Vortex Flow Meter for Gas, Biogas/Air/Propane/Argon

$1,089.84
Selling low price vortex flow meter for gas. Vortex flow measurement natural gas, biogas, propane, air, argon, etc. The gas flow meter has available calibers DN15-DN200, available output signal 4~20mA, 0-5V, 0-10V, 1.6Mpa work pressure. Vortex flowmeter focus on flammable and explosive gas flow measurement, suitable for petroleum, chemical, gas supply industry.
SKU: ATO-FLOW-VFM
*
*
*
*
*
*
Free Shipping
Delivery date: 8-12 days

Affordable vortex flow meter is designed for measuring gas flow, including natural gas, biogas, propane, air, and argon. Vortex flow meter supports sizes from DN15 to DN200 and offers output signals like 4-20mA, 0-5V, and 0-10V. With a working pressure of 1.6 MPa, 1.5 accuracy class, vortex flow meter is ideal for measuring flammable and explosive gases in industries like petroleum, chemicals, and gas supply.

Specification

Nominal DiameterDN15-DN200
Output Signal4~20mA, 0-5V, 0-10V (optional)
Standard ConditionsP=101.325 kPa, T=293.15 K
Work Pressure1.6 Mpa
Operating ConditionsAmbient Temp: -20~80°C, Pressure: 86~106 kPa, Environment Temp: -30°C~65°C, Relative Humidity: 5%~95%
MaterialAluminum Alloy (Stainless steel 304 available, contact customer service)
Accuracy Class1.5
Range1:25
External Power SupplyA. +24VDC±15%, ripple<5%, suitable for 4~20mA output, alarm output, RS485 etc.
B. Internal: 1.2V 3.6V
Power ConsumptionA. External Power: <2W
B. Internal: Average power <1mW, continuous use for more than one year
Display FunctionA. Real-time display for temperature, pressure, flow, and alarm
B. Alarm outputs: Flow rise/fall, Temperature rise/fall
Explosion ProtectionEx db ⅡC T6 Gb
Protection GradeIP65
Electrical InterfaceInternal thread M20*1.5 (order before delivery notice)
Applicable MediumGaseous Media (Biogas, air, propane, argon, etc.)


Feature

Vortex flow meter for gas feature

  • Stable Durability and Long Life: The vortex type flow meter features an integrated design with no moving parts, ensuring high durability and resistance to wear, requiring minimal maintenance for long-term operation.
  • High-Performance Integrated Circuit: Equipped with high-quality integrated circuits, the product offers exceptional precision and strong functionality in a compact design.
  • Intelligent Anti-Vibration Technology: With advanced domestic anti-vibration technology, this gas flow meter effectively suppresses vibrations and pressure-induced signals, offering robust resistance to external disturbances.
  • Multiple Output Options with Clear Display: The vortex flow meter supports 4-20mA analog signal output and an RS485 interface, allowing for easy connection to computers and networks, with data transmission capabilities of up to 1.2 km.

Dimension (Unit:mm)

Vortex flow meter for gas size

Diameter (mm)Max Pressure (MPa)LHDKN-d
DN15416232095654-M12
DN204162325105754-M12
DN254182335115854-φ14
DN3242003501401004-φ18
DN4042343601501104-φ18
DN5042343651651254-φ18
DN651.62863901851454-φ18
DN801.63304052001608-φ18
DN1001.64104252201808-φ18
DN1251.65164502502108-φ18
DN1501.65854702852408-φ22
DN2001.669052534029512-φ22


Component Display

Vortex flow meter for gas component display

Application

Vortex flow meter application

Tips: what is the vortex flow meter working principle?

The flow sensor has a flow profile similar to that of a venturi (figure below). In the inlet side of a set of spiral guide vane, when the fluid into the flow sensor, the guide vane forcing the fluid to produce intense vortex flow. When the fluid enters the diffusion section, the vortex flow by the role of reflux, began to make the second rotation, the formation of gyroscopic vortex into the phenomenon. The feed frequency and flow size is proportional to the size of the fluid is not affected by the physical properties and density of the fluid, the detection element to measure the frequency of the second rotation of the fluid into the frequency can be obtained in a wide range of flow rate within a good degree of linearity.

Signal amplified by the preamplifier, filtering, shaping converted to a pulse signal proportional to the flow rate, and then with the temperature, pressure and other detection signals are sent to the microprocessor for the cumulative processing, and finally in the LCD display shows the results of the measurements (instantaneous flow rate, cumulative flow rate and temperature, pressure data).

