Oval Gear Flow Sensor, Hall Effect, DN8/DN10/DN15

$121.23
Oval gear flow sensor with hall effect is a high-precision industrial flow meter for oil, fuel, and viscous liquid measurement. Available in Nominal Diameters DN8, DN10, and DN15, made of stainless steel, it ensures accurate digital flow monitoring, strong wear resistance, and stable long-term performance.
SKU: ATO-FS-OFZAT02
*
Free Shipping
Delivery date: 6-12 days

High-precision oval gear flow sensor, ideal for measuring high-viscosity or high-concentration liquids like oil, features Hall effect technology for accurate flow monitoring and reliable process control, with available configurations in nominal diameters DN8, DN10, and DN15 to meet industrial application needs.

Specification

Product ModelATO-ZJ-HSM-OFZATS-02ATO-ZJ-HSM-OFZATS-03ATO-ZJ-HSM-OFZATL-04
Connection SizeG1/4'' (2mm)G3/8'' (3mm)G1/2'' (4mm)
Nominal DiameterDN8DN10DN15
Voltage Range3.5-24VDC
Water Pressure Resistance≤1.0MPa
Suitable MediaOil/Honey/Milk and other high-concentration liquids
MaterialStainless Steel
Media Temperature0~80℃
Insulation Resistance>100MΩ
Flow Rate Range30-300L/H40-800L/H30-1200L/H
Pulse RangeF=(1.9×Q)with error≤1%, i.e., 114 pulses per liter of waterF=(2.3×Q)with error≤1%, i.e., 138 pulses per liter of waterF=(2.3×Q)with error≤ 1%, i.e., 138 pulses per liter of water
Output pulse high level>DC 4.7V (input voltage DC 5V)
Output pulse low level<DC 0.5V (input voltage DC 5V)


Feature

  1. High Accuracy: Oval gear flow sensor with ±1% precision ensures stable and reliable oil and fuel flow measurement in industrial systems.
  2. Durable Construction: Industrial flow meter made of stainless steel, corrosion-resistant and wear-resistant for long-term use in harsh environments.
  3. Hall Effect Technology: Gear flow sensor with Hall effect output delivers fast and accurate pulse signals for precise flow monitoring and process control.
  4. Wide Application: Ideal for industrial automation, fuel monitoring, and viscous liquid measurement in petrochemical and mechanical equipment.

Dimension

DN8: G1/4'' (2mm)

Oval gear flow sensor dimension OFZAT-02

DN10: G3/8'' (3mm)

Oval gear flow sensor dimension OFZAT-03

DN15: G1/2'' (4mm)

Oval gear flow sensor dimension ZJ-HSM-OFZATL-04

Output Waveform Diagram

Oval gear low sensor output waveform diagram

Wiring Method

oval gear flow sensor wiring method

Application

Perfect for cruise ships, petrochemical plants, fuel dispensers, and industrial machines, this sensor delivers accurate and reliable flow measurement for oils, fuels, and other viscous liquids.

Gear flow sensor application

Tips: How to get the most accurate readings from your oval gear flow sensor?

To achieve optimal accuracy, install the flow sensor horizontally and follow the arrow indicating the correct flow direction. Before installation, flush the pipeline to remove any impurities that could block the gears or affect the Hall signal. Keep the liquid flow stable within the rated range—especially for high-viscosity media like oil or honey—to ensure consistent pulse output. Connect the Hall effect signal to PLCs or digital monitors for real-time, precise flow tracking. For long-term reliability, perform regular calibration and gently clean the sensor chamber to preserve its ±1% accuracy.

Product reviews
Accurate and easy to use
5
Benjamin
Avatar
11/19/2025 1:22 AM
I used it for measuring oil, and the readings are stable and accurate. The aluminum body feels solid, installation was simple, and the pulse signal is clean for connecting to my equipment. Overall, it works well.
Was this review helpful? Yes No (0/0)
Flow sensor with threaded connection
5
Hillbers
Avatar
2/6/2026 1:02 AM
I need a flow sensor with a threaded connection. Which models best match the specifications I provided?
Was this review helpful? Yes No (0/0)
ATO Responded
This oval gear Hall effect flow sensor, product number: ATO-FS-OFZAT02, has an operating pressure ≤1 MPa, which does not reach 210 bar. Could you please take a look and see if it's suitable?
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High-precision oval gear flow sensor, ideal for measuring high-viscosity or high-concentration liquids like oil, features Hall effect technology for accurate flow monitoring and reliable process control, with available configurations in nominal diameters DN8, DN10, and DN15 to meet industrial application needs.

