Argon Gas Flow Meter, 0~2/20/100L/min

$455.63
The argon flow meter covering the range of 0~2L/20/100L/min is available for sale, with internal alarm function and RS485/1~5V/4~20mA output options. Equipped with LCD display for reading display, the detection status is clear at a glance.
SKU: ATO-FLOW-AMS
*
*
*
Free Shipping
Delivery date: 6-12 days

High-performance argon flow meter in hot sale. Integrated mass flow and temperature measurement, standard RS485 Modbus RTU communication, optional 4-20mA/1-5V signal output, multiple ranges from 0-2/20/100L/min, has been widely used in university research, fire fighting, environmental monitoring, tobacco, intelligent agriculture, food, medicine and other industries.

Specification

ModelATO-AMS1000A02ATO-AMS1000A01ATO-AMS1000A03
Flow Range0~2L/min0~20L/min1~100L/min
Signal OutputDefault RS485+4-20mA/RS485+1-5V (optional)
Nominal DiameterG1/4
Communication Method & ProtocolRS485, MODBUS-RTU
Accuracy±2%RD/±4%RD (optional)
Repeatability±1%F.S.
Response Time50ms
Power SupplyExternal power supply 9 to 24V DC
Display ModeLCD display
Maximum Working Pressure0.8MPa
Standard Calibration GasAir (25℃, 1 standard atmospheric pressure)
Working Temperature-10°C~+60°C
Power Consumption<0.85W
Housing MaterialPC
Duct MaterialAluminum
Net WeightApprox. 330g


Flow Meter Flow Range

ModelFlow RangeAccuracyOutput SignalInterface
ATO-AMS1000A020.02~2L/min±4%RD (0.02≦x≦0.5L/min) /±2%RD (0.5<x≦2L/min)RS485, 4-20mA, 1-5VG1/4
ATO-AMS1000A010.2~20L/min±4%RD (0.2≦x≦5L/min) /±2%RD (5<x≦20L/min)RS485, 4-20mA, 1-5VG1/4
ATO-AMS1000A031~100L/min±4%RD (1≦x≦25L/min) /±2%RD (25<x≦100L/min)RS485, 4-20mA, 1-5VG1/4


Dimension (unit: mm)

Argon gas flow meter dimension

Structure

Argon gas flow meter structure

Interface Definition

Argon gas flow meter interface definitions

PinLead Wire ColorDefinition
1OrangeExternal output 1
2BrownAnalog output
3GreenRS485B
4YellowRS485A
5RedPower supply cable
6BlackGND
7BlueGND
8PurpleGND
9GrayExternal output 2
/Transparent Heat Shrink SleeveShielded cable


Piping Methods

Argon gas flow meter piping method

For the air ducts connected to the inlet and outlet ports of the AMS1000 series, please reserve a straight portion of the air duct according to the inlet straight length ≥12.5cm and the outlet straight length ≥6.25, otherwise the accuracy may be shifted by 3% F.S. or more.

The sensor duct of the argon flow meter is recommended to be installed parallel or perpendicular to the horizontal plane. When the sensor is mounted parallel to the horizontal plane, the sensor interface must be above the sensor duct and parallel to the horizontal plane.

Application

Argon gas flow meter application

Tips: Argon gas flow meter common problems and solutions

Common ProblemsSolution
Inaccurate flow rate, too big or too small or even no flow.1. compliance with specification takeover requirements.
2. whether the incoming gas meets the requirements. 3. whether the gas pressure meets the minimum 0.1Mpa driving standard.
3. whether the air pressure of the gas supply reaches the minimum 0.1Mpa driving standard. 4. whether the installation environment is free from vibration or interference.
4. the installation environment is free of vibration or interference.
Front and rear piping requirementsThe inlet of the flow meter needs to be connected to a long straight pipe, refer to the specification for details of installation, and the installation environment should be free from vibration and electromagnetic interference.
Wide variation of values before and after the same pipeDue to the different placement, the pressure resistance is different, resulting in different flow rate readings.
What type of gas can the flow meter pass through?Gas flow meter through the gas can only be a single gas, mixed gases can not be detected, and the gas needs to be dry and clean, can not carry moisture and oil.
Product reviews
I have some questions
5
Cochin
Avatar
6/27/2025 12:48 AM
Is the argon flow meter accurate in measuring argon without recalibration? How to connect the flow meter to a computer for data logging?
Was this review helpful? Yes No (0/0)
ATO Responded
This flow meter supports output analog signals 0-10V or 4-20mA, with RS485 communication. If you want to log data on a PC, you need to configure the controller and software to read these signals yourself. We do not currently provide related software.
Relevant certificates
5
Patik
Avatar
7/3/2026 12:45 AM
Hello. I'm very interested in this product and would like to know if it comes with a calibration certificate or certificate of conformity. I plan to purchase the model with a flow range of 0-100 liters/minute.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, what gas medium will you be measuring? This unit can provide a factory-standard calibration report.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High-performance argon flow meter in hot sale. Integrated mass flow and temperature measurement, standard RS485 Modbus RTU communication, optional 4-20mA/1-5V signal output, multiple ranges from 0-2/20/100L/min, has been widely used in university research, fire fighting, environmental monitoring, tobacco, intelligent agriculture, food, medicine and other industries.

