Brass Oval Gear Flow Sensor, DN20, 30-3000L/h

$95.88
Gear flow sensor with a nominal diameter of DN20 features a durable brass valve body and an imported hall sensor. Provides high accuracy, stable performance, and long service life for industrial flow monitoring.
SKU: ATO-FS-OFZAT06T
Free Shipping
Delivery date: 6-12 days

DN20 brass oval gear flow sensor provides accurate flow measurement from 30–3000 L/h with ±5% precision. Built with a durable brass body and equipped with a reliable Hall effect sensor, it ensures stable pulse output and long-term durability. With low power consumption, wide temperature tolerance, and strong pressure resistance, this industrial flow sensor is widely used in petrochemical plants, refineries, tankers, and other flow control applications.

Specifications

ModelATO-OFZAT-06T
MaterialCopper valve body
Nominal DiameterDN20
Inner Diameter/Outer Diameter24.5mm/27.8mm
Accuracy Class±5%
Working Pressure≤1.2 bar
Working Temperature0-120°C
Working Voltage Range5-24VDC
Maximum Operating Current15mA (DC5V)
Load Capacity≤10mA (DC5V)
Allowable Withstand Pressure≤1.0MPa
Storage Temperature/Humidity-25~+80℃/25%~90%RH
Flow Range30-3000L/H±2%
Pulse Characteristics(Hz) = [1.2*Q] ±5%, i.e., 72 pulses per liter of water
Output Pulse High Level>DC 4.5V (Input Voltage DC 5V)
Output Pulse Low Level<DC 0.5V (Input Voltage DC 5V)
Output Pulse Duty Cycle50 ± 10%
Applicable MediaWater, Milk, Motor Oil


Feature

  1. High Performance: Brass oval gear flow sensor DN20, 30–3000 L/h range with ±5% accuracy, precise and stable flow measurement.
  2. Durability: Full brass valve body, pressure- and wear-resistant, with stainless steel parts for long service life.
  3. Leak Prevention: Reinforced sealing ring design ensures tight sealing, less leakage, and reliable operation.
  4. Stability: The imported Hall effect sensor prevents aging, delivers accurate pulse output, and supports wide industrial applications.

Dimension (Unit: mm)

brass oval gear flow sensor dimension

Output Waveform Diagram

Brass oval gear flow sensor output waveform diagram

Wiring Method

oval gear flow sensor wiring method

Application

It is widely used in petrochemical plants, oil refineries, cruise ships, and industrial flow control systems. It is suitable for measuring water, oil, and other liquids, with stable and accurate performance.

Oval gear flow sensor application

Tips: What advantages does the ATO oval gear flow sensor have over ordinary flow sensors?

Compared with ordinary turbine or paddle-type sensors, the ATO oval gear flow sensor offers ±5% high accuracy that is not easily affected by turbulence or viscosity. Its full-brass valve body (equipped with stainless steel components) ensures excellent durability, pressure resistance, and wear resistance—performance far superior to that of plastic housings. The imported Hall effect sensor provides stable and consistent pulse signals, guaranteeing reliable data output. In addition, it works well with water, oil, and other viscous liquids, making it more versatile than standard sensors limited to clean water. With its robust design and long service life, it is particularly suitable for harsh industrial environments such as petrochemical plants, refineries, and lubricant plants.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Flow sensor Information
5
Bafidar
Avatar
10/17/2025 12:21 AM
I am designing a cooling test bench and am considering using your ATO-FS-OFZAT06T flow sensor. I'd like to know if you have a data sheet for this flowmeter, which contains additional information such as operating temperature range, media contact materials, and acceptable viscosity range.
Was this review helpful? Yes No (0/0)
ATO Responded
This flow sensor's data sheet is available on our website. The operating temperature of this sensor must not exceed 80°C. The material in contact with the fluid is brass. We haven't measured the acceptable viscosity range, but the maximum acceptable viscosity requirement is that the fluid must be free-flowing, uncured, and free of impurities.
Great flow sensor
5
Daniel
Avatar
6/8/2026 7:10 PM
Using this to monitor coolant flow in a small test loop. Flow range is wide enough, and the pulse output connects straight to our PLC. Installed it a month ago, hasn't missed a beat. Good little sensor.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

DN20 brass oval gear flow sensor provides accurate flow measurement from 30–3000 L/h with ±5% precision. Built with a durable brass body and equipped with a reliable Hall effect sensor, it ensures stable pulse output and long-term durability. With low power consumption, wide temperature tolerance, and strong pressure resistance, this industrial flow sensor is widely used in petrochemical plants, refineries, tankers, and other flow control applications.