Specification

Product ModelATO-ZJ-HSM-OFZATS-02ATO-ZJ-HSM-OFZATS-03ATO-ZJ-HSM-OFZATL-04
Connection SizeG1/4'' (2mm)G3/8'' (3mm)G1/2'' (4mm)
Nominal DiameterDN8DN10DN15
Voltage Range3.5-24VDC
Water Pressure Resistance≤1.0MPa
Suitable MediaOil/Honey/Milk and other high-concentration liquids
MaterialStainless Steel
Media Temperature0~80℃
Insulation Resistance>100MΩ
Flow Rate Range30-300L/H40-800L/H30-1200L/H
Pulse RangeF=(1.9×Q)with error≤1%, i.e., 114 pulses per liter of waterF=(2.3×Q)with error≤1%, i.e., 138 pulses per liter of waterF=(2.3×Q)with error≤ 1%, i.e., 138 pulses per liter of water
Output pulse high level>DC 4.7V (input voltage DC 5V)
Output pulse low level<DC 0.5V (input voltage DC 5V)


Feature

  1. High Accuracy: Oval gear flow sensor with ±1% precision ensures stable and reliable oil and fuel flow measurement in industrial systems.
  2. Durable Construction: Industrial flow meter made of stainless steel, corrosion-resistant and wear-resistant for long-term use in harsh environments.
  3. Hall Effect Technology: Gear flow sensor with Hall effect output delivers fast and accurate pulse signals for precise flow monitoring and process control.
  4. Wide Application: Ideal for industrial automation, fuel monitoring, and viscous liquid measurement in petrochemical and mechanical equipment.

Dimension

DN8: G1/4'' (2mm)

Oval gear flow sensor dimension OFZAT-02

DN10: G3/8'' (3mm)

Oval gear flow sensor dimension OFZAT-03

DN15: G1/2'' (4mm)

Oval gear flow sensor dimension ZJ-HSM-OFZATL-04

Output Waveform Diagram

Oval gear low sensor output waveform diagram

Wiring Method

oval gear flow sensor wiring method

Application

Perfect for cruise ships, petrochemical plants, fuel dispensers, and industrial machines, this sensor delivers accurate and reliable flow measurement for oils, fuels, and other viscous liquids.

Gear flow sensor application

Tips: How to get the most accurate readings from your oval gear flow sensor?

To achieve optimal accuracy, install the flow sensor horizontally and follow the arrow indicating the correct flow direction. Before installation, flush the pipeline to remove any impurities that could block the gears or affect the Hall signal. Keep the liquid flow stable within the rated range—especially for high-viscosity media like oil or honey—to ensure consistent pulse output. Connect the Hall effect signal to PLCs or digital monitors for real-time, precise flow tracking. For long-term reliability, perform regular calibration and gently clean the sensor chamber to preserve its ±1% accuracy.

Product reviews
Accurate and easy to use
5
Benjamin
Avatar
11/19/2025 1:22 AM
I used it for measuring oil, and the readings are stable and accurate. The aluminum body feels solid, installation was simple, and the pulse signal is clean for connecting to my equipment. Overall, it works well.
Was this review helpful? Yes No (0/0)
Flow sensor with threaded connection
5
Hillbers
Avatar
2/6/2026 1:02 AM
I need a flow sensor with a threaded connection. Which models best match the specifications I provided?
Was this review helpful? Yes No (0/0)
ATO Responded
This oval gear Hall effect flow sensor, product number: ATO-FS-OFZAT02, has an operating pressure ≤1 MPa, which does not reach 210 bar. Could you please take a look and see if it's suitable?
Only registered users can write reviews