This lightweight and convenient bypass AC contactor with 4P (4NO) or 4P (2NO+2NC) contact form, it has a lot coil voltage to choose like 24V, 110V, 220V. And when the voltage is at 380V, the rated current is 50A; voltage is at 660V, rated current is 39A. 4 pole contactor relay can be used for a long time and is also affordable.
SKU: ATO-ACCON-050
*
*
Free Shipping
Delivery date: 6-12 days

50 Amps AC Contactor Features

The 50 Amps bypass AC contactor can control 15 kW 3-phase squirrel-cage motor under AC-3 220V, 22 kW motor under AC-3 380V, and 33kW motor under AC-3 660V. Low power consumption and widely used in various applications with frequency 50Hz/60Hz.

50 Amps AC Contactor Specifications

ModelATO-CJX2-50
Rated Operational Current (AC-3)380V50A
660V39A
Conventional Heating Current80A
Rated Insulation Voltage690V
Power of Controllable 3-phase Squirrel-cage Motor (AC-3)220V15kW
380V22kW
660V33kW
Operational Frequency (AC-3)Electric Life600 times/h
Mechanical Life3600 times/h
Service LifeElectric Life (104 times)60
Mechanical Life (104 times)800
Matching Fusing ModelRT16-63
Average Power Consumption (20℃) @ 50HzPick-up230VA
Holding32VA
Unit weught(kg)4P (4N/O)1.32
4P (2N/O+2N/C)1.37
Ambient Temperature-5℃~+40℃
Altittude≤2000m
Rail Size75mm
Class of PollutionClass 3
Installation CategoryⅢ

50 Amps AC Contactor Dimensions

4P (4NO) AC contact

cjx2-50

4P (2NO+2NC) AC contact

ac contactor

Tips

The contactor can be divided into an AC contactor and a DC contactor according to the type of the controlled current. AC contactors are widely used as breaking and control circuits for electric power. It uses the main contact to open and close the circuit, and the auxiliary contact to execute the control command. The main contacts generally have only normally open contacts, while the auxiliary contacts often have two pairs of contacts with normally open and normally closed functions. Small contactors are often used as intermediate relays in conjunction with the main circuit.

How to Use AC Contactor with Relay Under Safe Voltage?

Contactors are widely used in industrial equipment. It is a common application to control 110V/120V/220V/240V AC contactors with 12V/24V/36V DC relays. Users can use this method to control unsafe voltages. This video will show you how to use AC contactor with a relay at safe voltage.

Relay/Contactor Interlock Circuit Wiring

In this video, the wiring method of the relay/contactor interlock circuit is demonstrated.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
This 4 pole AC Contactor is highly recommended
5
Abner
Avatar
2/12/2023 6:24 PM
Highly recommend AC Contactor to anyone looking for a high quality, reliable and affordable solution for their home cooling needs. This 4 pole AC contactor has exceeded my expectations and I am confident that it will provide me with excellent service for years to come.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

50 Amps AC Contactor Features

The 50 Amps bypass AC contactor can control 15 kW 3-phase squirrel-cage motor under AC-3 220V, 22 kW motor under AC-3 380V, and 33kW motor under AC-3 660V. Low power consumption and widely used in various applications with frequency 50Hz/60Hz.

50 Amps AC Contactor Specifications

ModelATO-CJX2-50
Rated Operational Current (AC-3)380V50A
660V39A
Conventional Heating Current80A
Rated Insulation Voltage690V
Power of Controllable 3-phase Squirrel-cage Motor (AC-3)220V15kW
380V22kW
660V33kW
Operational Frequency (AC-3)Electric Life600 times/h
Mechanical Life3600 times/h
Service LifeElectric Life (104 times)60
Mechanical Life (104 times)800
Matching Fusing ModelRT16-63
Average Power Consumption (20℃) @ 50HzPick-up230VA
Holding32VA
Unit weught(kg)4P (4N/O)1.32
4P (2N/O+2N/C)1.37
Ambient Temperature-5℃~+40℃
Altittude≤2000m
Rail Size75mm
Class of PollutionClass 3
Installation CategoryⅢ

50 Amps AC Contactor Dimensions

4P (4NO) AC contact

cjx2-50

4P (2NO+2NC) AC contact

ac contactor

Tips

The contactor can be divided into an AC contactor and a DC contactor according to the type of the controlled current. AC contactors are widely used as breaking and control circuits for electric power. It uses the main contact to open and close the circuit, and the auxiliary contact to execute the control command. The main contacts generally have only normally open contacts, while the auxiliary contacts often have two pairs of contacts with normally open and normally closed functions. Small contactors are often used as intermediate relays in conjunction with the main circuit.

Product reviews
This 4 pole AC Contactor is highly recommended
5
Abner
Avatar
2/12/2023 6:24 PM
Highly recommend AC Contactor to anyone looking for a high quality, reliable and affordable solution for their home cooling needs. This 4 pole AC contactor has exceeded my expectations and I am confident that it will provide me with excellent service for years to come.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews