Pneumatic Solenoid Valve, 3 Way, Normally Closed, 12V/24V/110V/220V

$48.59
$54.77
3/2 way - 3 port 2 position Normally Closed (N/C) pneumatic solenoid valve is suitable for the air control. It is internally piloted type, with optional port size M5×0.8, Rc 1/8", Rc 1/4", Rc 3/8", Rc 1/2" and operating voltage DC 12 volt, DC 24 volt, AC110 volt, AC 220 volt. High quality, long life and low price.
SKU: ATO-VALVE-3VNC
*
*
Free Shipping
Delivery date: 6-12 days

Note: This solenoid valve cannot be used for drinking water.

Pneumatic solenoid valve, 2-position 3-port, normally closed, single solenoid, is used to handle the flow of air with long service life and high reliability under the working voltage of 12V DC, 24V DC, 110V AC or 220V AC, and widely used in the industrial fields like chemical, petroleum, pharmaceutical, automotive, light industry, food, mineral processing, electroplating, metallurgy, textiles etc.

Specification

ModelATO-3V110-M5-NCATO-3V110-06-NCATO-3V210-06-NCATO-3V210-08-NCATO-3V310-08-NCATO-3V310-10-NCATO-3V410-15-NC
Number of Ports3-way (3-port)
Number of Positions2-position
Valve TypeNormally Closed
Operation ModeInternally piloted
Number of SolenoidSingle
Port SizeM5×0.8Rc 1/8"Rc 1/8"Rc 1/4"Rc 1/4"Rc 3/8"Rc 1/2"
MediaAir
Operating Pressure Range0.15~0.8MPa (22~116PSI)
Max. Pressure Resistance1.2MPa
Voltage (Optional)12V DC, 24V DC, 110V AC, 220V AC
DimensionSee below table
Voltage Tolerance-10%~+10%
Operating Temperature5℃~60℃ (41℉~140℉)
Insulation GradeClass B
Protection GradeIP65
Body MaterialAluminum Alloy
Seal MaterialNBR
Wiring MethodTerminal type
Max. Action Frequency5Hz (5 cycles/second)
LubricationNo

Dimensions
(body length unit = mm, port size unit = inch)
3/2-Way N/C Pneumatic Solenoid Valve Dimensions

ModelABCDEFGHIJKLMNOPQRST
3V110-M5-NC131822.70M5×0.819Φ3.313.2Φ3.1272.588.45512.2217.70M5×0.814.214.7
3V110-06-NC131823.71PT1/819Φ3.313.2Φ3.1272.588.45512.2217.72PT1/81614.7
3V210-06-NC172227.70PT1/830Φ3.212.7Φ4.235310966.715.2258.20PT1/82216.7
3V210-08-NC172228.71.5PT1/430Φ3.212.7Φ4.235310966.715.2258.20PT1/422.516.7
3V310-08-NC202732.50PT1/435Φ4.315Φ4.3402.412069.217.53010.50PT1/42420.5
3V310-10-NC202732.52PT3/835Φ4.315Φ4.3402.412069.217.53010.50PT3/82420.5
3V410-15-NC2734423PT1/248Φ4.517.5Φ4.5502.81387417.548130PT1/23525

Solenoid Valve Symbol (Flow Diagram)

3-Way 2-Position Solenoid Valve NC SymbolTips: Differences between pilot-operated and direct acting solenoid valve

1. Pressure tolerance
The pilot-operated solenoid valve has a higher tolerance of liquid pressure than the direct acting solenoid valve.

2. Response time
The starting speed of the direct acting solenoid valve is quicker than that of the directly operated type. It is mostly used for the occasion of fast connection and disconnection. Because the small valve opens in the first and the main valve opens later when the pilot-operated solenoid valve is supplied with power. Instead, the directly operated solenoid valve is opened with its main valve directly. When the pilot-operated solenoid valve is energized, the small valve opens at the first and the main valve opens later. However, as to the direct acting solenoid valve, the main solenoid opens directly.

