80 Amps 4 Pole AC Contactor 24V/110V/220V Coil

$148.46
80 Amps 4 pole bypass AC contactors with compact structure and complete specifications. It has 4P (4NO) and 4P (2NO+2NC) contact form, 24V, 110V, 220V coil voltage for you to choose, direct sale from manufacturer.
SKU: ATO-ACCON-080
*
*
Free Shipping
Delivery date: 6-12 days

80 Amps AC Contactor Features

The bypass AC contactor is suitable for using in the circuits up to the rated voltage 380V/660V AC 50Hz or 60Hz, rated current up to 80A, contactor for controlling, starting, breaking and reversing of the motor. Not only full set accessories but also more pretty.

80 Amps AC Contactor Specification

ModelATO-CJX2-80
Rated Operational Current (AC-3)380V80A
660V49A
Conventional Heating Current110A
Rated Insulation Voltage690V
Power of Controllable 3-phase Squirrel-cage Motor (AC-3)220V22kW
380V37kW
660V45kW
Operational Frequency (AC-3)Electric Life600 times/h
Mechanical Life2400 times/h
Service LifeElectric Life (104 times)60
Mechanical Life (104 times)600
Matching Fusing ModelRT16-100
Average Power Consumption (20℃) @ 50HzPick-up230VA
Holding32VA
Unit weught(kg)4P (4N/O)1.59
4P (2N/O+2N/C)1.65
Ambient Temperature-5℃~+40℃
Altittude≤2000m
Rail Size75mm
Class of PollutionClass 3
Installation CategoryⅢ

80 Amps AC Contactor Dimensions

4P (4NO) AC contactor

 Cjx2 ac contact 80004

4P (2NO+2NC) AC contactor

Cjx2 ac contact 80008

Tips: Classification of AC contactors

  • According to the number of poles of the main contact, it can be divided into single-pole, bipolar, three-pole, four-pole and five-pole contactors. Monopole is mainly used for single-phase load. Bipolar is used in the rotor circuit of wound-type asynchronous motor. Three-pole is used for three-phase load and is most widely used. Four-pole is mainly used for three-phase four-wire lighting circuit. Extremely used to form an auto-compensation starter or to control a double-cage motor.
  • According to the arc extinguishing medium, it can be divided into air contactor, vacuum contactor and the like. Contactors that rely on air insulation are used for general loads, while contactors that use vacuum insulation are commonly used in coal mines, petroleum, chemical companies, etc.
  • According to the presence or absence of contact points, it can be divided into contact contactors and contactless contactors. Common contactors are mostly contact contactors, and contactless contactors are the product of electronic technology applications, generally using thyristors as the switching elements of the circuit.

How to Use AC Contactor with Relay Under Safe Voltage?

Contactors are widely used in industrial equipment. It is a common application to control 110V/120V/220V/240V AC contactors with 12V/24V/36V DC relays. Users can use this method to control unsafe voltages. This video will show you how to use AC contactor with a relay at safe voltage.

Relay/Contactor Interlock Circuit Wiring

In this video, the wiring method of the relay/contactor interlock circuit is demonstrated.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Works great!
5
He
Avatar
11/14/2018 7:14 PM
This Contactor went into place smoothly and with no problems.
Once installed, it worked perfectly.
And very affordable.
Was this review helpful? Yes No (0/0)
Matching auxiliary contact module
5
Kuolina
Avatar
10/22/2026 9:02 PM
I purchased one of the contactors, ATO-ACCON-080, from you. Does it come with a matching auxiliary contact module?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can be equipped with a 2NO+2NC auxiliary contact module.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

80 Amps AC Contactor Features

The bypass AC contactor is suitable for using in the circuits up to the rated voltage 380V/660V AC 50Hz or 60Hz, rated current up to 80A, contactor for controlling, starting, breaking and reversing of the motor. Not only full set accessories but also more pretty.

80 Amps AC Contactor Specification

ModelATO-CJX2-80
Rated Operational Current (AC-3)380V80A
660V49A
Conventional Heating Current110A
Rated Insulation Voltage690V
Power of Controllable 3-phase Squirrel-cage Motor (AC-3)220V22kW
380V37kW
660V45kW
Operational Frequency (AC-3)Electric Life600 times/h
Mechanical Life2400 times/h
Service LifeElectric Life (104 times)60
Mechanical Life (104 times)600
Matching Fusing ModelRT16-100
Average Power Consumption (20℃) @ 50HzPick-up230VA
Holding32VA
Unit weught(kg)4P (4N/O)1.59
4P (2N/O+2N/C)1.65
Ambient Temperature-5℃~+40℃
Altittude≤2000m
Rail Size75mm
Class of PollutionClass 3
Installation CategoryⅢ

80 Amps AC Contactor Dimensions

4P (4NO) AC contactor

 Cjx2 ac contact 80004

4P (2NO+2NC) AC contactor

Cjx2 ac contact 80008

Tips: Classification of AC contactors

  • According to the number of poles of the main contact, it can be divided into single-pole, bipolar, three-pole, four-pole and five-pole contactors. Monopole is mainly used for single-phase load. Bipolar is used in the rotor circuit of wound-type asynchronous motor. Three-pole is used for three-phase load and is most widely used. Four-pole is mainly used for three-phase four-wire lighting circuit. Extremely used to form an auto-compensation starter or to control a double-cage motor.
  • According to the arc extinguishing medium, it can be divided into air contactor, vacuum contactor and the like. Contactors that rely on air insulation are used for general loads, while contactors that use vacuum insulation are commonly used in coal mines, petroleum, chemical companies, etc.
  • According to the presence or absence of contact points, it can be divided into contact contactors and contactless contactors. Common contactors are mostly contact contactors, and contactless contactors are the product of electronic technology applications, generally using thyristors as the switching elements of the circuit.
Product reviews
Works great!
5
He
Avatar
11/14/2018 7:14 PM
This Contactor went into place smoothly and with no problems.
Once installed, it worked perfectly.
And very affordable.
Was this review helpful? Yes No (0/0)
Matching auxiliary contact module
5
Kuolina
Avatar
10/22/2026 9:02 PM
I purchased one of the contactors, ATO-ACCON-080, from you. Does it come with a matching auxiliary contact module?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can be equipped with a 2NO+2NC auxiliary contact module.
Only registered users can write reviews