Specification

ModelATO-AMS1000A02ATO-AMS1000A01ATO-AMS1000A03
Flow Range0~2L/min0~20L/min1~100L/min
Signal OutputDefault RS485+4-20mA/RS485+1-5V (optional)
Nominal DiameterG1/4
Communication Method & ProtocolRS485, MODBUS-RTU
Accuracy±2%RD/±4%RD (optional)
Repeatability±1%F.S.
Response Time50ms
Power SupplyExternal power supply 9 to 24V DC
Display ModeLCD display
Maximum Working Pressure0.8MPa
Standard Calibration GasAir (25℃, 1 standard atmospheric pressure)
Working Temperature-10°C~+60°C
Power Consumption<0.85W
Housing MaterialPC
Duct MaterialAluminum
Net WeightApprox. 330g


Flow Meter Flow Range

ModelFlow RangeAccuracyOutput SignalInterface
ATO-AMS1000A020.02~2L/min±4%RD (0.02≦x≦0.5L/min) /±2%RD (0.5<x≦2L/min)RS485, 4-20mA, 1-5VG1/4
ATO-AMS1000A010.2~20L/min±4%RD (0.2≦x≦5L/min) /±2%RD (5<x≦20L/min)RS485, 4-20mA, 1-5VG1/4
ATO-AMS1000A031~100L/min±4%RD (1≦x≦25L/min) /±2%RD (25<x≦100L/min)RS485, 4-20mA, 1-5VG1/4


Dimension (unit: mm)

Argon gas flow meter dimension

Structure

Argon gas flow meter structure

Interface Definition

Argon gas flow meter interface definitions

PinLead Wire ColorDefinition
1OrangeExternal output 1
2BrownAnalog output
3GreenRS485B
4YellowRS485A
5RedPower supply cable
6BlackGND
7BlueGND
8PurpleGND
9GrayExternal output 2
/Transparent Heat Shrink SleeveShielded cable


Piping Methods

Argon gas flow meter piping method

For the air ducts connected to the inlet and outlet ports of the AMS1000 series, please reserve a straight portion of the air duct according to the inlet straight length ≥12.5cm and the outlet straight length ≥6.25, otherwise the accuracy may be shifted by 3% F.S. or more.

The sensor duct of the argon flow meter is recommended to be installed parallel or perpendicular to the horizontal plane. When the sensor is mounted parallel to the horizontal plane, the sensor interface must be above the sensor duct and parallel to the horizontal plane.

Application

Argon gas flow meter application

Tips: Argon gas flow meter common problems and solutions

Common ProblemsSolution
Inaccurate flow rate, too big or too small or even no flow.1. compliance with specification takeover requirements.
2. whether the incoming gas meets the requirements. 3. whether the gas pressure meets the minimum 0.1Mpa driving standard.
3. whether the air pressure of the gas supply reaches the minimum 0.1Mpa driving standard. 4. whether the installation environment is free from vibration or interference.
4. the installation environment is free of vibration or interference.
Front and rear piping requirementsThe inlet of the flow meter needs to be connected to a long straight pipe, refer to the specification for details of installation, and the installation environment should be free from vibration and electromagnetic interference.
Wide variation of values before and after the same pipeDue to the different placement, the pressure resistance is different, resulting in different flow rate readings.
What type of gas can the flow meter pass through?Gas flow meter through the gas can only be a single gas, mixed gases can not be detected, and the gas needs to be dry and clean, can not carry moisture and oil.
Product reviews
I have some questions
5
Cochin
Avatar
6/27/2025 12:48 AM
Is the argon flow meter accurate in measuring argon without recalibration? How to connect the flow meter to a computer for data logging?
Was this review helpful? Yes No (0/0)
ATO Responded
This flow meter supports output analog signals 0-10V or 4-20mA, with RS485 communication. If you want to log data on a PC, you need to configure the controller and software to read these signals yourself. We do not currently provide related software.
Relevant certificates
5
Patik
Avatar
7/3/2026 12:45 AM
Hello. I'm very interested in this product and would like to know if it comes with a calibration certificate or certificate of conformity. I plan to purchase the model with a flow range of 0-100 liters/minute.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, what gas medium will you be measuring? This unit can provide a factory-standard calibration report.
Only registered users can write reviews