Digital Panel Meter for RTD/Pressure/Level Sensor, Double 4 Digit

$97.88
Intelligent digital panel meter has double 4 digit LED for PV and SV display. Digital display controller also has optional fuctions of 2 alarms, 1 transmit analog signal or RS485/232 output, additional power supply (DC 24V) for sensors. Digital panel meter can be used for various sensors and transmitters, such as temperature sensor (themocouple B/S/K/E/T/J/R/N type and RTD Cu50/Cu100/Pt100), pressure sensor, flow sensor, level sensor, displacement sensor (0-500Ω/0-350Ω output), transmitter (0-20mA/4-20mA/0-5V/0-10V output), etc.
SKU: ATO-DPM-USD4D
*
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

Digital panel meter has double 4 digit LED for PV and SV display. Digital display controller can be used for various sensors and transmitters, such as temperature sensor, pressure sensor, flow sensor, level sensor, displacement sensor, AC/DC current sensor, transmitter with 4-20mA/0-5V output, etc.

Specification:

BasicsModelATO-DPM-USD4D-1100
Dimension (W*H*L) *A: 160*80*110mm horizontal, hole size 152*76mm
B: 80*160*110mm vertical, hole size 76*152mm
C: 96*96*110mm, 92*92mm
D: 96*48*110mm horizontal, hole size 92*45mm
E: 48*96*110mm vertical, hole size 45*92mm
F: 72*72*110mm, hole size 68*68mm
H: 48*48*110mm, hole size 45*45mm
Shipping weight2 kg
Technical parametersDisplay range-1999~1999
Measurement accuracy0.3%FS
Display methodOne channel double 4 digit LED display (PV and SV)
Input signal *Thermocouple, RTD, linear resistance, presssure sensor, level sensor, current sensor, voltage sensor, analog signal, etc. (See details in the selection chart.)
Output signal *A0: No output
A1: 4-20mA (RL≤600Ω)
A2: 1-5V (RL≥250KΩ)
A3: 0-10mA (RL≤1.2KΩ)
A4: 0-5V (RL≥250KΩ)
A5: 0-20mA (RL≤600Ω)
A6: 0-10V (RL≥4KΩ)
T: RS485/232 (Modbus)
Alarm mode*R0: No alarm output
R1: 1 alarm relay
R2: 2 alarm relays
Note: 1 alarm relay includes: NO (AC 220V/3A, DC 30V/5A), 2 alarm relays include: NO+NO (AC 220V/3A, DC 30V/5A). When choosing the dimension H (48*48*110mm), the relay capacity is AC 220V/0.6A, DC 30V/0.6A.
Additional power supply *P0: No power supply
P1: DC 24V, <30mA
Note: Additional power supply can provide DC power supply for other devices such as sensors.
Meter power supply *A: AC 100-240V, 50/60Hz
D: DC 20-29V
Power dissipation≤5W
Temperature drift0.2%FS/year
Shell materialABS
Isolation methodIsolation between input, output and power supply
Environment temperatureTemperature0~50℃ (32~122℉), humidity≤85%RH (no condensation)

Input signal selection chart:

NumberSignalParameter codeRangeNumberSignalParameter codeRange
0B typeT--B400~1800℃170-500ΩR0.5KFull range
1S typeT--S0~1600℃180-350Ω0350Full range
2K typeT--K0~1300℃1930-350Ω3350Full range
3E typeT--E0~1000℃200-20mV20MVFull range
4T typeT--T-200.0~+400.0℃210-40mV40MVFull range
5J typeT--J0~1200℃220-100mV100MFull range
6R typeT--R0~1600℃250-20mA20MAFull range
7N tyepT--N0~1300℃260-10mA10MAFull range
8F2T-F2700~2000℃274-20mA4-20Full range
9Wre3-25T-L30~2300℃280-5V0-5VFull range
10Wre5-26T-L50~2300℃291-5V1-5VFull range
11Cu50Cu50-50.0~+150.0℃310-10V10VFull range
12Cu53Cu53-50.0~+150.0℃32(0-10mA)^0.510MA.Full range
13Cu100C100-50.0~+150.0℃33(4-20mA)^0.520MA.Full range
14Pt100P100-200.0~+650℃34(0-5V)^0.50-5V.Full range
15BA1BA1-200.0~+600℃35(1-5V)^0.51-5V.Full range
16BA2BA2-200.0~+600℃----

