Fixed Oxygen (O2) Gas Detector, 0 to 25% / 30% Vol

$434.77
Fixed gas detector for detecting oxygen concentration. Measuring range 0~25% or 0~30% for selection, output signal 4-20mA and RS485, high accuracy 3% F.S. O2 gas detector has sound and light alarm, real-time display, remote control, small size, lightweight, low price.
SKU: GD300-O2
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Fixed oxygen gas detector for sale. Optional measuring range 0~25% or 0~30%, output signal 4-20mA & RS485. The O2 gas detector can 24 hours online for oxygen concentration detecting, supports remote control, sound and light alarm, affordable price, reliable manufacturer.

Features

  • Oxygen gas detector adopts high precision sensor for accurate gas leak detection.
  • Oxygen gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The O2 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The oxygen gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The O2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-O2
Detection PrincipleElectrochemistry
GasOxygen (O2)
Range (Optional)0-25% VOL, 0-30% VOL, 0-100% VOL
Resolution0.01% VOL (0-25/30% VOL), or 0.1% VOL (0-100% VOL)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Oxygen (02) Gas Detector Details

Tips: Why you need an oxygen gas detector?

Oxygen detection is very important for entering confined spaces and entering certain open spaces below the ground. Other gases with higher density than air (such as gasoline, hydrogen sulfide, etc.) will accumulate in the downward direction, thereby displacing O2 in the space. There are two concentration points to consider in the detection of oxygen concentration: one is that too low O2 concentration will cause suffocation, and the other is that excessive oxygen exceeding the constant may cause unimaginable acceleration and enhancement of combustion or other chemical reactions. The concentration of oxygen in normal air is about 20.9%, and the balance (over 78%) is mainly nitrogen, and the rest includes a small amount of water vapor, carbon monoxide and other gases.

Most confined space standards and law enforcement agencies, such as OSHA, use the volumetric concentration of O2 to determine whether it is insufficient, and the usual lower limit is 19.5%. This is also the lowest alarm point set by most manufacturers on the oxygen gas detector. Some law enforcement agencies also use partial pressure of gas instead of concentration to indicate insufficient oxygen. In this case, if the O2 partial pressure is lower than 16.3 kPa or 122 mHg, it is deemed insufficient (16 kPa oxygen partial pressure is approximately equivalent to 16.3% oxygen concentration at sea level). The reason for using partial pressure is that the human body relies more on oxygen partial pressure rather than concentration for breathing.

Gas Detector 3-Wire System

In the realm of gas detection systems, the 3-wire configuration offers a robust wiring solution, especially for applications requiring analog output. This video will show you the 3-wire gas detector wiring.

Gas Detector 4-Wire System

The wiring of the 4-wire gas detector supports the RS485 interface Modbus RTU communication mode. This video will show you the 4-wire gas detector wiring.

Using Cloud Data and 4G for Fixed Gas Detectors

This video will show you about the applications of cloud data and 4G transmission for fixed gas detectors.

Monitoring Combustible Gas in Pipelines

This video will show you how to monitoring combustible gas in pipelines.

Fixed Gas Detector Remote Integrated Control

In this video, the process of remote integrated control of a fixed gas detector is introduced.

How to Calibrate a Fixed Gas Detector?

This video introduces the zero calibration process of a fixed gas detector. When the air is clean, press the menu first, then press the "+" key to enter F04, then press the OK key, and then press the BACK key. The detected data will become zero. Prepare the standard gas, we use isobutane for calibration.

Step 1: Press the menu, then press the "+" key to enter F07, change the data to the same as the standard gas value, and press OK.
Step 2: Press the menu, then press the "+" key to enter F08, now you will see it shows 0, change it to 1, and then press the OK key to return.
Step 3: Connect the sensor to the standard gas, the gas flow rate is 500mL/min, and press the OK key after the data stabilizes.

Product reviews
Can you help me find a suitable instrument for measuring formaldehyde gas?
5
Bpayne
Avatar
9/13/2021 9:30 PM
I want 7 of these units to be able to monitor from 0 to 100ppm of formaldehyde. We will use these inside a hatcher to monitor the levels as the chickens hatch out. I need to monitor for 3 days and I need the data to be able to be graphed out. Can you help me? Do you have a picture of the graph or does it just get exported to excel and then I have to do it myself?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The most common working time of our Portable Formaldehyde (CH2O) Gas Detector is 24 hours (after full charge). Therefore, if you want to exceed 72 hours working hours, then we recommend using fixed (CH2O) gas detectors, it can run continuously for a long time.
2. Whether you will use our portable or fixed gas detector, you can only export the measurement data to the excel file without providing the historical graph.
I have a question about your gas detector
5
Wong
Avatar
9/28/2021 9:09 PM
I am Watanabe from Japan and I'm a postgraduate student. I'm writing to you for the first time.
I'm contacting you to enquire about <Gas-H2>.
I'm interested in your product and I want to use it to measure H2 in the air. So I have questions about your product.
Is this machine high precision? It's said that there is about 0.5‰H2 in the air, so I wonder whether this machine can measure by after the decimal point.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our gas detector can measure H2 in the air, and you can choose the measurement range 0-10 ppm (accuracy 0.001 ppm), or 0-500 ppm (accuracy 0.1 ppm).
Good performance
5
Zephyr
Avatar
10/16/2023 11:58 PM
I recently acquired the Fixed Oxygen (O2) Gas Detector for our industrial facility, and I couldn't be more pleased with its performance. Its precision in monitoring oxygen levels within a broad measurement range, coupled with straightforward installation, has streamlined our safety protocols.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Fixed oxygen gas detector for sale. Optional measuring range 0~25% or 0~30%, output signal 4-20mA & RS485. The O2 gas detector can 24 hours online for oxygen concentration detecting, supports remote control, sound and light alarm, affordable price, reliable manufacturer.

