Note: This solenoid valve cannot be used for drinking water.
Genral purpose Two-way two-position Normally Open (NO) brass electric solenoid valves are used to release and shut off the flow of air, water and oil with power supply of 24V DC or 110V AC, 220V AC. The solenoid valve is closed when the solenoid is energized; the valve is open when the solenoid is de-energized. It is widely used in the areas like mechanical, textile, medical, food processing and so on.
Specification
| Model | 2WK160-15 | 2WK200-20 | 2WK250-25 | 2WK350-35 | 2WK400-40 | 2WK500-50 | |
| Valve Type | 2 Way 2 Position, Normally Open | ||||||
| Media | Water, Oil, Air | ||||||
| Operation Mode | Pilot-operated | ||||||
| Port Diameter (mm) | 16 | 20 | 25 | 35 | 40 | 50 | |
| Flow Rate (Cv) | 4.8 | 7.6 | 12 | 24 | 29 | 48 | |
| Port Size | G1/2" | G3/4" | G1" | G1¼" | G1½" | G2" | |
| Fluid Viscosity | Under 20 CS | ||||||
| Operating Pressure | Water, Oil: 0~0.5MPa (0~72psi) Air: 0~0.7MPa (0~101psi) | ||||||
| Max. Pressure Resistance | 1.0MPa | ||||||
| Voltage (Optional) | 24V DC, 110V AC, 220V AC | ||||||
| Voltage Tolerance | ±10% | ||||||
| Operating Temperature | -5~+85℃ (23~185℉) | ||||||
| Body Material | Brass | ||||||
| Seal Material | NBR | ||||||
| Coil Power | 20VA | ||||||
Dimensions
| Model | Dimension | |||
| Port size (inch) | A (mm) | B (mm) | C (mm) | |
| 2WK160-15 | G1/2" | 67.5 | 55.5 | 124.5 |
| 2WK200-20 | G3/4" | 73 | 55.5 | 130 |
| 2WK250-25 | G1" | 94 | 72.5 | 136.5 |
| 2WK350-35 | G1¼" | 120 | 92.5 | 151.5 |
| 2WK400-40 | G1½" | 122 | 92.5 | 157.5 |
| 2WK500-50 | G2" | 129 | 95 | 170 |
Two-way Solenoid Valve Symbol
5 Tips for Solenoid Valve Maintenance
- Regular inspection and maintenance, once or twice a year, is the best way to ensure the solenoid valve reliable work and long service life.
- When the solenoid valve is put into operation after the installation or after a long time stop, it needs to inject the medium for several times for test runs. The solenoid valve cannot be placed into service until it works normally.
- Before the maintenance, the power supply of solenoid valve must be cut off and the pressure of the medium should be discharged.
- The coil components should not be disassembled.
- All parts of the solenoid valve should be put in order when the valve is disassembled for cleaning. Thus, it is able to assemble the parts in order after cleaning.
Product reviews
Great Item, Good Service
Rubem
3/20/2019 2:06 AM
Last month, I bought the 24V DC version of this 2 way solenoid valve for preventing fresh water from overflowing bowl. It works really perfectly as so far. As summer is coming, I am considering using one of other version to water my small garden.
Was this review helpful? (0/0)
What is the rated power of the 2 way solenoid valve?
Atalla
11/4/2021 11:55 PM
What is the power rating for your ATO 2 way valve 24VDC?
Was this review helpful? (0/0)
Do you provide the solenoid valve we need?
Garyca
11/26/2021 12:57 AM
We need Galvanized carbon steel and nylon solenoid valves. Do you provide it?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
Solenoid Valve, 2 Way, Normally Closed, 12V/24V/220V for air water oil
ATO-VALVE-2W
$50.75 $62.92
Low price 2/2-way normally closed solenoid valve, 2-way 2-position (N/C), has different port sizes 1/4", 3/8", 1/2", 3/4" to 2", and operating voltages DC 12V, DC 24V, AC 110V or AC 220V for options. Valve body is made of brass and sealing material is NBR, general-purpose solenoid valve for control the flow of air, water and oil with good medium compatibility, high reliability and long service life.