B type thermocouple assembles with protection head and corundum thermowell, should use wooden case for packing. Its thermo wire diameter is Ф0.5mm. B type thermocouple has the best performence and longest life. It can directly measure the temperature in the range of 0~1600 ℃ in various production processes.
SKU: ATO-TC-BA
*
Free Shipping
Delivery date: 6-12 days

As a temperature sensor, thermocouple assembly is usually used with display instruments, recording instruments and signal conditioners.

Specification

1. Thermocouple temperature range chart

CategoryType of sensing elementRelationship between wire diameter and temperature
Thermo wire diameter (mm)Long-term temperature (℃)Short-tem temperature (℃)
Platinum Rhodium 30 - Platinum Rhodium 6B typeΦ0.516001800
Platinum Rhodium 13 - PlatinumR typeΦ0.513001600
Platinum Rhodium 10 - PlatinumS typeΦ0.513001600
Nickel chromium silicon - Nickel silicon magnesiumN typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Nickel siliconK typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Copper nickelE typeΦ0.3350450
Φ0.5450550
Φ0.8, Φ1.0550650
Φ1.2, Φ1.6650750
Φ2.0, Φ2.5750900
Iron - ConstantanJ typeΦ0.3, Φ0.5300400
Φ0.8, Φ1.0400500
Φ1.2, Φ1.6500600
Φ2.0, Φ2.5600750
Copper - Copper nickelT typeΦ0.2150200
Φ0.3, Φ0.5200250
Φ1.0250300
Φ1.6350400

2. Thermowell application temperature range chart

Thermowell materialLong-term temperatureShort-term temperature
Corundum CT116001800
High alumina CT213001600
Nickel base wrought superalloys 3YC5213001350
Nickel base wrought superalloys GH303912501320
Nickel base superalloys GH303012001250
Heat resistant stainless steel 2Cr25Ni2012001250
Silicon carbide11001150
Stainless steel 316L900950
Stainless steel 1Cr18Ni9Ti800900

3. Thermowell installing form (unit: mm)
B type thermocouple installing form
4. Selection chart

Total length of thermowell (L or L*L1)Branch numberThermowell installing form
Protection head form
Diameter and material of thermowell
300~2150mm (for I1, I2, I3, I4);
500*500mm, 750*500mm, 750*750mm (for I5);
225~450mm (for I6)
B1: Single branch;
B2: Double branch
I0: No thermowell;
I1: No fixed device;
I2: Fixing thread;
I3: Movable flange;
I4: Fixed flange;
I5: Rectangular movable flange;
I6: Taper thermowell and fixing thread
C1: No protection head;
C2: All stainless steel protection head;
C3: Waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm;
D1: Φ25mm, double-deck;
D2: Φ16mm high quality aluminum;
D3: Φ20mm high quality aluminum

5. Thermocouple assembly installation diagram
Thermocouple assembly installation diagram

Application

Thermocouple  B type assembly application

Tips: Insulating bush of thermocouple
There must have favorable insulation between two pieces of thermode. And the insulating bush is just used to prevent short circuit of the two pieces of thermode. Various insulating materials have their own limitations, thus they must be selected according to temperature measurement and characteristics of insulating materials. For the convenience of usage, insulating materials are often made into round or oval shape tubular insulating bush, and structures include single-hole, double hole, four-hole and other specifications.

Fixed Installation Dimension Drawing

Design serial number1
Structure diagramThermocouple RDT sensor dimension
NameFixed thread
SizeM27*2 (default), G3/4", M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤10MPa
Design serial number2
Structure diagramThermocouple RDT sensor dimension
NameMovable flange
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltageAtmospheric pressure
Design serial number3
Structure diagramThermocouple RDT sensor dimension
NameFixed flange
SizeDN15mm (default)D095mmDN20mm105mm
D165mm75mm
D245mm55mm
φn4-φ14mm4-φ14mm
DN25mmD0115mmDN32mm140mm
D185mm100mm
D265mm78mm
φn4-φ14mm4-φ18mm
DN40mmD0150mmDN50mm165mm
D1110mm125mm
D285mm100mm
φn4-φ18mm4-φ18mm
H12mm
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤6.4MPa
Design serial number4
Structure diagramThermocouple RDT sensor dimension
NameConical fixed thread
SizeM27*2 (default), M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≥30MPa
Product reviews
Do you have programming software available for B type transmitters?
5
Carson
Avatar
5/26/2022 9:45 PM
We just purchased four of these smart B type transmitters, and I am scaling them for 4ma = 0° C (or 32° F) and 20ma = 1800° C (or 3272° F).  Is this correct?  It works out correct when I use a process meter to simulate the B thermocouple signal, but it is 300 degrees low @ 2250° F when connected to a real type B thermocouple.
Also, there is a programming port - do you have programming software available for that, or is it only factory programmed?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Carson,

