This SKU ATO-VOS-BDC1000S is out of stock.
We recommend you another bidirectional DC voltage sensor ATO-VOS-BDC1000, which has measuring range from ±50mV, ±50V, ±200V, ±500V to ±1000V and power supply DC 12V/15V/24V.
DC voltage transducer has measuring range of DC ±10mV, ±50mV, ±100V, ±200V, ±500V to ±1000V.
Specification:
| Model | ATO-WBV351M05 | |||
| Shipping weight | 1kg | |||
| Measuring range of input voltage * | DC ±10mV ~ ±1000V | |||
| Short-time overload | 2 times of nominal input voltage, 1s in duration, interval time 10s, repeat 10 times | |||
| Linear measurement range | 0% ~ 120% measuring range | |||
| Input impedance | When Ux>1V, Ri=Ux*10kΩ/V; when Ux≤1V, Ri≥1MΩ | |||
| Output signal * | DC ±5V, ±10V | |||
| Power supply | DC 9-36V | |||
| Accuracy | 0.1%F.S. | |||
| Load capacity | 10mA | |||
| Response time | ≤20ms | |||
| Temperature drift | 50*10-6/℃ | |||
| Static power consumption | 0.32W | |||
| Isolation features | Isolation between input, output and power supply | |||
| Isolation voltage | DC 2.5kV, 1 min | |||
| Work temperature | -25~+70℃ | |||
| Storage temperature | -40~+85℃ | |||
| Protection features | Surge (inrush) immunity: IEC61000-4-5 Electrostatic discharge immunity: IEC61000-4-2 Radio frequency electromagnetic field radiation immunity: IEC61000-4-3 Electrical fast transient burst immunity: IEC61000-4-4 Conducted immunity of radio frequency electromagnetic field: IEC61000-4-6 | |||
| Mean time between failures | >50000h | |||
| Housing material | PC + Fire-retardant ABS | |||
| Wiring | Terminal connection | |||
| Installation | DIN rail (NS35/7.5, NS35/15, EN50022), or screw (M3) fixation | |||
DC voltage transducer for bidirectional voltage 10mV to 1000V dimensional drawing (unit: mm):
DC voltage transducer 10mV to 1000V wiring diagram:
Details

Product reviews
Reliable DC voltage transducer
Johnny
4/15/2026 7:39 PM
I installed this DC voltage transducer in my solar energy monitoring system to track bidirectional voltage flow. The accuracy is impressive, and the output signal remains stable even with fluctuations. It responds quickly and integrates easily with my setup. Overall, it feels reliable.
Was this review helpful? (0/0)
Only registered users can write reviews