3. Flow capacity
The flow capacity of the pilot-operated solenoid valve is bigger than that of the directly operated type. Generally, the CV value can reach 3 or above.

4. Power and consumption
The power and consumption of the directly operated solenoid valve are higher than that of the pilot-operated type.

5. Purity of the medium
The pilot-operated solenoid valve has a relatively high requirement to the purity of the flowing medium. However, the direct acting type has no such strict requirement.

DC12V/24V Pneumatic Solenoid Valve

In this video, the characteristics, working principle and application scope of DC12V/24V pneumatic solenoid valve are introduced in detail.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Can this item be used for vacuum?
5
Daniel
Avatar
11/14/2018 5:54 PM
Can this item be used for vacuum?
Was this review helpful? Yes No (0/0)
ATO Responded
No, this pneumatic solenoid valve is not suitable for vacuum environment. It should be used under the conditions as the specs described.
The valve worked great.
5
Milan
Avatar
4/15/2019 9:18 PM
I bought this to replace the broken one for the air locker. The valve worked great…thank you.
Was this review helpful? Yes No (0/0)
Pressure range of pneumatic solenoid valve
5
Blaire
Avatar
10/24/2021 9:12 PM
For your pneumatic solenoid alve, what is the nominal pressure range it can work at and can it work in vacuum systems?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Nominal pressure range: 0.15~0.8MPa (22~116 psi).
2. There is no solenoid valve that works in vacuum.
Buy an Electric Valve
4
Renault
Avatar
4/27/2026 3:03 AM
I need an electric valve for a carbon dioxide gas line. Its inner diameter is 8 mm and its outer diameter is 12 mm. The gas flow rate should be within the range of 60 liters/minute. I want to be able to control the opening and closing of the gas flow via a switch. The valve needs to be powered by a 5 to 24 VDC DC power supply. Do you have any recommended products?
Was this review helpful? Yes No (0/0)
ATO Responded
The specifications you are currently viewing are for standard solenoid valves. We suggest you browse our product list on our website to confirm whether we have the specific model you need: https://www.ato.com/pneumatic-solenoid-valves
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Note: This solenoid valve cannot be used for drinking water.

Pneumatic solenoid valve, 2-position 3-port, normally closed, single solenoid, is used to handle the flow of air with long service life and high reliability under the working voltage of 12V DC, 24V DC, 110V AC or 220V AC, and widely used in the industrial fields like chemical, petroleum, pharmaceutical, automotive, light industry, food, mineral processing, electroplating, metallurgy, textiles etc.

Specification

ModelATO-3V110-M5-NCATO-3V110-06-NCATO-3V210-06-NCATO-3V210-08-NCATO-3V310-08-NCATO-3V310-10-NCATO-3V410-15-NC
Number of Ports3-way (3-port)
Number of Positions2-position
Valve TypeNormally Closed
Operation ModeInternally piloted
Number of SolenoidSingle
Port SizeM5×0.8Rc 1/8"Rc 1/8"Rc 1/4"Rc 1/4"Rc 3/8"Rc 1/2"
MediaAir
Operating Pressure Range0.15~0.8MPa (22~116PSI)
Max. Pressure Resistance1.2MPa
Voltage (Optional)12V DC, 24V DC, 110V AC, 220V AC
DimensionSee below table
Voltage Tolerance-10%~+10%
Operating Temperature5℃~60℃ (41℉~140℉)
Insulation GradeClass B
Protection GradeIP65
Body MaterialAluminum Alloy
Seal MaterialNBR
Wiring MethodTerminal type
Max. Action Frequency5Hz (5 cycles/second)
LubricationNo

Dimensions
(body length unit = mm, port size unit = inch)
3/2-Way N/C Pneumatic Solenoid Valve Dimensions

