Fixed Methane (CH4) Gas Detector, 0 to 100% LEL

$2,093.23
Buy fixed methane gas detector online at good price. Measuring range 0-100% LEL, resolution 1% LEL, optional output signal 4-20mA and RS485, high accuracy 3% F.S. CH4 gas detector 24-hour works to detect and monitor methane concentration, sound and light alarm, real-time display, remote control is available.
SKU: GD300-CH4
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Low price methane gas detector for sale. Measurement range 0-100% LEL, supports remote control with output signal 4-20mA and RS485. The CH4 gas detector has fixed design, which is used in methane concentration detecting and monitoring, sound and light alarm, real-time display, small size, lightweight, convenient mounting.

Features

  • Methane gas detector adopts high precision sensor for accurate gas leak detection.
  • Methane gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The CH4 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The methane gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The CH4 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-CH4
Detection PrincipleInfrared
GasMethane (CH4)
Range0-100% LEL, 0-50% VOL, 0-100% VOL
Resolution1% LEL (0-100%LEL), 0.01% VOL (0-50%VOL), 0.1% VOL (0-100%VOL)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12~36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Methane (CH4) Gas Detector Details

Tips: How to improve the service life of methane gas detector?

  • The methane gas detector should be calibrated and tested regularly.
    When replacing the probe of CH4 gas detector, in addition to a certain sensor activation time, the instrument must be recalibrated. In addition, before using the methane gas detector, use the standard gas for response detection to ensure protection of the instrument.
  • Pay attention to the interference between other sensors and the methane gas detector.
    Although a composite gas detector can detect multiple gases at the same time, the fixed gas detector is not suitable for any combination of toxic and harmful gases. Generally speaking, each gas detector corresponds to a specific detection gas, but any gas detector cannot be absolutely effective.
  • Pay attention to the life of methane gas detector.
    CH4 gas detector has a certain service life. Generally, in portable gas detectors, LEL sensors have a longer life span and can generally be used for about three years. The life of the photoionization detector is four years or longer. The lifetime of electrochemical specific gas detectors is relatively short, generally one to two years. The life span of the oxygen sensor is short, about a year or so.

Gas Detector 3-Wire System

In the realm of gas detection systems, the 3-wire configuration offers a robust wiring solution, especially for applications requiring analog output. This video will show you the 3-wire gas detector wiring.

Gas Detector 4-Wire System

The wiring of the 4-wire gas detector supports the RS485 interface Modbus RTU communication mode. This video will show you the 4-wire gas detector wiring.

Using Cloud Data and 4G for Fixed Gas Detectors

This video will show you about the applications of cloud data and 4G transmission for fixed gas detectors.

Monitoring Combustible Gas in Pipelines

This video will show you how to monitoring combustible gas in pipelines.

Fixed Gas Detector Remote Integrated Control

In this video, the process of remote integrated control of a fixed gas detector is introduced.

How to Calibrate a Fixed Gas Detector?

This video introduces the zero calibration process of a fixed gas detector. When the air is clean, press the menu first, then press the "+" key to enter F04, then press the OK key, and then press the BACK key. The detected data will become zero. Prepare the standard gas, we use isobutane for calibration.

Step 1: Press the menu, then press the "+" key to enter F07, change the data to the same as the standard gas value, and press OK.
Step 2: Press the menu, then press the "+" key to enter F08, now you will see it shows 0, change it to 1, and then press the OK key to return.
Step 3: Connect the sensor to the standard gas, the gas flow rate is 500mL/min, and press the OK key after the data stabilizes.

Product reviews
Gas detector order
5
Hcobb
Avatar
9/12/2021 9:16 PM
We are looking for a way to sniff out N2 leaks on a transformer by moving the detector along welds, the N2 system regulator and plumbing is this a good tool for that application?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, if the N2 system regulator is in a normal air environment, which means that the welds point of pipeline is in the normal air but no other mixed gas, then the unit N2 portable detector 0-100%VOL can work for that, with no problem at all.
SKU: ATO-GAS-N2
See specs, price, and you can order by credit card on: https://www.ato.com/portable-n2-gas-detector
Free shipping.
Landfill dectection
5
Kye
Avatar
11/28/2023 5:00 AM
I'm planning to detect landfill methane emission. I'll install instrument outside and dectect continously. Also I want to save data (connect PC)

Is this product suitable for my plan? If there any other suitable product, please tell me

Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Our fixed methane (CH4) gas detector is not supported to be directly exposed outdoors, because the protection level is not enough and the rain will damage the equipment. Of course, you can make a rain shield by yourself (without affecting the air circulation, as well as the rain can not erode the product).
Looking for CH4 detector
5
Amelia
Avatar
1/8/2024 12:14 AM
We are interested in the stand-alone version with  the ability to interrogate, ideally a digital signal.  We are looking for the ability to measure very low methane concentrations in air.  Something in the range of 0-25% would be a good start.
Was this review helpful? Yes No (0/0)
ATO Responded
If you need "real time measurement software", we recommend the new version of the portable gas detector GD3000-CH4.
It has three measuring ranges: 0-10000ppm, 20-100%LEL, 5-100%VOL---the lowest can be measured is 1ppm. This version comes with Bluetooth wireless or LORA wireless.
Prof Rahman
5
Abdur
Avatar
8/23/2026 10:51 PM
i am interest to know the cost of newer version (GD3000 CH4) of gas dectector product. please clarify by installing this devise, can we exactly measure the quantity of methan gas present in that enclosed as well as open cattle shed? looking for your kind response
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, in principle. We have measurement ranges of 0-5000ppm, 0-10000ppm, 0-100%LEL, and 0-100%VOL. If you know the range you need to measure, please tell us and email us at service@ato.com to get a quote.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Low price methane gas detector for sale. Measurement range 0-100% LEL, supports remote control with output signal 4-20mA and RS485. The CH4 gas detector has fixed design, which is used in methane concentration detecting and monitoring, sound and light alarm, real-time display, small size, lightweight, convenient mounting.

Features

  • Methane gas detector adopts high precision sensor for accurate gas leak detection.
  • Methane gas detector is equipped with 3-wire system 4-20mA analog output, relay output, RS485 output (optional).
  • The CH4 gas detector is compatible with various controlled alarms, PLC, DCS and other control system, and can be remote monitored.
  • Explosion-proof design, fast, relaible and stable.
  • Infrared ray controller can remote control the alarm point settings, zero calibration, and address modification.
  • Two-stage alarm with sound and light, and the alarm point is settable.
  • The methane gas detector has self-calibration function, and three standard keys will be used to realize on-site maintenance.
  • The CH4 gas detector can output one or two on-off signals, can drive ventilator, solenoid valve or other external devices.

Specification

ModelGD300-CH4
Detection PrincipleInfrared
GasMethane (CH4)
Range0-100% LEL, 0-50% VOL, 0-100% VOL
Resolution1% LEL (0-100%LEL), 0.01% VOL (0-50%VOL), 0.1% VOL (0-100%VOL)
Calibration KitGas pressure regulator (calibration gas cylinder NOT included)
Accuracy≤±3% F.S.
Response Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Signal Output (Optional)4-20mA and RS485
Relay output: one group of relay output (1NO+1NC, 5A/30V) for one alarm (default), or two groups of relay output (2NO+2NC, 5A/30V) for high/low alarm (optional).
AlarmsSound, light
DisplayHigh light nixie tube display
InstallationWall-mounted, piping type, flow-type (according to the detected environment)
ConnectionPower connection type: G1/2 male thread explosion-proof flexible pipe
Pipe-mounted type: M45*P2.0
Operating Time24h
Explosion-proof GradeII 2G Ex db IIC T4 Gb
Protection GradeIP65
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Working Voltage12~36V DC
Case MaterialDie-casting aluminum housing
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Dimension206*179*90mm
Weight≤1.6kg
Power AdapterInput 100-240VAC 50/60Hz, Output 24VDC 1A (Optional USA plug, Europe plug, AU plug or UK plug)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube


Notes

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

Dimensions (Unit: mm)

Fixed gas detector dimensions

Installation Guide

The following precautions apply when connecting the GD300 series fixed gas detector to a pipeline:

  1. Working pressure should be stable at 1 bar ±10%, and the flow rate should be controlled at 300 mL/min.
  2. Working temperature is -20°C to +50°C.
  3. Working humidity is 0–95% RH. When the humidity is above 60% RH, it is recommended to use a dehumidifier or add a filter. When the humidity is above 95% RH, the gas is essentially saturated with water, making measurement impossible.
  4. The gas detector should be installed indoors. If it is installed outdoors, a rain cover should be added to protect the entire instrument.
  5. For the second pipeline connection method of the GD300 gas detector, the pipe-mounted installation, the detector mounting thread size is M45 × P2.0. During installation, hold the detector with both hands, keeping the sensor parallel to the mounting thread. Align it with the threaded port, rotate the detector clockwise, and install it in the desired position. To prevent gas leakage at the threaded connection, an appropriate amount of thread seal tape can be wrapped around the sensor head thread before installation.

