Thermocouple, T type, Assembly

$53.85
T type thermocouple assembles with protection head and stainless steel thermowell, with high pressure resistant, fast thermal response time and long operating life. Its thermo wire diameter is Ф2.5mm. T type thermocouple has the highest accuracy and lowest price in base metals, can directly measure the temperature of liquid, vapor, gas medium and solid surface in the range of -40~300 ℃ in various production processes.
SKU: ATO-TC-TA
*
This product has a minimum quantity of 2
Free Shipping
Delivery date: 6-12 days

As a temperature sensor, thermocouple assembly is usually used with display instruments, recording instruments and signal conditioners.

Specification

1. Thermocouple temperature range chart

CategoryType of sensing elementRelationship between wire diameter and temperature
Thermo wire diameter (mm)Long-term temperature (℃)Short-tem temperature (℃)
Platinum Rhodium 30 - Platinum Rhodium 6B typeΦ0.516001800
Platinum Rhodium 13 - PlatinumR typeΦ0.513001600
Platinum Rhodium 10 - PlatinumS typeΦ0.513001600
Nickel chromium silicon - Nickel silicon magnesiumN typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Nickel siliconK typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Copper nickelE typeΦ0.3350450
Φ0.5450550
Φ0.8, Φ1.0550650
Φ1.2, Φ1.6650750
Φ2.0, Φ2.5750900
Iron - ConstantanJ typeΦ0.3, Φ0.5300400
Φ0.8, Φ1.0400500
Φ1.2, Φ1.6500600
Φ2.0, Φ2.5600750
Copper - Copper nickelT typeΦ0.2150200
Φ0.3, Φ0.5200250
Φ1.0250300
Φ1.6350400

2. Thermowell application temperature range chart

Thermowell materialLong-term temperatureShort-term temperature
Corundum CT116001800
High alumina CT213001600
Nickel base wrought superalloys 3YC5213001350
Nickel base wrought superalloys GH303912501320
Nickel base superalloys GH303012001250
Heat resistant stainless steel 2Cr25Ni2012001250
Silicon carbide11001150
Stainless steel 316L900950
Stainless steel 1Cr18Ni9Ti800900

3. Thermowell installing form (unit: mm)
Thermocouple thermowell installing form
4. Selection chart

Total length of thermowell (L or L*L1)Branch numberThermowell installing formProtection head formDiameter and material of thermowell
300~2150mm (for I1, I2, I3, I4);
500*500mm, 750*500mm, 750*750mm (for I5);
225~450mm (for I6)
B1: Single branch;
B2: Double branch
I0: No thermowell;
I1: No fixed device;
I2: Fixing thread;
I3: Movable flange;
I4: Fixed flange;
I5: Rectangular movable flange;
I6: Taper thermowell and fixing thread
C1: No protection head;
C2: All stainless steel protection head;
C3: Waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm;
D1: Φ25mm, double-deck;
D2: Φ16mm high quality aluminum;
D3: Φ20mm high quality aluminum

5. Thermocouple assembly installation diagram
Thermocouple assembly installation diagram

Application

Thermocouple T type assembly application

Tips: Troubleshooting for thermocouple terminal
According to temperature measurement principles of thermocouple, we can know that thermal electromotive force includes two parts, contact potential and temperature difference potential. If contact between field terminal and extension wire of thermocouple, and extension wire and secondary instrument of the control room is not favorable, there will be additional contact potential in the signal transmitting process of thermocouple, and thus causing errors of temperature measurement. If wiring connection is not favorable, there will be sharp jump of temperature measurement. At this time, field reconnection will eliminate the fault of extension wire.
If there are connectors in the middle of extension wire, the influence of contact potential on temperature measurement will come, thus it will be better if there are no plugs in the usage of extension wire. If plugs cannot be avoided, it is necessary to mark position of connectors besides connecting treatment. Once there is temperature measurement fault, find out the position of connectors of extension wire; otherwise, faults caused by extension wire are hard to be eliminated.

