℃~85℃
Operating Humidity5~95% RH

DC Reversing Contactor Circuit Diagram

dc reversing contactor circuit diagramInstallation Diagram (Unit: mm)
dc reversing contactor 50a dimension

Details

50A DC Reversing Contactor Details

Tips: Short circuit of the contactor, how to solve?

Possible causes of the fault:

  • The contactor works in the environment of damp, dust, steam, or corrosive gases.
  • The arc chute damages or falls, load short leads to the contact short of the contactor.
  • Incorrect operation of the positive and reverse contactor, as well as unreliable interlocking, make two contactors to pull in at a same time when reversing.

Maintenance method:

  1. Improve the working environment and keep clean.
  2. Match an arc-extinguishing equipment again.
  3. Handle the load short failure.
  4. Recheck the contactor's interlocking circuit, change the operation mode.
Product reviews
A good reversing contactor
5
Marvin
Avatar
5/30/2018 7:34 PM
This 50A contactor is a good reversing contactor, I bought to replace of my original Polaris winch part, easy to install, so far it is working great.
Was this review helpful? Yes No (0/0)
Great little reversing DC contactor works exactly as represented
5
Shawn Dalden
Avatar
10/9/2018 7:11 PM
Great little reversing DC contactor works exactly as represented and is an excellent value for the price! Product was delivered on time and was very well packed.
Was this review helpful? Yes No (0/0)
How to test your DC reversing contactor?
5
Kathleen
Avatar
10/21/2019 6:52 PM
Can you send me instructions on how to test your DC reversing contactor on my site before installation?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, will send you the instructions, and you can see videos on our YouTube channel. https://www.youtube.com/c/ATOcom.
Coil functionality
4
Dorian
Avatar
6/19/2025 7:35 PM
I am working on a project that involves a linear actuator that uses 10 amps and 24 volts DC. I would like to use your SKU: ATO-DCCON-R50. I would like to know if the contacts in this unit interlock so that if I use the buttons on the system and pressing the "up" button activates one coil and pressing the "down" button activates the other coil, will it also activate the other coil and contacts?
Was this review helpful? Yes No (0/0)
ATO Responded
Our contactor does not have the contact interlock feature you mentioned, it only controls one coil and the other coil is not activated.
Some Questions
5
Pena
Avatar
12/21/2025 7:28 PM
For the 50A DC commutator contactor ATO-DCCON-R50, would you recommend connecting two freewheeling diodes to its coil contacts (forward and reverse) to prevent current/voltage spikes during motor forward/reverse switching? If so, could you recommend suitable freewheeling diode models and/or specifications? Furthermore, could you provide vibration/shock data for this component? Does this component meet MIL-STD-810G vibration/shock requirements? If not, could you provide alternative components suitable for harsh environments that meet MIL-STD-810G requirements?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Installing freewheeling diodes is recommended; this is better for protecting circuit stability.
2. Our product has a shock stability of 20g and a strength of 50g. This component does not meet MIL-STD-810G vibration/shock requirements. Sorry, there are currently no products that meet this standard.
Overload protection function
5
Borina
Avatar
1/19/2026 12:17 AM
Does the ATO-DCCON-R50 include DC motor overload protection? Can you recommend an overload relay that can be used with the ATO-DCCON-R50? Recommended terminal block sizes: -,  , M1, and M2. Recommended female connector sizes for coil connections: 0V, C1, and C2.
Was this review helpful? Yes No (0/0)
ATO Responded
1. This DC commutator contactor does not include DC motor overload protection.
2. Unfortunately, our overload relays are currently only available for AC applications; there is no DC version.
3. For the main circuit (-, +, M1, and M2), please select the appropriate wire gauge according to the current.
4. For coil connections (0V, C1, and C2), 6.3mm spring clips are typically used for coil insertion connections, and M3 studs can be used for screw connections.
Only registered users can write reviews
Customers who bought this item also bought

100A DC Reversing Contactor, 2 pole, 12V/24V/48V

ATO-DCCON-R100
$126.46
Low cost reversing contacor with two interlocked contacts, to prevent the motor from running forwards and backwards simultaneously. 2 pole DC contactor with 2NO and 2NC (DPST-NO, DPST-NC) contact form, coil rated voltage with 12V/24V/48V DC for choice.

DC Current Sensor 1mA/1A/5A/10A/100A to 800A

ATO-CUS-DC800
$85.56
DC current sensor has best cost performance, fast response, high accuracy, good stability, small size, light weight, DIN rail installation, widely used for DC current measurement of various occasions.

50A High Voltage DC Contactor, 12V/24V coil

ATO-DCCON-HV50
$111.85
High voltage DC contactor, normally open type (SPST-NO), 50 amps rated load current of contact circuit, available with 12V or 24V coils, the connection of contact and coil need to be nonpolarity. It is widely used in the DC high voltage field, such as electric car, wind power generation, DC power supply control system and so on.

50A DC Contactor, 12V/24V/48V

ATO-DCCON-C50
$102.61
High quality DC contactor with 12V, 24V, 36V and 48V coil voltage for choice, normally open or normally closed type, contact circuit rated load current of 50A, offers exceptional performance in an extremely small and lightweight device.

DC Voltage Monitoring Relay, Under/Over Voltage, 12V/24V/48V DC

ATO-MR-DVRD
$105.98
DC voltage monitoring relay with 2 C/O contacts (2 Form C or DPDT) provide protection for the equipment from undervoltage and overvoltage in DC circuit 12V, 24V, 36V or 48V, adjustable trip delay time, LED indicator for working state, DIN rail mounting, compact design, good quality and low price.