***Other Common Gases and Ranges Available for Fixed Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/10/50/100/200/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/9999ppm, 0-2/5/10/20/25/30/50/100%VOL0.1ppm/1ppm/0.001%VOL/0.01%VOL/0.1%VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Combustible Gas (EX)0-100%LEL1%LEL
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100%LEL1%LEL
Hydrogen (H2)0-10/20/500/1000/2000/5000/9999ppm, 0-2/4% VOL, 0-100% LEL0.1ppm/1ppm/0.001%VOL/1%LEL
Hydrogen Chloride (HCL)0-10/20/50/100/200ppm0.01ppm/0.1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Sulfide (H2S)0-5/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Methane (CH4)0-50/100%VOL, 0-100%LEL0.01%VOL/0.1%VOL/1%LEL
Nitric Oxide (NO)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99/0-100%VOL0.01%VOL/0.1%VOL
Nitrogen Dioxide (NO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Nitrogen Oxides (NOX)0-1/5/10/20/50/100/250/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25/30/100%VOL0.01%VOL/0.1%VOL
Ozone (O3)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-1/5/10/20/50/100/500/1000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm

Note: Some common gases and the measuring ranges are listed in the above table. For more information, please feel free to contact us.

Details

Fixed Methane (CH4) Gas Detector Details

Tips: How to improve the service life of methane gas detector?

  • The methane gas detector should be calibrated and tested regularly.
    When replacing the probe of CH4 gas detector, in addition to a certain sensor activation time, the instrument must be recalibrated. In addition, before using the methane gas detector, use the standard gas for response detection to ensure protection of the instrument.
  • Pay attention to the interference between other sensors and the methane gas detector.
    Although a composite gas detector can detect multiple gases at the same time, the fixed gas detector is not suitable for any combination of toxic and harmful gases. Generally speaking, each gas detector corresponds to a specific detection gas, but any gas detector cannot be absolutely effective.
  • Pay attention to the life of methane gas detector.
    CH4 gas detector has a certain service life. Generally, in portable gas detectors, LEL sensors have a longer life span and can generally be used for about three years. The life of the photoionization detector is four years or longer. The lifetime of electrochemical specific gas detectors is relatively short, generally one to two years. The life span of the oxygen sensor is short, about a year or so.
Product reviews
Gas detector order
5
Hcobb
Avatar
9/12/2021 9:16 PM
We are looking for a way to sniff out N2 leaks on a transformer by moving the detector along welds, the N2 system regulator and plumbing is this a good tool for that application?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, if the N2 system regulator is in a normal air environment, which means that the welds point of pipeline is in the normal air but no other mixed gas, then the unit N2 portable detector 0-100%VOL can work for that, with no problem at all.
SKU: ATO-GAS-N2
See specs, price, and you can order by credit card on: https://www.ato.com/portable-n2-gas-detector
Free shipping.
Landfill dectection
5
Kye
Avatar
11/28/2023 5:00 AM
I'm planning to detect landfill methane emission. I'll install instrument outside and dectect continously. Also I want to save data (connect PC)

Is this product suitable for my plan? If there any other suitable product, please tell me

Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Our fixed methane (CH4) gas detector is not supported to be directly exposed outdoors, because the protection level is not enough and the rain will damage the equipment. Of course, you can make a rain shield by yourself (without affecting the air circulation, as well as the rain can not erode the product).
Looking for CH4 detector
5
Amelia
Avatar
1/8/2024 12:14 AM
We are interested in the stand-alone version with  the ability to interrogate, ideally a digital signal.  We are looking for the ability to measure very low methane concentrations in air.  Something in the range of 0-25% would be a good start.
Was this review helpful? Yes No (0/0)
ATO Responded
If you need "real time measurement software", we recommend the new version of the portable gas detector GD3000-CH4.
It has three measuring ranges: 0-10000ppm, 20-100%LEL, 5-100%VOL---the lowest can be measured is 1ppm. This version comes with Bluetooth wireless or LORA wireless.
Prof Rahman
5
Abdur
Avatar
8/23/2026 10:51 PM
i am interest to know the cost of newer version (GD3000 CH4) of gas dectector product. please clarify by installing this devise, can we exactly measure the quantity of methan gas present in that enclosed as well as open cattle shed? looking for your kind response
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, in principle. We have measurement ranges of 0-5000ppm, 0-10000ppm, 0-100%LEL, and 0-100%VOL. If you know the range you need to measure, please tell us and email us at service@ato.com to get a quote.
Only registered users can write reviews