This SKU ATO-VOS-DC1000S is out of stock.
We recommend you another isolated DC voltage sensor ATO-VOS-DC1000, which has measuring range from DC 10mV, 50mV, 75mV, 5V, 75V, 150V, 300V, 500V to 1000V and power supply DC 12V/24V.
DC voltage sensor has measuring range of 10mV/50mV/75mV/5V/50V/150V/200V/300V/400V/500V/750V to 1000V.
Specification:
| Model | ATO-WBV344M05 | |||
| Shipping weight | 1kg | |||
| Measuring range of input voltage * | DC 0-10mV ~ 0-1000V | |||
| Short-time overload | 2 times of nominal input voltage, 1s in duration, interval time 10s, repeat 10 times | |||
| Linear measurement range | 0% ~ 120% measuring range | |||
| Input impedance | When Ux>1V, Ri=Ux*10kΩ/V; when Ux≤1V, Ri≥1MΩ | |||
| Output signal * | DC 0-20mA, 4-20mA | |||
| Power supply | DC 9-36V | |||
| Accuracy | 0.2%F.S. | |||
| Load capacity | 300Ω | |||
| Response time | ≤20ms | |||
| Temperature drift | 50*10-6/℃ | |||
| Static power consumption | 0.32W | |||
| Isolation features | Isolation between input, output and power supply | |||
| Isolation voltage | DC 2.5kV, 1 min | |||
| Work temperature | -25~+70℃ | |||
| Storage temperature | -40~+85℃ | |||
| Protection features | Surge (inrush) immunity: IEC61000-4-5 Electrostatic discharge immunity: IEC61000-4-2 Radio frequency electromagnetic field radiation immunity: IEC61000-4-3 Electrical fast transient burst immunity: IEC61000-4-4 Conducted immunity of radio frequency electromagnetic field: IEC61000-4-6 | |||
| Mean time between failures | >50000h | |||
| Housing material | PC + Fire-retardant ABS | |||
| Wiring | Terminal connection | |||
| Installation | DIN rail (NS35/7.5, NS35/15, EN50022), or screw (M3) fixation | |||
DC voltage transducer 10mV to 1000V dimensional drawing (unit: mm):
DC voltage transducer 10mV to 1000V wiring diagram:
Details