Wiring diagram:
1. The wiring for dimension A/B/C/D/E
Wiring diagram for double 4 digit LED sensor meter dimension A/B/C/D/E
2. The wiring for dimension F
Wiring diagram for double 4 digit LED display controller dimension F
3. The wiring for dimension H
Wiring diagram for double 4 digit LED panel meter dimension H

In this video, ATO will show you how to set the basic parameters of digital panel meter, and how to connect a digital panel meter and a displacement sensor to form a simple displacement measuring system.

Temperature Controller Wiring and Settings

In this video, ATO will show you how to connect a temperature controller with a thermocouple or RTD sensor, and how to set the basic parameters of the temperature controller.

Load Cell Controller Setup and Calibration

In this video, we select an S-type load cell and a 2kg standard weight to complete the setup and calibration. Finally, ATO also shows you how to set the tare value and measure the tare weight.

Product reviews
Works as advertised
5
Bryan
Avatar
10/30/2022 9:41 PM
Excellent compact device! The Digital panel meter is easy to set up and install. So far, it has been used without problems and the display is very bright.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Digital panel meter has double 4 digit LED for PV and SV display. Digital display controller can be used for various sensors and transmitters, such as temperature sensor, pressure sensor, flow sensor, level sensor, displacement sensor, AC/DC current sensor, transmitter with 4-20mA/0-5V output, etc.

Specification:

BasicsModelATO-DPM-USD4D-1100
Dimension (W*H*L) *A: 160*80*110mm horizontal, hole size 152*76mm
B: 80*160*110mm vertical, hole size 76*152mm
C: 96*96*110mm, 92*92mm
D: 96*48*110mm horizontal, hole size 92*45mm
E: 48*96*110mm vertical, hole size 45*92mm
F: 72*72*110mm, hole size 68*68mm
H: 48*48*110mm, hole size 45*45mm
Shipping weight2 kg
Technical parametersDisplay range-1999~1999
Measurement accuracy0.3%FS
Display methodOne channel double 4 digit LED display (PV and SV)
Input signal *Thermocouple, RTD, linear resistance, presssure sensor, level sensor, current sensor, voltage sensor, analog signal, etc. (See details in the selection chart.)
Output signal *A0: No output
A1: 4-20mA (RL≤600Ω)
A2: 1-5V (RL≥250KΩ)
A3: 0-10mA (RL≤1.2KΩ)
A4: 0-5V (RL≥250KΩ)
A5: 0-20mA (RL≤600Ω)
A6: 0-10V (RL≥4KΩ)
T: RS485/232 (Modbus)
Alarm mode*R0: No alarm output
R1: 1 alarm relay
R2: 2 alarm relays
Note: 1 alarm relay includes: NO (AC 220V/3A, DC 30V/5A), 2 alarm relays include: NO+NO (AC 220V/3A, DC 30V/5A). When choosing the dimension H (48*48*110mm), the relay capacity is AC 220V/0.6A, DC 30V/0.6A.
Additional power supply *P0: No power supply
P1: DC 24V, <30mA
Note: Additional power supply can provide DC power supply for other devices such as sensors.
Meter power supply *A: AC 100-240V, 50/60Hz
D: DC 20-29V
Power dissipation≤5W
Temperature drift0.2%FS/year
Shell materialABS
Isolation methodIsolation between input, output and power supply
Environment temperatureTemperature0~50℃ (32~122℉), humidity≤85%RH (no condensation)