ModelABCDEFGHIJKLMNOPQRST
3V110-M5-NC131822.70M5×0.819Φ3.313.2Φ3.1272.588.45512.2217.70M5×0.814.214.7
3V110-06-NC131823.71PT1/819Φ3.313.2Φ3.1272.588.45512.2217.72PT1/81614.7
3V210-06-NC172227.70PT1/830Φ3.212.7Φ4.235310966.715.2258.20PT1/82216.7
3V210-08-NC172228.71.5PT1/430Φ3.212.7Φ4.235310966.715.2258.20PT1/422.516.7
3V310-08-NC202732.50PT1/435Φ4.315Φ4.3402.412069.217.53010.50PT1/42420.5
3V310-10-NC202732.52PT3/835Φ4.315Φ4.3402.412069.217.53010.50PT3/82420.5
3V410-15-NC2734423PT1/248Φ4.517.5Φ4.5502.81387417.548130PT1/23525

Solenoid Valve Symbol (Flow Diagram)

3-Way 2-Position Solenoid Valve NC SymbolTips: Differences between pilot-operated and direct acting solenoid valve

1. Pressure tolerance
The pilot-operated solenoid valve has a higher tolerance of liquid pressure than the direct acting solenoid valve.

2. Response time
The starting speed of the direct acting solenoid valve is quicker than that of the directly operated type. It is mostly used for the occasion of fast connection and disconnection. Because the small valve opens in the first and the main valve opens later when the pilot-operated solenoid valve is supplied with power. Instead, the directly operated solenoid valve is opened with its main valve directly. When the pilot-operated solenoid valve is energized, the small valve opens at the first and the main valve opens later. However, as to the direct acting solenoid valve, the main solenoid opens directly.

3. Flow capacity
The flow capacity of the pilot-operated solenoid valve is bigger than that of the directly operated type. Generally, the CV value can reach 3 or above.

4. Power and consumption
The power and consumption of the directly operated solenoid valve are higher than that of the pilot-operated type.

5. Purity of the medium
The pilot-operated solenoid valve has a relatively high requirement to the purity of the flowing medium. However, the direct acting type has no such strict requirement.

Product reviews
Can this item be used for vacuum?
5
Daniel
Avatar
11/14/2018 5:54 PM
Can this item be used for vacuum?
Was this review helpful? Yes No (0/0)
ATO Responded
No, this pneumatic solenoid valve is not suitable for vacuum environment. It should be used under the conditions as the specs described.
The valve worked great.
5
Milan
Avatar
4/15/2019 9:18 PM
I bought this to replace the broken one for the air locker. The valve worked great…thank you.
Was this review helpful? Yes No (0/0)
Pressure range of pneumatic solenoid valve
5
Blaire
Avatar
10/24/2021 9:12 PM
For your pneumatic solenoid alve, what is the nominal pressure range it can work at and can it work in vacuum systems?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Nominal pressure range: 0.15~0.8MPa (22~116 psi).
2. There is no solenoid valve that works in vacuum.
Buy an Electric Valve
4
Renault
Avatar
4/27/2026 3:03 AM
I need an electric valve for a carbon dioxide gas line. Its inner diameter is 8 mm and its outer diameter is 12 mm. The gas flow rate should be within the range of 60 liters/minute. I want to be able to control the opening and closing of the gas flow via a switch. The valve needs to be powered by a 5 to 24 VDC DC power supply. Do you have any recommended products?
Was this review helpful? Yes No (0/0)
ATO Responded
The specifications you are currently viewing are for standard solenoid valves. We suggest you browse our product list on our website to confirm whether we have the specific model you need: https://www.ato.com/pneumatic-solenoid-valves
Only registered users can write reviews
Customers who bought this item also bought

Pneumatic Solenoid Valve, 3 Way, Normally Open, 12V/24V/110V/220V

ATO-VALVE-3VNO
$48.59 $54.77
Three-way Two-position (3/2-way) pneumatic solenoid valve, Normally Open (N/O), single coil, can handle the flow of air in safe and fast. The supply voltage is selectable among DC 12V, DC 24V, AC 110Vand AC 220V, and the port size is also avaliable with M5×0.8, Rc 1/8", Rc 1/4", Rc 3/8", Rc 1/2" for your choice.