Digital counter has 6 digit display, frequency/rev/linear speed measuring function, DC 12V/24V external power supply.
Features:
- Various parameter settings, simple operation.
- Input: Various waveform pulses (square wave, triangle wave), proximity sensor, photoelectric sensor, voltage signal, contact switch, encoder, etc.
- Digital counter can also be used to measure the power frequency (AC 0-600V), measurement range: 0.01Hz-100KHz, resolution: 0.01Hz.
- 6 digit display, decimal point automatic conversion.
- Input/output signals photoelectric isolated, anti-interference ability.
- Digital output: Up to 3 alarms, high value, low value, high and low value alarm modes are optional, analog output: 4-20mA or 0-10V transmission output, measuring range setting arbitrarily.
- Standard RS232 or RS485 MODBUS RTU communication, can be directly connected with computers, PLC or other equipments.
Specification:
| Mode | ATO-DIGC-FA6 |
| Weight | 350g |
| Accuracy | 0.1%±2 digit |
| Power supply | AC 220V/110V±15%, AC 90-260V, DC 24V±10%, power dissipation≤5VA |
| Input signal | Pulse signal, square wave, sine wave, 5V≤H≤30V, 0≤L≤2V, rising edge trigger, frequency: 0.01~10KHz, 1Hz-100KHz |
| Display counting range | -199999~999999 |
| Input impedance | ≥10KΩ |
| Transmission output | 4-20mA, 0-10V, etc. (range can be set) |
| Insulation resistance | ≥100MΩ (between DC 500V power terminal and external terminal) |
| Dielectric strength | AC 1500V 1min (between power terminal and external terminal) |
| Environment | Ambient temperature: 0~50°C, relative humidity: 35~85%RH |
| External power supply | DC 12V±5%, 50mA max / DC 24V±5%, 30mA max |
| Protection class | IP65 |
Selection table:
| Dimension (length*height*depth) | Power supply | AL1 | AL2 | Communication interface | External power supply |
| 7: 72*72*80mm with hole size 67.5*67.5mm; 8: 96*48*80mm with hole size 92*45mm | V0: AC 90-260V; VE: AC/DC 12-30V, or DC 24V | N: No output; R: Relay; S: SSR/LOGIC | N: No output; R: Relay; S: SSR/LOGIC | C0: No communication; C2: RS232; C4: RS485 | A: DC 12V/30mA; B: DC 24V/30mA; C: DC 5V |
Wiring diagram:
Tips: Error of digital counter
- Quantization error
In the digital measurement of frequency, the measured quantity is not exactly an integral multiple of the standard unit. So there is a part of the time not counted in the quantization process cause the error. Besides, the gate opening and closing time are out of sync (random) with measured signals, which will cause plus or minus error of digital counter. - Trigger error
Under the influences of interference signal, the gating pulse let the triggering advanced or lagged, and then trigger error is caused. - Standard frequency error
Under the influences of the external environment or its own structural performance and other factors, the standard frequency (such as the crystal oscillator) adopted by digital counter will produce drift, and then standard frequency error is introduced.
Product reviews
Good 6 digit digital counter
Jbindc
5/6/2021 7:34 PM
I am interested in your 6 digit digital counter. However I need to know if it comes with a sensor for input. It is intended to couple it with wheel to count predetermined revolutions and automatically stop the revolving wheel when the value is reached.
Was this review helpful? (0/0)
I am looking for a 6 digit digital counter
Bowden
12/16/2021 1:32 AM
I am looking for information on how I would use your photoelectric sensor and digital counter to stop a vfd when it hits a predetermined count. Is there a support forum for this scenario?
Was this review helpful? (0/0)
Digital counter work with turbine flow sensor
roze
7/25/2023 2:56 AM
Please let me know if the digital counter can be used with an NPN turbine flow sensor with a pulse rate/K factor of 119 pulse/liter -
8.40 ml/pulse.
8.40 ml/pulse.
Was this review helpful? (0/0)
Widely applicable
Citrali
1/15/2025 2:12 AM
It has a wide measurement range and can accurately measure signals from low to high frequencies, as well as different speeds and speeds. This is very practical for my job because I often need to measure the operating parameters of various mechanical equipment.
Was this review helpful? (0/0)
Only registered users can write reviews