Input signal selection chart:

NumberSignalParameter codeRangeNumberSignalParameter codeRange
0B typeT--B400~1800℃170-500ΩR0.5KFull range
1S typeT--S0~1600℃180-350Ω0350Full range
2K typeT--K0~1300℃1930-350Ω3350Full range
3E typeT--E0~1000℃200-20mV20MVFull range
4T typeT--T-200.0~+400.0℃210-40mV40MVFull range
5J typeT--J0~1200℃220-100mV100MFull range
6R typeT--R0~1600℃250-20mA20MAFull range
7N tyepT--N0~1300℃260-10mA10MAFull range
8F2T-F2700~2000℃274-20mA4-20Full range
9Wre3-25T-L30~2300℃280-5V0-5VFull range
10Wre5-26T-L50~2300℃291-5V1-5VFull range
11Cu50Cu50-50.0~+150.0℃310-10V10VFull range
12Cu53Cu53-50.0~+150.0℃32(0-10mA)^0.510MA.Full range
13Cu100C100-50.0~+150.0℃33(4-20mA)^0.520MA.Full range
14Pt100P100-200.0~+650℃34(0-5V)^0.50-5V.Full range
15BA1BA1-200.0~+600℃35(1-5V)^0.51-5V.Full range
16BA2BA2-200.0~+600℃----

Wiring diagram:
1. The wiring for dimension A/B/C/D/E
Wiring diagram for double 4 digit LED sensor meter dimension A/B/C/D/E
2. The wiring for dimension F
Wiring diagram for double 4 digit LED display controller dimension F
3. The wiring for dimension H
Wiring diagram for double 4 digit LED panel meter dimension H

Product reviews
Works as advertised
5
Bryan
Avatar
10/30/2022 9:41 PM
Excellent compact device! The Digital panel meter is easy to set up and install. So far, it has been used without problems and the display is very bright.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

AC Current Sensor, AC 200A/400A/600A/800A

ATO-CUS-AC800
$88.25
AC current sensor adopts electromagnetic isolation principle, small size, light weight, low price, fast response, high accuracy, good stability, 35mm/45mm/55mm hole diameter, and screws fixed installation. AC current sensor is widely used for AC current measurement of various occasions, especially for sine-wave ac current with power frequency 50Hz.

Tension/Compression Load Cell, Low Profile, 500kg/30 ton to 100 ton

ATO-LC-P02
$145.28
Low profile load cell also known as pancake load cell, has flat design, high strength and good symmetry. Tension and compression load cell can be applied for platform scale, truck scale, rail weighbridge and material level measurement and control in warehouse, with good anti-eccentric load performance, low height, all sealed structure and complete specifications.

High Temperature Pressure Sensor for Steam/Fuel Oil

ATO-PRES-P300G
$153.97
High-temperature pressure sensor covers -0.1 to 100 MPa and supports 4–20mA, 0–20mA, voltage and RS485 outputs. Designed for steam, fuel oil and other high-temperature liquids, it supports medium temperatures up to 300°C and uses cooling fins for thermal isolation.

RTD Sensor Probe, Pt100, 3 Wire

ATO-RTD-PB3W
$108.38
RTD sensor probe adopts high-quality temperature chip to ensure long-term stability and high accuracy. High-quality PTFE shielded wires can effectively shield interference. The 3 wire Pt100 temperature sensor probe measurement range is -50~+200℃ (-58~+392℉). It can be used for pipeline, container, solid surface and end face temperature measurement.

Reaction Torque Sensor, Dual Flange, 20 Nm/100 Nm/5000 Nm to 10000 Nm

ATO-TQS-S01
$193.92
Torque sensor is a strain gauge sensor for static torque measurement. Static torque sensor has double-flange, a 5 pin male plug and no mounting base so it can be easy to install. Reaction torque sensors have a capacity range from 20 Nm/300 Nm/2000 Nm to 10000 Nm and can measure both forward and reverse torque.