Cheap price AC current transformer with light weight, low price, fast response, high accuracy and good stability. The current ratio 10:5A, 25:5A, 30:5A and 75:5A are optional.
Note: The installation method of current transformer can be fixed by busbar and fixed by the bottom plate, suitable for installation in any direction. The primary conductor can be busbar or cable.
Specification:
| Model | ATO-CT-30I | |||
| Weight | 1kg | |||
| Current Ratio (A) | VA Secondary load/ Burden (VA) | Cross-core Turn Number | ||
| 0.2 | 0.5S | 0.2S | ||
| 10/5 | 2.5 | 1.5 | 1.5 | 15 |
| 15/5 | 2.5 | 1.5 | 1.5 | 10 |
| 20/5 | 2.5 | 1.5 | 1.5 | 8 |
| 25/5 | 2.5 | 1.5 | 1.5 | 6 |
| 30/5 | 2.5 | 1.5 | 1.5 | 5 |
| 40/5 | 2.5 | 1.5 | 1.5 | 4 |
| 50/5 | 2.5 | 1.5 | 1.5 | 3 |
| 75/5 | 2.5 | 1.5 | 1.5 | 2 |
| Rated Frequency | 50/60Hz | |||
| Rated Test Voltage | 3kV AC (1min) | |||
| Rated Short-Time Thermal Current (ith) | 60 in | |||
| Rated Dynamic Current (idyn) | 2.5 lth | |||
| Rated Voltage (Um) | 0.66 kV AC | |||
| Continuous Overload (ld) | 1.2 in | |||
| Operating Temperature | -10℃~50℃ | |||
| Housing Self-Extinguishing Class | VO | |||
| Safety Factor | FS 5 | |||
| Secondary Current | 5A/ 1A | |||
| Bus Specification (mm)/Number | / | |||
Dimension (unit: mm)

| Model | Dimensions | Perforation size | Installation size | |||||
| W | H | D | a | e | φ | M | N | |
| ATO-CT-30I | 62 | 78 | 45 | 32 | 11 | 22 | 40 | 57.5 |
| ATO-CT-3030I | 85 | 102 | 50 | 32 | 11 | 28 | / | 57.5 |
| ATO-CT-40I | 75 | 95 | 45 | 42 | 11 | 31 | 40 | 57.5 |
| ATO-CT-60I | 102 | 130 | 45 | 61.5 | 21 | 45 | 42 | 57.5 |
| ATO-CT-60II | 102 | 125 | 45 | 31 | 33 | / | 42 | 57.5 |
| ATO-CT-80I | 118 | 140 | 45 | 82 | 11 | 52 | 60 | 57.5 |
| ATO-CT-100II | 145 | 125 | 45 | 103 | 35 | / | 80 | 57.5 |
Tips: How to Prevent Current Transformer Burning up?
- Add a watchdog breaker and avoid the power failure of whole feeder line caused by faults on branches, particularly, ensure that the branch breaker can trip correctly in case of single-phase grounding at the user side.
- Connect the metering current transformer downstream the breaker, so as to guarantee that the breaker and lightning arrester operate correctly to remove faults when the transformer breaks down.
- Strengthen the flashing test for user’s high voltage metering current transformer and lightning arrester (it shall not be more than 4 years according to regulations), find out the aging degree of current transformer and lightning arrester insulation as early as possible, replace timely to avoid power failure caused by burning out of metering current transformer.
- Clean the user primary device regularly to reduce the occurrence of flashover, avoid insulation reduction.
Product reviews
Good frequency response
Thomas
9/27/2018 12:49 AM
I am using to monitor a well pump current draw. Devices installed easily and perform well. Good frequency response aided in identifying the various loads. I am very satisfied with this current transformer.
Was this review helpful? (1/0)
Cool CT
Karl
2/4/2020 12:05 AM
I'm sure this is a cool CT, the price is very cheap, buy a few'll always get, and measure my generator power, ATO current transformer did a great job!
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
Current Transformer, 30/5A, 75/5A, 100/5A to 400/5A
ATO-CT-3030I
$116.98
Low cost CT transformer rated frequency 50Hz and 60Hz are optional, current ratio can be 30/5A, 75/5A, 100/5A, 200/5A and 400/5A, accuracy classes can be selected. AC current transformer with high accuracy, fast response and light weight.