600A High Voltage DC Contactor, 9-36V Coil Voltage

$304.46
Good quality 600A DC contactor manufacturer direct sale, 9-36V coil voltage, NO contact form, non-polarity, and optional NO/NC auxiliary contact. This high voltage DC power contactor can be used to safely control and interrupt high-voltage DC circuits.
SKU: ATO-DCCON-600
*
Free Shipping
Delivery date: 6-12 days

High-voltage DC contactor is a high-voltage safety switch in DC systems. 600A DC contactor provides a 9-36V coil voltage, NO main contact form, non-polarity, and NO/NC auxiliary contact, commonly used in new energy vehicles, energy storage and photovoltaic systems, DC charging stations, and industrial and rail transportation applications.

Features

  • 600A DC contactor adopts high-strength epoxy resin sealing with nitrogen-based gas filling, eliminating arc leakage risks, preventing contact oxidation, and ensuring safe operation without fire or explosion during its service life.
  • It provides reliable performance with 600A continuous current at 85℃, IP67 contact protection, insulation resistance up to 100MΩ (1000V DC), and dielectric strength of 3.5kV between contacts and coil.
  • High voltage DC contactor meets IEC 60664-1, GB/T14048.1, GB/T14048.4 standards, complies with RoHS (2015/863/EU) and REACH (1907/2006/EC), and is certified by CE, CCC, and RoHS.

Specifications

ModelATO-ADH-600
Main Contact Specification
Contact Arrangement1K (1NO)
Contact PolarityNon-polarity
Contact Resistance≤0.5mΩ
Contact Voltage Drop≤0.1V (at 200A)
Max. Switching Voltage1,500V DC
Max. Breaking Current4,000A (320V DC) 1 Ops
Electrical Endurance (Resistive Load)1,000 Ops (1,000V DC, 600A)
2,000 Ops (750V DC, 600A)
3,000 Ops (450V DC, 600A)
Mechanical Endurance200,000 Ops
Withstand Current600A, Continuous
750A, 90s
1,000A, 40s
2,100A, 1s
18,000A, 10ms
Performance Parameter (at 23℃)
Pickup VoltageSee Coil Parameter Tables
Dropout VoltageSee Coil Parameter Tables
Pickup Time≤40ms
Contact Bounce Period≤5ms
Dropout Time≤10ms
Dielectric StrengthBetween Main Contacts10,000V DC 1 min, Leakage Current≤1mA
Between Main Contact and Coil3,500V DC 1min, Leakage Current≤1mA
Insulation ResistanceInitial State1,000MΩ (1,500V DC 1min)
After Electrical Life500MΩ (1,500V DC 1min)
ShockStability20g (Power On)
Strength50g
Vibration20g, 80~2,000Hz, 1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Temperature-40℃~85℃
Load TerminalExternal Thread M10
WeightAbout 1000g
Dimension67x75.5x104mm
Installation MethodBottom Installation
Temperature RiseMain Contact Temperature Rise≤50K (370mm2, 600A Continuous)
Auxiliary Contact Parameter
Aux. Contact ArrangementFK/FB/FZ (1NO/1NC/1CO)
Aux. Contact Rated Current5A
Aux. Contact Max. Breaking Voltage120V DC
Coil Parameter
Coil Voltage9-36V
Pickup Voltage (DC)9-36V
Dropout Voltage (DC)5-7V
Coil Resistance1.8Ω±10%
Starting Current≤4A
Holding Power≤8W


Dimensions (Unit: mm)

600A high voltage DC contactor without auxiliary switch dimension

600A high voltage DC contactor with auxiliary switch dimension

600A high voltage DC contactor with auxiliary switch dimension-1

Wiring Diagram

Note: A1&A2 main terminals with non-polarity; 3&4&5 auxiliary contact terminals; 1&2 Circuit diagram 9-36V.

600A high voltage DC contactor wiring diagram

Applications

High voltage DC contactors are widely applied in electric vehicles (EVs), renewable energy systems (solar and wind), energy storage systems (ESS), DC charging stations, uninterruptible power supplies (UPS), and industrial equipment that requires safe and reliable DC switching.

500A high\ voltage DC contactor applications

Tips: Where is a 600A high voltage DC contactor commonly applied?