Features

  • Oxygen gas detector adopts high precision sensor for accurate gas leak detection.
  • Oxygen gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The O2 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The oxygen gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The O2 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-O2
Detection PrincipleElectrochemistry
GasOxygen (O2)
Range (Optional)0-25% VOL, 0-30% VOL, 0-100% VOL
Resolution0.01% VOL (0-25/30% VOL), or 0.1% VOL (0-100% VOL)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12-36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Oxygen (02) Gas Detector Details

Tips: Why you need an oxygen gas detector?

Oxygen detection is very important for entering confined spaces and entering certain open spaces below the ground. Other gases with higher density than air (such as gasoline, hydrogen sulfide, etc.) will accumulate in the downward direction, thereby displacing O2 in the space. There are two concentration points to consider in the detection of oxygen concentration: one is that too low O2 concentration will cause suffocation, and the other is that excessive oxygen exceeding the constant may cause unimaginable acceleration and enhancement of combustion or other chemical reactions. The concentration of oxygen in normal air is about 20.9%, and the balance (over 78%) is mainly nitrogen, and the rest includes a small amount of water vapor, carbon monoxide and other gases.

Most confined space standards and law enforcement agencies, such as OSHA, use the volumetric concentration of O2 to determine whether it is insufficient, and the usual lower limit is 19.5%. This is also the lowest alarm point set by most manufacturers on the oxygen gas detector. Some law enforcement agencies also use partial pressure of gas instead of concentration to indicate insufficient oxygen. In this case, if the O2 partial pressure is lower than 16.3 kPa or 122 mHg, it is deemed insufficient (16 kPa oxygen partial pressure is approximately equivalent to 16.3% oxygen concentration at sea level). The reason for using partial pressure is that the human body relies more on oxygen partial pressure rather than concentration for breathing.

Product reviews
Can you help me find a suitable instrument for measuring formaldehyde gas?
5
Bpayne
Avatar
9/13/2021 9:30 PM
I want 7 of these units to be able to monitor from 0 to 100ppm of formaldehyde. We will use these inside a hatcher to monitor the levels as the chickens hatch out. I need to monitor for 3 days and I need the data to be able to be graphed out. Can you help me? Do you have a picture of the graph or does it just get exported to excel and then I have to do it myself?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The most common working time of our Portable Formaldehyde (CH2O) Gas Detector is 24 hours (after full charge). Therefore, if you want to exceed 72 hours working hours, then we recommend using fixed (CH2O) gas detectors, it can run continuously for a long time.
2. Whether you will use our portable or fixed gas detector, you can only export the measurement data to the excel file without providing the historical graph.
I have a question about your gas detector
5
Wong
Avatar
9/28/2021 9:09 PM
I am Watanabe from Japan and I'm a postgraduate student. I'm writing to you for the first time.
I'm contacting you to enquire about <Gas-H2>.
I'm interested in your product and I want to use it to measure H2 in the air. So I have questions about your product.
Is this machine high precision? It's said that there is about 0.5‰H2 in the air, so I wonder whether this machine can measure by after the decimal point.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our gas detector can measure H2 in the air, and you can choose the measurement range 0-10 ppm (accuracy 0.001 ppm), or 0-500 ppm (accuracy 0.1 ppm).
Good performance
5
Zephyr
Avatar
10/16/2023 11:58 PM
I recently acquired the Fixed Oxygen (O2) Gas Detector for our industrial facility, and I couldn't be more pleased with its performance. Its precision in monitoring oxygen levels within a broad measurement range, coupled with straightforward installation, has streamlined our safety protocols.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Portable Oxygen (O2) Gas Detector, 0 to 30% Vol

GD200-O2
$479.22
Portable oxygen detector, ideal for monitoring O2 gas concentration in the range of 0 to 30% Vol or 0 to 100% Vol, with sound, light and vibrating alarm, light and compact, easy to setting and operation, long working time with large capacity battery, high accuracy and low price.