Vortex flow meter working principle

Product reviews
Product Information
5
Lunes
Avatar
4/21/2026 1:54 AM
Please provide information and pricing for the following product: 1 unit – 3-inch automatic vaporization vortex mass flow meter and transmitter.
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our ATO-FLOW-VFM flow meter to determine if the option meets your requirements.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Affordable vortex flow meter is designed for measuring gas flow, including natural gas, biogas, propane, air, and argon. Vortex flow meter supports sizes from DN15 to DN200 and offers output signals like 4-20mA, 0-5V, and 0-10V. With a working pressure of 1.6 MPa, 1.5 accuracy class, vortex flow meter is ideal for measuring flammable and explosive gases in industries like petroleum, chemicals, and gas supply.

Specification

Nominal DiameterDN15-DN200
Output Signal4~20mA, 0-5V, 0-10V (optional)
Standard ConditionsP=101.325 kPa, T=293.15 K
Work Pressure1.6 Mpa
Operating ConditionsAmbient Temp: -20~80°C, Pressure: 86~106 kPa, Environment Temp: -30°C~65°C, Relative Humidity: 5%~95%
MaterialAluminum Alloy (Stainless steel 304 available, contact customer service)
Accuracy Class1.5
Range1:25
External Power SupplyA. +24VDC±15%, ripple<5%, suitable for 4~20mA output, alarm output, RS485 etc.
B. Internal: 1.2V 3.6V
Power ConsumptionA. External Power: <2W
B. Internal: Average power <1mW, continuous use for more than one year
Display FunctionA. Real-time display for temperature, pressure, flow, and alarm
B. Alarm outputs: Flow rise/fall, Temperature rise/fall
Explosion ProtectionEx db ⅡC T6 Gb
Protection GradeIP65
Electrical InterfaceInternal thread M20*1.5 (order before delivery notice)
Applicable MediumGaseous Media (Biogas, air, propane, argon, etc.)


Feature

Vortex flow meter for gas feature

  • Stable Durability and Long Life: The vortex type flow meter features an integrated design with no moving parts, ensuring high durability and resistance to wear, requiring minimal maintenance for long-term operation.
  • High-Performance Integrated Circuit: Equipped with high-quality integrated circuits, the product offers exceptional precision and strong functionality in a compact design.
  • Intelligent Anti-Vibration Technology: With advanced domestic anti-vibration technology, this gas flow meter effectively suppresses vibrations and pressure-induced signals, offering robust resistance to external disturbances.
  • Multiple Output Options with Clear Display: The vortex flow meter supports 4-20mA analog signal output and an RS485 interface, allowing for easy connection to computers and networks, with data transmission capabilities of up to 1.2 km.

Dimension (Unit:mm)

Vortex flow meter for gas size

Diameter (mm)Max Pressure (MPa)LHDKN-d
DN15416232095654-M12
DN204162325105754-M12
DN254182335115854-φ14
DN3242003501401004-φ18
DN4042343601501104-φ18
DN5042343651651254-φ18
DN651.62863901851454-φ18
DN801.63304052001608-φ18
DN1001.64104252201808-φ18
DN1251.65164502502108-φ18
DN1501.65854702852408-φ22
DN2001.669052534029512-φ22


Component Display

Vortex flow meter for gas component display

Application

Vortex flow meter application

Tips: what is the vortex flow meter working principle?

The flow sensor has a flow profile similar to that of a venturi (figure below). In the inlet side of a set of spiral guide vane, when the fluid into the flow sensor, the guide vane forcing the fluid to produce intense vortex flow. When the fluid enters the diffusion section, the vortex flow by the role of reflux, began to make the second rotation, the formation of gyroscopic vortex into the phenomenon. The feed frequency and flow size is proportional to the size of the fluid is not affected by the physical properties and density of the fluid, the detection element to measure the frequency of the second rotation of the fluid into the frequency can be obtained in a wide range of flow rate within a good degree of linearity.

Signal amplified by the preamplifier, filtering, shaping converted to a pulse signal proportional to the flow rate, and then with the temperature, pressure and other detection signals are sent to the microprocessor for the cumulative processing, and finally in the LCD display shows the results of the measurements (instantaneous flow rate, cumulative flow rate and temperature, pressure data).

Vortex flow meter working principle

Product reviews
Product Information
5
Lunes
Avatar
4/21/2026 1:54 AM
Please provide information and pricing for the following product: 1 unit – 3-inch automatic vaporization vortex mass flow meter and transmitter.
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our ATO-FLOW-VFM flow meter to determine if the option meets your requirements.
Only registered users can write reviews