The 600A high voltage DC contactor is commonly applied in electric vehicles, energy storage systems, solar/wind inverter systems, and industrial power control equipment. In these environments, it acts as a safety switch and protective device, allowing operators to disconnect circuits when needed and preventing failures caused by short circuits or overloads. Its balance of current capacity and compact size makes it especially suitable for mid-to-high power applications where reliability is essential.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High-voltage DC contactor is a high-voltage safety switch in DC systems. 600A DC contactor provides a 9-36V coil voltage, NO main contact form, non-polarity, and NO/NC auxiliary contact, commonly used in new energy vehicles, energy storage and photovoltaic systems, DC charging stations, and industrial and rail transportation applications.

Features

  • 600A DC contactor adopts high-strength epoxy resin sealing with nitrogen-based gas filling, eliminating arc leakage risks, preventing contact oxidation, and ensuring safe operation without fire or explosion during its service life.
  • It provides reliable performance with 600A continuous current at 85℃, IP67 contact protection, insulation resistance up to 100MΩ (1000V DC), and dielectric strength of 3.5kV between contacts and coil.
  • High voltage DC contactor meets IEC 60664-1, GB/T14048.1, GB/T14048.4 standards, complies with RoHS (2015/863/EU) and REACH (1907/2006/EC), and is certified by CE, CCC, and RoHS.

Specifications

ModelATO-ADH-600
Main Contact Specification
Contact Arrangement1K (1NO)
Contact PolarityNon-polarity
Contact Resistance≤0.5mΩ
Contact Voltage Drop≤0.1V (at 200A)
Max. Switching Voltage1,500V DC
Max. Breaking Current4,000A (320V DC) 1 Ops
Electrical Endurance (Resistive Load)1,000 Ops (1,000V DC, 600A)
2,000 Ops (750V DC, 600A)
3,000 Ops (450V DC, 600A)
Mechanical Endurance200,000 Ops
Withstand Current600A, Continuous
750A, 90s
1,000A, 40s
2,100A, 1s
18,000A, 10ms
Performance Parameter (at 23℃)
Pickup VoltageSee Coil Parameter Tables
Dropout VoltageSee Coil Parameter Tables
Pickup Time≤40ms
Contact Bounce Period≤5ms
Dropout Time≤10ms
Dielectric StrengthBetween Main Contacts10,000V DC 1 min, Leakage Current≤1mA
Between Main Contact and Coil3,500V DC 1min, Leakage Current≤1mA
Insulation ResistanceInitial State1,000MΩ (1,500V DC 1min)
After Electrical Life500MΩ (1,500V DC 1min)
ShockStability20g (Power On)
Strength50g
Vibration20g, 80~2,000Hz, 1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Temperature-40℃~85℃
Load TerminalExternal Thread M10
WeightAbout 1000g
Dimension67x75.5x104mm
Installation MethodBottom Installation
Temperature RiseMain Contact Temperature Rise≤50K (370mm2, 600A Continuous)
Auxiliary Contact Parameter
Aux. Contact ArrangementFK/FB/FZ (1NO/1NC/1CO)
Aux. Contact Rated Current5A
Aux. Contact Max. Breaking Voltage120V DC
Coil Parameter
Coil Voltage9-36V
Pickup Voltage (DC)9-36V
Dropout Voltage (DC)5-7V
Coil Resistance1.8Ω±10%
Starting Current≤4A
Holding Power≤8W


Dimensions (Unit: mm)

600A high voltage DC contactor without auxiliary switch dimension

600A high voltage DC contactor with auxiliary switch dimension

600A high voltage DC contactor with auxiliary switch dimension-1

Wiring Diagram

Note: A1&A2 main terminals with non-polarity; 3&4&5 auxiliary contact terminals; 1&2 Circuit diagram 9-36V.

600A high voltage DC contactor wiring diagram

Applications

High voltage DC contactors are widely applied in electric vehicles (EVs), renewable energy systems (solar and wind), energy storage systems (ESS), DC charging stations, uninterruptible power supplies (UPS), and industrial equipment that requires safe and reliable DC switching.

500A high\ voltage DC contactor applications

Tips: Where is a 600A high voltage DC contactor commonly applied?

The 600A high voltage DC contactor is commonly applied in electric vehicles, energy storage systems, solar/wind inverter systems, and industrial power control equipment. In these environments, it acts as a safety switch and protective device, allowing operators to disconnect circuits when needed and preventing failures caused by short circuits or overloads. Its balance of current capacity and compact size makes it especially suitable for mid-to-high power applications where reliability is essential.

Only registered users can write reviews