Current Transformer, 200/5A, 400/5A, 600/5A to 1000/5A

$119.67
Low price current transformer can select ratio 200/5A, 300/5A, 600/5A and 1000/5A. rated frequency 50Hz or 60Hz, small size and light weight, manufacturer direct sale.
SKU: ATO-CT-60I
*
*
Free Shipping
Delivery date: 6-12 days

Current transformer is used to convert large currents in the AC circuit into a small proportion of current for measurement and relay protection. Current ratio 250:5A, 400:5A, 750:5A, 800:5A to1000:5A, cheap price, good quality and free shipping.

Note: The installation method of current transformer can be fixed by busbar and fixed by the bottom plate, suitable for installation in any direction. The primary conductor can be busbar or cable.

Specification:

ModelATO-CT-60I
Weight1kg
Current Ratio (A)VA Secondary load/ Burden (VA)Cross-core Turn Number
0.20.5S0.2S
250-450/52.52.52.51
500-800/55551
1000/5/551
1200-1250/5/15101
Rated Frequency50/60Hz
Rated Test Voltage3kV AC (1min)
Rated Short-Time Thermal Current (ith)60 in
Rated Dynamic Current (idyn)2.5 lth
Rated Voltage (Um)0.66 kV AC
Continuous Overload (ld)1.2 in
Operating Temperature-10℃~50℃
Housing Self-Extinguishing ClassVO
Safety FactorFS 5
Secondary Current5A/ 1A
Bus Specification (mm)/Number1

Dimension

Current transformer dimension

ModelDimensionsPerforation sizeInstallation size
WHDaeφMN
ATO-CT-30I6278453211224057.5
ATO-CT-3030I8510250321128/57.5
ATO-CT-40I7595454211314057.5
ATO-CT-60I1021304561.521454257.5
ATO-CT-60II102125453133/4257.5
ATO-CT-80I118140458211526057.5
ATO-CT-100II1451254510335/8057.5


Tips:
Current Transformer Troubleshooting

  • There should be no open circuit on the secondary side of the current transformer in operation. Once the open circuit occurs on the secondary side, high temperature caused by excessive iron loss may burn out the current transformer or enhance the voltage of secondary winding, thus breaking down the insulation and leading to the danger of high voltage electric shock. Therefore, when replacing a meter such as an ammeter, active power meter and reactive power meter, please ensure the current circuit in short circuit before operation. If the current transformer makes a buzz sound, please check if the internal core is loose, fasten the core bolt.
  • Shell of the current transformer’s secondary side shall be grounded reliably.
  • When the insulation resistance of the current transformer’s secondary side coil is lower than 10~20M ohms, drying process is required to recover the insulation before use it again.
  • When the current transformer gets faults, safety operation of the primary system circuits will be affected, please report promptly to the higher authorities and heads of departments concerned to cut off the fault current transformer timely, then treatment it. As for the open circuit of secondary winding, treatments shall be implemented according to actual conditions. After necessary safety precautions are made according to relevant regulations, the current transformer can be put in use again.
Product reviews
High cost effective current transformers
5
Martines
Avatar
11/8/2018 8:07 PM
It's a cheap price, and I bought two current transformers, one current ratio 300/ 5A, and a current ratio 400/5A.
They worked very well, and accurately, the quality is in my demand.
Was this review helpful? Yes No (0/0)
Works fine
5
Stults
Avatar
6/29/2022 3:12 AM
These current transformers are quick and simple to assemble. You just need a little soldering experience and it goes right together. I am using it to measure a couple motors and there is no problems. It seems to work really well.
Was this review helpful? Yes No (0/0)
Looking for current transformers
5
Jepas
Avatar
6/3/2026 12:44 AM
Our company is looking for current transformers and requires some customization options to meet specific customer needs. Our installation project only requires split-type current transformers.
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our ATO-CT-60I model to see if it meets your requirements.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Current transformer is used to convert large currents in the AC circuit into a small proportion of current for measurement and relay protection. Current ratio 250:5A, 400:5A, 750:5A, 800:5A to1000:5A, cheap price, good quality and free shipping.

Note: The installation method of current transformer can be fixed by busbar and fixed by the bottom plate, suitable for installation in any direction. The primary conductor can be busbar or cable.

Specification:

ModelATO-CT-60I
Weight1kg
Current Ratio (A)VA Secondary load/ Burden (VA)Cross-core Turn Number
0.20.5S0.2S
250-450/52.52.52.51
500-800/55551
1000/5/551
1200-1250/5/15101
Rated Frequency50/60Hz
Rated Test Voltage3kV AC (1min)
Rated Short-Time Thermal Current (ith)60 in
Rated Dynamic Current (idyn)2.5 lth
Rated Voltage (Um)0.66 kV AC
Continuous Overload (ld)1.2 in
Operating Temperature-10℃~50℃
Housing Self-Extinguishing ClassVO
Safety FactorFS 5
Secondary Current5A/ 1A
Bus Specification (mm)/Number1

Dimension

Current transformer dimension

ModelDimensionsPerforation sizeInstallation size
WHDaeφMN
ATO-CT-30I6278453211224057.5
ATO-CT-3030I8510250321128/57.5
ATO-CT-40I7595454211314057.5
ATO-CT-60I1021304561.521454257.5
ATO-CT-60II102125453133/4257.5
ATO-CT-80I118140458211526057.5
ATO-CT-100II1451254510335/8057.5


Tips:
Current Transformer Troubleshooting

  • There should be no open circuit on the secondary side of the current transformer in operation. Once the open circuit occurs on the secondary side, high temperature caused by excessive iron loss may burn out the current transformer or enhance the voltage of secondary winding, thus breaking down the insulation and leading to the danger of high voltage electric shock. Therefore, when replacing a meter such as an ammeter, active power meter and reactive power meter, please ensure the current circuit in short circuit before operation. If the current transformer makes a buzz sound, please check if the internal core is loose, fasten the core bolt.
  • Shell of the current transformer’s secondary side shall be grounded reliably.
  • When the insulation resistance of the current transformer’s secondary side coil is lower than 10~20M ohms, drying process is required to recover the insulation before use it again.
  • When the current transformer gets faults, safety operation of the primary system circuits will be affected, please report promptly to the higher authorities and heads of departments concerned to cut off the fault current transformer timely, then treatment it. As for the open circuit of secondary winding, treatments shall be implemented according to actual conditions. After necessary safety precautions are made according to relevant regulations, the current transformer can be put in use again.
Product reviews
High cost effective current transformers
5
Martines
Avatar
11/8/2018 8:07 PM
It's a cheap price, and I bought two current transformers, one current ratio 300/ 5A, and a current ratio 400/5A.
They worked very well, and accurately, the quality is in my demand.
Was this review helpful? Yes No (0/0)
Works fine
5
Stults
Avatar
6/29/2022 3:12 AM
These current transformers are quick and simple to assemble. You just need a little soldering experience and it goes right together. I am using it to measure a couple motors and there is no problems. It seems to work really well.
Was this review helpful? Yes No (0/0)
Looking for current transformers
5
Jepas
Avatar
6/3/2026 12:44 AM
Our company is looking for current transformers and requires some customization options to meet specific customer needs. Our installation project only requires split-type current transformers.
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our ATO-CT-60I model to see if it meets your requirements.
Only registered users can write reviews