Specification

Basic ParametersModelATO-WPB6F
Display MethodDouble 5 Digit
VoltageV0100~240V AC 50/60Hz
V110~24V AC 50/60Hz, 10~24V DC
Power ConsumptionV0Below 10W
V1AC: Below 6VA; DC: Below 5W
Allowable Voltage Range90%~110% of Voltage
Insulation Resistance≥100MΩ
Dielectric Strength2000V AC
Anti-InterferenceIEC61000-4-2 (Electrostatic Discharge), Level III
IEC61000-4-4 (Electrical Fast Transient Burst), Level III
IEC61000-4-5 (Surge), Level III
Protection GradeIP65
Operating EnvironmentAmbient Temperature-10~50℃ (Storage: -25~65℃)
Environmental Humidity35~85%RH, No Condensation
Installation LocationIndoors, Height <2000m
Comparison Output2 points OC Gate Output, 100mA (Max)
Input ParametersSensor Power SupplyP1DC 10V±2%, 200mA (Max) (Default)
P2DC 5V±2%, 100mA (Max)
Input Impedance>10MΩ
Conversion MethodSignal-Delta
Measurement & Control Speed240, 480, 960, 1920 times/second
Nonlinearity±0.05%F·S (Measurement & Control: 15bps)
Gain Drift<10ppm/℃
Maximum Display Accuracy1/100000
Input SignalProportional Measurement, Connected to 4-Wire Strain Sensor
Contact Input1 External Switch Input
Optional ParametersAnalog OutputM1Current Output 4-20mA, 0-10mA, 0-20mA
M2Voltage Output 1-5V, 0-5V
M3Voltage Output 0-10V
Communication InterfaceR1RS232 Interface, Modbus-RTU and TC ASCⅡ Protocol
R2RS485 Interface, Modbus-RTU and TC ASCⅡ Protocol


Dimension (Unit: mm)

Double 5 digit display controller dimension

Switch Input Wiring Diagram

Double 5 digit display controller switch input wiring diagram

Switch Output Wiring Diagram

Double 5 digit display controller switch output wiring diagram

Tips: What is a double 5 digit display controller used for?

A double 5 digit display controller is a specialized electronic device used primarily for load cell applications. Load cells are sensors that measure force or weight, and these controllers provide a convenient way to monitor and display the measurement data. The double 5 digit description typically means that the controller has two separate displays, each with the capacity to show five digits, providing a high level of precision.

These display controllers are essential in various industries, including manufacturing, logistics, and agriculture, where accurate weight measurements are critical. They typically feature user-friendly interfaces and options for calibration and data processing. Users can configure parameters, set alarms, and access recorded data. This type of controller is often integrated into larger systems for automated process control or inventory management, ensuring efficient and reliable operation by providing real-time load data in an easily readable format.

Product reviews
Regarding the controller
5
Skoog
Avatar
9/18/2025 8:37 PM
Regarding the ATO-DDC-CHB6F dynamometer, is it possible to reset the display or change the display mode (for example, from peak to valley mode) via a PLC (programmable logic controller) without manually pressing buttons?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The ATO-DDC-CHB6F dynamometer can be reset to zero via the PLC.
2. Regarding display content modification: For a single-screen display, only the default display content at startup can be modified via communication. For a dual-screen display, the display content of the second window can be modified via communication.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO double 5 digit display controller is a digital panel meter designed to control and drive a 5 digit display unit, which can be used with load cells, force sensors and weighing sensors.