Fixed Installation Dimension Drawing

Design serial number1
Structure diagramThermocouple RDT sensor dimension
NameFixed thread
SizeM27*2 (default), G3/4", M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤10MPa
Design serial number2
Structure diagramThermocouple RDT sensor dimension
NameMovable flange
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltageAtmospheric pressure
Design serial number3
Structure diagramThermocouple RDT sensor dimension
NameFixed flange
SizeDN15mm (default)D095mmDN20mm105mm
D165mm75mm
D245mm55mm
φn4-φ14mm4-φ14mm
DN25mmD0115mmDN32mm140mm
D185mm100mm
D265mm78mm
φn4-φ14mm4-φ18mm
DN40mmD0150mmDN50mm165mm
D1110mm125mm
D285mm100mm
φn4-φ18mm4-φ18mm
H12mm
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≤6.4MPa
Design serial number4
Structure diagramThermocouple RDT sensor dimension
NameConical fixed thread
SizeM27*2 (default), M33*2, G1", other
Protection tubeDiameterφ12mm, φ16mm, other
Texture of material1Cr18Ni9Ti, 2Cr25Ni20, other
Withstand voltage≥30MPa
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

As a temperature sensor, thermocouple assembly is usually used with display instruments, recording instruments and signal conditioners.

Specification

1. Thermocouple temperature range chart

CategoryType of sensing elementRelationship between wire diameter and temperature
Thermo wire diameter (mm)Long-term temperature (℃)Short-tem temperature (℃)
Platinum Rhodium 30 - Platinum Rhodium 6B typeΦ0.516001800
Platinum Rhodium 13 - PlatinumR typeΦ0.513001600
Platinum Rhodium 10 - PlatinumS typeΦ0.513001600
Nickel chromium silicon - Nickel silicon magnesiumN typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Nickel siliconK typeΦ0.3700800
Φ0.5800900
Φ0.8, Φ1.09001000
Φ1.2, Φ1.610001100
Φ2.0, Φ2.511001200
Φ3.212001300
Nickel chromium - Copper nickelE typeΦ0.3350450
Φ0.5450550
Φ0.8, Φ1.0550650
Φ1.2, Φ1.6650750
Φ2.0, Φ2.5750900
Iron - ConstantanJ typeΦ0.3, Φ0.5300400
Φ0.8, Φ1.0400500
Φ1.2, Φ1.6500600
Φ2.0, Φ2.5600750
Copper - Copper nickelT typeΦ0.2150200
Φ0.3, Φ0.5200250
Φ1.0250300
Φ1.6350400

2. Thermowell application temperature range chart

Thermowell materialLong-term temperatureShort-term temperature
Corundum CT116001800
High alumina CT213001600
Nickel base wrought superalloys 3YC5213001350
Nickel base wrought superalloys GH303912501320
Nickel base superalloys GH303012001250
Heat resistant stainless steel 2Cr25Ni2012001250
Silicon carbide11001150
Stainless steel 316L900950
Stainless steel 1Cr18Ni9Ti800900

3. Thermowell installing form (unit: mm)
Thermocouple thermowell installing form
4. Selection chart

Total length of thermowell (L or L*L1)Branch numberThermowell installing formProtection head formDiameter and material of thermowell
300~2150mm (for I1, I2, I3, I4);
500*500mm, 750*500mm, 750*750mm (for I5);
225~450mm (for I6)
B1: Single branch;
B2: Double branch
I0: No thermowell;
I1: No fixed device;
I2: Fixing thread;
I3: Movable flange;
I4: Fixed flange;
I5: Rectangular movable flange;
I6: Taper thermowell and fixing thread
C1: No protection head;
C2: All stainless steel protection head;
C3: Waterproof protection head;
C4: Explosion-proof protection head
D0: Φ16mm;
D1: Φ25mm, double-deck;
D2: Φ16mm high quality aluminum;
D3: Φ20mm high quality aluminum

5. Thermocouple assembly installation diagram
Thermocouple assembly installation diagram

Application

Thermocouple T type assembly application

Tips: Troubleshooting for thermocouple terminal
According to temperature measurement principles of thermocouple, we can know that thermal electromotive force includes two parts, contact potential and temperature difference potential. If contact between field terminal and extension wire of thermocouple, and extension wire and secondary instrument of the control room is not favorable, there will be additional contact potential in the signal transmitting process of thermocouple, and thus causing errors of temperature measurement. If wiring connection is not favorable, there will be sharp jump of temperature measurement. At this time, field reconnection will eliminate the fault of extension wire.
If there are connectors in the middle of extension wire, the influence of contact potential on temperature measurement will come, thus it will be better if there are no plugs in the usage of extension wire. If plugs cannot be avoided, it is necessary to mark position of connectors besides connecting treatment. Once there is temperature measurement fault, find out the position of connectors of extension wire; otherwise, faults caused by extension wire are hard to be eliminated.

Only registered users can write reviews