Thanks for the feedback. This programming port is only used for factory programming calibration. Usually, the transmitter is calibrated when it leaves the factory. For  "it is 300 degrees low 2250° F when connected to a real type B thermocouple " you mentioned, could you please provide us with some pictures of the test for confirmation.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

As a temperature sensor, thermocouple assembly is usually used with display instruments, recording instruments and signal conditioners.

Specification

1. Thermocouple temperature range chart

CategoryType of sensing elementRelationship between wire diameter and temperature
Thermo wire diameter (mm)Long-term temperature (℃)Short-tem temperature (℃)
Platinum Rhodium 30 - Platinum Rhodium 6B typeΦ0.516001800
Platinum Rhodium 13 - PlatinumR typeΦ0.513001600
Platinum Rhodium 10 - PlatinumS typeΦ0.513001600
Nickel chromium silicon - Nickel silicon magnesiumN typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Nickel siliconK typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Copper nickelE typeΦ0.3350450
Φ0.5450550
Φ0.8, Φ1.0550650
Φ1.2, Φ1.6650750
Φ2.0, Φ2.5750900
Iron - ConstantanJ typeΦ0.3, Φ0.5300400
Φ0.8, Φ1.0400500
Φ1.2, Φ1.6500600
Φ2.0, Φ2.5600750
Copper - Copper nickelT typeΦ0.2150200
Φ0.3, Φ0.5200250
Φ1.0250300
Φ1.6350400

2. Thermowell application temperature range chart

Thermowell materialLong-term temperatureShort-term temperature
Corundum CT116001800
High alumina CT213001600
Nickel base wrought superalloys 3YC5213001350
Nickel base wrought superalloys GH303912501320
Nickel base superalloys GH303012001250
Heat resistant stainless steel 2Cr25Ni2012001250
Silicon carbide11001150
Stainless steel 316L900950
Stainless steel 1Cr18Ni9Ti800900

3. Thermowell installing form (unit: mm)
B type thermocouple installing form
4. Selection chart

Total length of thermowell (L or L*L1)Branch numberThermowell installing form
Protection head form
Diameter and material of thermowell
300~2150mm (for I1, I2, I3, I4);
500*500mm, 750*500mm, 750*750mm (for I5);
225~450mm (for I6)
B1: Single branch;
B2: Double branch
I0: No thermowell;
I1: No fixed device;
I2: Fixing thread;
I3: Movable flange;
I4: Fixed flange;
I5: Rectangular movable flange;
I6: Taper thermowell and fixing thread
C1: No protection head;
C2: All stainless steel protection head;
C3: Waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm;
D1: Φ25mm, double-deck;
D2: Φ16mm high quality aluminum;
D3: Φ20mm high quality aluminum

5. Thermocouple assembly installation diagram
Thermocouple assembly installation diagram

Application

Thermocouple  B type assembly application

Tips: Insulating bush of thermocouple
There must have favorable insulation between two pieces of thermode. And the insulating bush is just used to prevent short circuit of the two pieces of thermode. Various insulating materials have their own limitations, thus they must be selected according to temperature measurement and characteristics of insulating materials. For the convenience of usage, insulating materials are often made into round or oval shape tubular insulating bush, and structures include single-hole, double hole, four-hole and other specifications.

Product reviews
Do you have programming software available for B type transmitters?
5
Carson
Avatar
5/26/2022 9:45 PM
We just purchased four of these smart B type transmitters, and I am scaling them for 4ma = 0° C (or 32° F) and 20ma = 1800° C (or 3272° F).  Is this correct?  It works out correct when I use a process meter to simulate the B thermocouple signal, but it is 300 degrees low @ 2250° F when connected to a real type B thermocouple.
Also, there is a programming port - do you have programming software available for that, or is it only factory programmed?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Carson,

Thanks for the feedback. This programming port is only used for factory programming calibration. Usually, the transmitter is calibrated when it leaves the factory. For  "it is 300 degrees low 2250° F when connected to a real type B thermocouple " you mentioned, could you please provide us with some pictures of the test for confirmation.
Only registered users can write reviews