High Pressure Solenoid Valve, 2 Way, NC, DC 6V/12V/24V

$219.30
DC solenoid valve at affordable price for sale online. 1/4”, 3/8” and 1/2” port size of solenoid valve DC 24V can be chosen. High pressure solenoid valve adopts PTFT seals material, it can effectively root out internal leakage. Working temperature of normally closed solenoid valve between -10 ℃ and 180 ℃.
SKU: ATO-HPSV-DC
*
*
*
*
*
Free Shipping
Delivery date: 5-7 days

Note: This solenoid valve cannot be used for drinking water.

2 way solenoid valve with pilot and pressure between 0.1 MPa and 25 MPa. NC solenoid valve often used in electric power equipment and drying equipment.

Specification

(Normally open can be customized)

ModelATO-HKKB-08ATO-HKKB-08ATO-HKKB-10ATO-HKKB-15
Port Size1/4"1/4"3/8"1/2"
Orifice1.222.53
Cv0.030.090.150.24
Min Pressure0.1 MPa0.1 MPa0.1 MPa0.1 MPa
Max Pressure (AC 24VA)25 MPa25 MPa25 MPa25 MPa
Max Pressure (DC 18W)25 MPa25 MPa25 MPa10 MPa
Seals MaterialPTFE
VoltageDC 6V/12V/24V
CoilS21B
Body MaterialSS304
Port ThreadBSPP, BSPT, NPT
Mediumwater, hot water, compressed air, oil
Temperature-10 ℃ ~ 180 ℃
Tolerance±10%


Dimension (Unit: mm)

High pressure solenoid valve dimension

SizeA (mm)C (mm)
HKKB-1/4"53148
HKKB-3/8"53148
HKKB-1/2"53148

Tips: Working Principle of High Pressure Solenoid Valve

At different locations opening holes, each hole leads to different tubing, cavity valve is among, both sides are two electromagnets, which face the magnet coil electricity body will be attracted to which side, by controlling the movement of the valve body blocked or leakage of different discharge of oil hole, and the oil hole is always open, hydraulic fluid will enter the different oil drain, and then through the oil pressure to push oil just the pistons, The piston drives the piston rod, and the piston rod drives the mechanical device. In this way, the current of the electromagnet controls the mechanical movement of the high pressure solenoid valve.

Working Principle and Disassembly of Solenoid Valve

In this video, we will introduce the basic working principle and disassembly process of the solenoid valve.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Solenoid valve works great
5
Elfie
Avatar
12/8/2022 7:18 PM
I purchased the 12 V pressure valve 2 months ago. Use it to drain water from an air compressor and it still works as described. I would recommend this solenoid valve to you. Good value for price.
Was this review helpful? Yes No (0/0)
High-speed pneumatic solenoid valve
5
Orville
Avatar
10/7/2025 11:55 PM
I'm looking for a high-speed pneumatic solenoid valve capable of handling compressed CO2 pressures up to 1000 psi. Could you please help me select the right product? Thank you for your time!
Was this review helpful? Yes No (0/0)
ATO Responded
How fast do you want the solenoid valve to operate? We recommend the high-pressure solenoid valve, 2-way, SKU: ATO-HPSV-DC.
For high concentration hydrogen peroxide
4
Tokenia
Avatar
10/26/2026 1:40 AM
I purchased a high-pressure solenoid valve (ATO-HPSV-DC) and would like to know if it can withstand high concentrations of hydrogen peroxide.
Was this review helpful? Yes No (0/0)
ATO Responded
If the medium is high-concentration hydrogen peroxide, we do not recommend using it with this high-pressure solenoid valve; only normal concentrations of hydrogen peroxide are acceptable.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Note: This solenoid valve cannot be used for drinking water.

2 way solenoid valve with pilot and pressure between 0.1 MPa and 25 MPa. NC solenoid valve often used in electric power equipment and drying equipment.

Specification

(Normally open can be customized)

ModelATO-HKKB-08ATO-HKKB-08ATO-HKKB-10ATO-HKKB-15
Port Size1/4"1/4"3/8"1/2"
Orifice1.222.53
Cv0.030.090.150.24
Min Pressure0.1 MPa0.1 MPa0.1 MPa0.1 MPa
Max Pressure (AC 24VA)25 MPa25 MPa25 MPa25 MPa
Max Pressure (DC 18W)25 MPa25 MPa25 MPa10 MPa
Seals MaterialPTFE
VoltageDC 6V/12V/24V
CoilS21B
Body MaterialSS304
Port ThreadBSPP, BSPT, NPT
Mediumwater, hot water, compressed air, oil
Temperature-10 ℃ ~ 180 ℃
Tolerance±10%


Dimension (Unit: mm)

High pressure solenoid valve dimension

SizeA (mm)C (mm)
HKKB-1/4"53148
HKKB-3/8"53148
HKKB-1/2"53148

Tips: Working Principle of High Pressure Solenoid Valve

At different locations opening holes, each hole leads to different tubing, cavity valve is among, both sides are two electromagnets, which face the magnet coil electricity body will be attracted to which side, by controlling the movement of the valve body blocked or leakage of different discharge of oil hole, and the oil hole is always open, hydraulic fluid will enter the different oil drain, and then through the oil pressure to push oil just the pistons, The piston drives the piston rod, and the piston rod drives the mechanical device. In this way, the current of the electromagnet controls the mechanical movement of the high pressure solenoid valve.

Product reviews
Solenoid valve works great
5
Elfie
Avatar
12/8/2022 7:18 PM
I purchased the 12 V pressure valve 2 months ago. Use it to drain water from an air compressor and it still works as described. I would recommend this solenoid valve to you. Good value for price.
Was this review helpful? Yes No (0/0)
High-speed pneumatic solenoid valve
5
Orville
Avatar
10/7/2025 11:55 PM
I'm looking for a high-speed pneumatic solenoid valve capable of handling compressed CO2 pressures up to 1000 psi. Could you please help me select the right product? Thank you for your time!
Was this review helpful? Yes No (0/0)
ATO Responded
How fast do you want the solenoid valve to operate? We recommend the high-pressure solenoid valve, 2-way, SKU: ATO-HPSV-DC.
For high concentration hydrogen peroxide
4
Tokenia
Avatar
10/26/2026 1:40 AM
I purchased a high-pressure solenoid valve (ATO-HPSV-DC) and would like to know if it can withstand high concentrations of hydrogen peroxide.
Was this review helpful? Yes No (0/0)
ATO Responded
If the medium is high-concentration hydrogen peroxide, we do not recommend using it with this high-pressure solenoid valve; only normal concentrations of hydrogen peroxide are acceptable.
Only registered users can write reviews
Customers who bought this item also bought

Single Point Load Cell, 300g/1kg/3kg/ 10kg/60kg/100kg/200kg to 500kg

ATO-LC-SP01
$79.89
Single point load cell is widely used for weighing scale or pricing scale. Single point load cell is suited to use in flat and low space, with parallel beam structure, good stability, good output symmetry, high accuracy, low temperature drift and overload protection.