Calcium Ion Selective Electrode

$141.29
Economical price calcium ion selective electrode (Ca2+ ISE) is a specialized sensor used to measure the concentration of calcium ions in a solution. Calcium ISE is widely used in clinical laboratories for monitoring blood calcium levels, environmental analysis for assessing calcium concentrations in water samples, and industrial processes where precise control of calcium levels is crucial.
SKU: ATO-ISE-CALCIUM
Free Shipping
Delivery date: 6-12 days

Calcium ion selective electrode (Ca2+ ISE) is a specialized electrochemical sensor designed to measure the concentration of calcium ions in a solution. Its selective nature and high sensitivity make them valuable tools for quantitative analysis, offering a reliable and efficient method for calcium ion detection in diverse applications.

Specification

ModelATO-PCa-1-01
Electrode TypeSingle Electrode
IonCalcium Ion (Ca2+)
Standard SolutionCaCl2 Solution
Measuring Range1 x 10-5~10-1mol/L
0.4mg/L~4g/L
Ionic Strength Adjuster (Powder)Small Amount of KCl
High-end Ionic Strength RegulatorIonic Strength Regulator Type Ⅱ
Sensitive Film MaterialPVC Film
Shell MaterialPlexiglass
Working Temperature5℃~60℃
InterfaceBNC (Q9)
Dimensionφ12*120mm
Recommend Reference ElectrodeATO-232-01


Dimension

Calcium ion selective electrode ISE dimension

Detail

Calcium ion selective electrode ISE detail

Application

Calcium ion selective electrode ISE application

Tips: What are the applications of calcium ion selective electrodes?

Calcium ion-selective electrodes (ISEs) find diverse applications in analytical chemistry and various industries due to their ability to selectively measure the concentration of calcium ions in solution. In medical diagnostics, these electrodes are employed to assess calcium levels in blood serum, aiding in the diagnosis of disorders such as hyperparathyroidism and hypocalcemia. In environmental monitoring, calcium ISEs contribute to assessing water quality by measuring calcium concentrations in bodies of water, essential for understanding ecological health. Additionally, these electrodes play a crucial role in the food and beverage industry, ensuring quality control by monitoring calcium content in dairy products and beverages. Moreover, researchers use calcium ISEs in pharmaceutical development to analyze calcium ion interactions in drug formulations. The versatility and precision of calcium ISEs make them invaluable tools across scientific, industrial, and medical domains, facilitating accurate analyses and contributing to advancements in various fields.

In this video, ATO will show you top ten most used sensors (sensing technologies).

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Calcium ion selective electrode (Ca2+ ISE) is a specialized electrochemical sensor designed to measure the concentration of calcium ions in a solution. Its selective nature and high sensitivity make them valuable tools for quantitative analysis, offering a reliable and efficient method for calcium ion detection in diverse applications.

Specification

ModelATO-PCa-1-01
Electrode TypeSingle Electrode
IonCalcium Ion (Ca2+)
Standard SolutionCaCl2 Solution
Measuring Range1 x 10-5~10-1mol/L
0.4mg/L~4g/L
Ionic Strength Adjuster (Powder)Small Amount of KCl
High-end Ionic Strength RegulatorIonic Strength Regulator Type Ⅱ
Sensitive Film MaterialPVC Film
Shell MaterialPlexiglass
Working Temperature5℃~60℃
InterfaceBNC (Q9)
Dimensionφ12*120mm
Recommend Reference ElectrodeATO-232-01


Dimension

Calcium ion selective electrode ISE dimension

Detail

Calcium ion selective electrode ISE detail

Application

Calcium ion selective electrode ISE application

Tips: What are the applications of calcium ion selective electrodes?

Calcium ion-selective electrodes (ISEs) find diverse applications in analytical chemistry and various industries due to their ability to selectively measure the concentration of calcium ions in solution. In medical diagnostics, these electrodes are employed to assess calcium levels in blood serum, aiding in the diagnosis of disorders such as hyperparathyroidism and hypocalcemia. In environmental monitoring, calcium ISEs contribute to assessing water quality by measuring calcium concentrations in bodies of water, essential for understanding ecological health. Additionally, these electrodes play a crucial role in the food and beverage industry, ensuring quality control by monitoring calcium content in dairy products and beverages. Moreover, researchers use calcium ISEs in pharmaceutical development to analyze calcium ion interactions in drug formulations. The versatility and precision of calcium ISEs make them invaluable tools across scientific, industrial, and medical domains, facilitating accurate analyses and contributing to advancements in various fields.

Only registered users can write reviews
Customers who bought this item also bought

Chloride Ion Selective Electrode

ATO-ISE-CHLORIDE
$141.29
ATO chloride ion-selective electrode (ISE) is a sensor used with a reference electrode and ion meter in analytical chemistry to measure the concentration of chloride ions (Cl-) in a solution, measuring range from 5x10-5~10-1mol/L. The low price specific electrode consists of a membrane selective to chloride ions, made of silver chloride, surrounded by a reference solution containing a fixed concentration of chloride ions.

Potassium Ion Selective Electrode

ATO-ISE-POTASSIUM
$185.79
Potassium ion selective electrode (ISE) for sale. This economical price specific electrode needs to be used in conjunction with a reference electrode and an ion meter. Potassium ISE is a sensor designed to measure the concentration of potassium ions in a solution. It is widely used in clinical chemistry, environmental monitoring, and industrial processes, providing a rapid and accurate method for quantifying potassium levels in liquid samples.

Sodium Ion Selective Electrode

ATO-ISE-SODIUM
$214.29
Economical price sodium ion selective electrode (ISE) for sale online. It is a specialized electrochemical sensor designed to measure the concentration of sodium ions in a solution. Specific electrode needs to be used in conjunction with a reference electrode and composite ISE consists of a reference electrode and a sensing electrode.