Specification

Basic ParametersModelATO-WPB6F
Display MethodDouble 5 Digit
VoltageV0100~240V AC 50/60Hz
V110~24V AC 50/60Hz, 10~24V DC
Power ConsumptionV0Below 10W
V1AC: Below 6VA; DC: Below 5W
Allowable Voltage Range90%~110% of Voltage
Insulation Resistance≥100MΩ
Dielectric Strength2000V AC
Anti-InterferenceIEC61000-4-2 (Electrostatic Discharge), Level III
IEC61000-4-4 (Electrical Fast Transient Burst), Level III
IEC61000-4-5 (Surge), Level III
Protection GradeIP65
Operating EnvironmentAmbient Temperature-10~50℃ (Storage: -25~65℃)
Environmental Humidity35~85%RH, No Condensation
Installation LocationIndoors, Height <2000m
Comparison Output2 points OC Gate Output, 100mA (Max)
Input ParametersSensor Power SupplyP1DC 10V±2%, 200mA (Max) (Default)
P2DC 5V±2%, 100mA (Max)
Input Impedance>10MΩ
Conversion MethodSignal-Delta
Measurement & Control Speed240, 480, 960, 1920 times/second
Nonlinearity±0.05%F·S (Measurement & Control: 15bps)
Gain Drift<10ppm/℃
Maximum Display Accuracy1/100000
Input SignalProportional Measurement, Connected to 4-Wire Strain Sensor
Contact Input1 External Switch Input
Optional ParametersAnalog OutputM1Current Output 4-20mA, 0-10mA, 0-20mA
M2Voltage Output 1-5V, 0-5V
M3Voltage Output 0-10V
Communication InterfaceR1RS232 Interface, Modbus-RTU and TC ASCⅡ Protocol
R2RS485 Interface, Modbus-RTU and TC ASCⅡ Protocol


Dimension (Unit: mm)

Double 5 digit display controller dimension

Switch Input Wiring Diagram

Double 5 digit display controller switch input wiring diagram

Switch Output Wiring Diagram

Double 5 digit display controller switch output wiring diagram

Tips: What is a double 5 digit display controller used for?

A double 5 digit display controller is a specialized electronic device used primarily for load cell applications. Load cells are sensors that measure force or weight, and these controllers provide a convenient way to monitor and display the measurement data. The double 5 digit description typically means that the controller has two separate displays, each with the capacity to show five digits, providing a high level of precision.

These display controllers are essential in various industries, including manufacturing, logistics, and agriculture, where accurate weight measurements are critical. They typically feature user-friendly interfaces and options for calibration and data processing. Users can configure parameters, set alarms, and access recorded data. This type of controller is often integrated into larger systems for automated process control or inventory management, ensuring efficient and reliable operation by providing real-time load data in an easily readable format.

Product reviews
Regarding the controller
5
Skoog
Avatar
9/18/2025 8:37 PM
Regarding the ATO-DDC-CHB6F dynamometer, is it possible to reset the display or change the display mode (for example, from peak to valley mode) via a PLC (programmable logic controller) without manually pressing buttons?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The ATO-DDC-CHB6F dynamometer can be reset to zero via the PLC.
2. Regarding display content modification: For a single-screen display, only the default display content at startup can be modified via communication. For a dual-screen display, the display content of the second window can be modified via communication.
Only registered users can write reviews
Customers who bought this item also bought

Compression Load Cell, 300kg/500kg/2 ton/10 ton/15 ton to 30 ton

ATO-LC-TC03
$157.78
Compression load cell is special designed for weight measurement, with compact structure, pouring sealant or welding seal, low height, all stainless steel, good anti-eccentric load performance and corrosion-resistant. Load cell can be applied for platform scale, truck scale, rail weighbridge and automated measurement and control areas.

Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485

ATO-LCTR-OAR
$109.85
High precision load cell amplifier has a 6 digit LED display, output signal 4-20mA/ 0-5V/ 0-10V/ RS485. There are 3 keys for parameter settings. Digital load cell amplifier can be calibrated on-line by its 3 keys. The setting parameters include zero, capacity, communication rate, division value, decimal digits, etc.

Load Cell Junction Box for Scales, 2/3/4/6/8/10 Inlets to 1 Outlet

ATO-LCBOX-10I
$66.67
Multi-channel load cell junction box has 2/3/4/6/8/10 inlets and 1 outlet, aluminum alloy casing, good anti-interference, special for waterproof sealing joint, waterproof and dustproof rubber gasket for cover, easy to assemble and debug. Each channel can be adjusted balance to prevent damage to the sensor caused by inductive lightning and surge signals.