Portable Chlorine Dioxide (ClO2) Gas Detector, 0 to 10/20/50/100 ppm

$802.22
Handheld Chlorine Dioxide (ClO2) gas detector for sale online. Safety portable gas monitor equipped with 0 to 1/10/20/50/100 ppm measuring range, high-precision sensors, alarms and LCD display, can accurately monitor Chlorine Dioxide gas concentrations, convenient to carry and read test results.
SKU: GD200-ClO2
*
*
*
Free Shipping
Delivery date: 6-12 days

Factory price Chlorine Dioxide gas detector can be used for monitoring ClO2 gas. With a high-precision sensor, 0 to 1/10/20/50/100 ppm measuring range, clear LCD display, and compact handheld design, this portable single gas detector is suitable for water treatment, bleaching, and other industrial processes.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-ClO2
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasChlorine Dioxide (ClO2)
Range (Optional)*0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm
Resolution0.001ppm (0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube

Note 1:

  • If you require an ClO2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Handheld Ammonia (NH3) Gas Detector Details

Applications

HF gas detector applications

Tips: What is a portable Chlorine Dioxide (ClO2) gas detector?

ATO portable Chlorine Dioxide (ClO2) gas detector is a crucial safety device designed to monitor and alert users to the presence of ClO2 gas in various environments. Chlorine Dioxide is a potent disinfectant used in water treatment, bleaching, and other industrial processes, but it is also highly toxic and can pose significant health risks if inhaled.

These portable detectors are compact, lightweight, and easy to carry, making them ideal for use in confined spaces, industrial sites, and fieldwork. They typically feature a digital display that shows real-time ClO2 concentrations, audible and visual alarms to alert users when gas levels exceed safe limits, and data logging capabilities for record-keeping and compliance purposes.

Key features often include high sensitivity and specificity to ClO2, fast response times, and durable construction to withstand harsh conditions. Many models are equipped with rechargeable batteries, user-friendly interfaces, and calibration functions to ensure accurate readings. By providing continuous monitoring, these devices help protect workers from potential exposure, ensuring a safer working environment and compliance with occupational safety regulations.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Product reviews
Pool Gas Detection
5
Enlis
Avatar
10/10/2025 8:05 PM
Pools use chlorine and acid, and I'm not sure what type of acid it is. We know that mixing these two chemicals can produce toxic gases, so we just want to make sure we have an early warning if that happens.
Was this review helpful? Yes No (0/0)
ATO Responded
Please tell us what the acid is so we can recommend an appropriate detector. Do you want to detect toxic gases escaping from your pool?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Factory price Chlorine Dioxide gas detector can be used for monitoring ClO2 gas. With a high-precision sensor, 0 to 1/10/20/50/100 ppm measuring range, clear LCD display, and compact handheld design, this portable single gas detector is suitable for water treatment, bleaching, and other industrial processes.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-ClO2
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasChlorine Dioxide (ClO2)
Range (Optional)*0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm
Resolution0.001ppm (0-1/5ppm), 0.01ppm (0-10/20/50ppm), 0.1ppm (0-100ppm)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation) ; Outlet: Ф6 flexible tube

Note 1:

  • If you require an ClO2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Handheld Ammonia (NH3) Gas Detector Details

Applications

HF gas detector applications

Tips: What is a portable Chlorine Dioxide (ClO2) gas detector?

ATO portable Chlorine Dioxide (ClO2) gas detector is a crucial safety device designed to monitor and alert users to the presence of ClO2 gas in various environments. Chlorine Dioxide is a potent disinfectant used in water treatment, bleaching, and other industrial processes, but it is also highly toxic and can pose significant health risks if inhaled.

These portable detectors are compact, lightweight, and easy to carry, making them ideal for use in confined spaces, industrial sites, and fieldwork. They typically feature a digital display that shows real-time ClO2 concentrations, audible and visual alarms to alert users when gas levels exceed safe limits, and data logging capabilities for record-keeping and compliance purposes.

Key features often include high sensitivity and specificity to ClO2, fast response times, and durable construction to withstand harsh conditions. Many models are equipped with rechargeable batteries, user-friendly interfaces, and calibration functions to ensure accurate readings. By providing continuous monitoring, these devices help protect workers from potential exposure, ensuring a safer working environment and compliance with occupational safety regulations.

Product reviews
Pool Gas Detection
5
Enlis
Avatar
10/10/2025 8:05 PM
Pools use chlorine and acid, and I'm not sure what type of acid it is. We know that mixing these two chemicals can produce toxic gases, so we just want to make sure we have an early warning if that happens.
Was this review helpful? Yes No (0/0)
ATO Responded
Please tell us what the acid is so we can recommend an appropriate detector. Do you want to detect toxic gases escaping from your pool?
Only registered users can write reviews