Specifications

ModelATO-OFZAT-06T
MaterialCopper valve body
Nominal DiameterDN20
Inner Diameter/Outer Diameter24.5mm/27.8mm
Accuracy Class±5%
Working Pressure≤1.2 bar
Working Temperature0-120°C
Working Voltage Range5-24VDC
Maximum Operating Current15mA (DC5V)
Load Capacity≤10mA (DC5V)
Allowable Withstand Pressure≤1.0MPa
Storage Temperature/Humidity-25~+80℃/25%~90%RH
Flow Range30-3000L/H±2%
Pulse Characteristics(Hz) = [1.2*Q] ±5%, i.e., 72 pulses per liter of water
Output Pulse High Level>DC 4.5V (Input Voltage DC 5V)
Output Pulse Low Level<DC 0.5V (Input Voltage DC 5V)
Output Pulse Duty Cycle50 ± 10%
Applicable MediaWater, Milk, Motor Oil


Feature

  1. High Performance: Brass oval gear flow sensor DN20, 30–3000 L/h range with ±5% accuracy, precise and stable flow measurement.
  2. Durability: Full brass valve body, pressure- and wear-resistant, with stainless steel parts for long service life.
  3. Leak Prevention: Reinforced sealing ring design ensures tight sealing, less leakage, and reliable operation.
  4. Stability: The imported Hall effect sensor prevents aging, delivers accurate pulse output, and supports wide industrial applications.

Dimension (Unit: mm)

brass oval gear flow sensor dimension

Output Waveform Diagram

Brass oval gear flow sensor output waveform diagram

Wiring Method

oval gear flow sensor wiring method

Application

It is widely used in petrochemical plants, oil refineries, cruise ships, and industrial flow control systems. It is suitable for measuring water, oil, and other liquids, with stable and accurate performance.

Oval gear flow sensor application

Tips: What advantages does the ATO oval gear flow sensor have over ordinary flow sensors?

Compared with ordinary turbine or paddle-type sensors, the ATO oval gear flow sensor offers ±5% high accuracy that is not easily affected by turbulence or viscosity. Its full-brass valve body (equipped with stainless steel components) ensures excellent durability, pressure resistance, and wear resistance—performance far superior to that of plastic housings. The imported Hall effect sensor provides stable and consistent pulse signals, guaranteeing reliable data output. In addition, it works well with water, oil, and other viscous liquids, making it more versatile than standard sensors limited to clean water. With its robust design and long service life, it is particularly suitable for harsh industrial environments such as petrochemical plants, refineries, and lubricant plants.

Product reviews
Flow sensor Information
5
Bafidar
Avatar
10/17/2025 12:21 AM
I am designing a cooling test bench and am considering using your ATO-FS-OFZAT06T flow sensor. I'd like to know if you have a data sheet for this flowmeter, which contains additional information such as operating temperature range, media contact materials, and acceptable viscosity range.
Was this review helpful? Yes No (0/0)
ATO Responded
This flow sensor's data sheet is available on our website. The operating temperature of this sensor must not exceed 80°C. The material in contact with the fluid is brass. We haven't measured the acceptable viscosity range, but the maximum acceptable viscosity requirement is that the fluid must be free-flowing, uncured, and free of impurities.
Great flow sensor
5
Daniel
Avatar
6/8/2026 7:10 PM
Using this to monitor coolant flow in a small test loop. Flow range is wide enough, and the pulse output connects straight to our PLC. Installed it a month ago, hasn't missed a beat. Good little sensor.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews