1000A High Voltage DC Contactor, 9-36V Coil Voltage

$462.92
1000A high voltage DC contactor for sale online. The DC magnetic contactor is available with 9-36V coil voltage, NO contact form, normally open or normally closed auxiliary contact switch, CE, CCC, and RoHS certifications.
SKU: ATO-DCCON-1000
*
Free Shipping
Delivery date: 6-12 days

Quality 1000A DC contactor manufacturer direct sale, 9-36V coil voltage, a NO contact form, non-polarity, NO or NC auxiliary contact. High voltage DC power contactor can withstand a continuous current of 1000A at 85°C and boast an insulation resistance of up to 100MΩ (1000V DC), used to safely control and interrupt high-voltage DC circuits.

Features

  • 1000A DC contactor adopts high-strength epoxy resin sealing with nitrogen-based gas filling, eliminating arc leakage risks, preventing contact oxidation, and ensuring safe operation without fire or explosion during its service life.
  • It provides reliable performance with 1000A continuous current at 85℃, IP67 contact protection, insulation resistance up to 100MΩ (1000V DC), and dielectric strength of 5kV between contacts and coil.
  • High voltage DC contactor meets IEC 60664-1, GB/T14048.1, GB/T14048.4 standards, complies with RoHS (2015/863/EU) and REACH (1907/2006/EC), and is certified by CE, CCC, and RoHS.

Specifications

ModelATO-ADH-1000
Main Contact Specification
Contact Arrangement1K (1NO)
Contact PolarityNon-polarity
Contact Resistance≤0.5mΩ (at 1000A)
Max. Switching Voltage1,000V DC
Max. Breaking Current2,000A (320V DC) 1 Ops
Electrical Endurance (Resistive Load)500 Ops (1,000V DC, 1000A)
1,000 Ops (750V DC, 1000A)
2,000 Ops (500V DC, 1000A)
Mechanical Endurance100,000 Ops
Withstand Current1000A, Continuous
20000A, 120s
3,000A, 30s
18,000A, 10ms
Performance Parameter (at 23℃)
Pickup VoltageSee Coil Parameter Tables
Dropout VoltageSee Coil Parameter Tables
Pickup Time≤50ms
Contact Bounce Period≤5ms
Dropout Time≤20ms
Dielectric StrengthBetween Main Contacts10,000V AC 10s
Between Main Contact and Coil3,500V DC 1min
Insulation ResistanceInitial State100MΩ 1min
After Electrical Life50MΩ 1 min
ShockStability20g (Power On)
Strength50g
Vibration10g, 10~500Hz, 1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Temperature-40℃~85℃
Load TerminalBusbar
WeightAbout 3300g
Dimension127x106x144mm
Auxiliary Contact Parameter
Aux. Contact ArrangementFK/FB/FZ (1NO/1NC/1CO)
Aux. Contact Rated Current5A
Aux. Contact Max. Breaking Voltage120V DC
Coil Parameter
Coil Voltage9-36V
Pickup Voltage (DC)9-36V
Dropout Voltage (DC)5-7V
Coil Resistance1.8Ω±10%
Starting Power≤100W
Holding Power≤9W


Dimensions (Unit: mm)

1000A high voltage DC contactor without auxiliary switch dimension

1000A high voltage DC contactor with auxiliary switch dimension

Wiring Diagram

Note: A1&A2 main terminals with non-polarity; 3&4 auxiliary contact terminals; 1&2 coil terminals 9-36V.

1000A high voltage DC contactor wiring diagram

Applications

High voltage DC contactors are widely applied in electric vehicles (EVs), renewable energy systems (solar and wind), energy storage systems (ESS), DC charging stations, uninterruptible power supplies (UPS), and industrial equipment that requires safe and reliable DC switching.

500A high\ voltage DC contactor applications

Tips: Why is a 1000A DC contactor important for high-capacity applications?

High-capacity applications such as grid-scale energy storage, EV fast charging stations, and heavy industrial systems often operate at both high current and high voltage. A 1000A DC contactor provides the necessary robustness to handle these extreme conditions. Without it, systems could suffer from overheating, inefficient power transfer, or unsafe disconnections. Its design ensures stability, safety, and efficiency in critical power applications.

Product reviews
Working Principle
5
Pena
Avatar
12/21/2025 7:31 PM
Hello, product number: ATO-DCCON-1000 or product number: ATO-DCCON-HV800. I am installing two amplifiers in my car, one of which requires a 700-amp fuse. I would like to understand their respective working principles and how to isolate my 12-volt main battery from the 14-volt audio system? Thank you for your prompt reply.
Was this review helpful? Yes No (0/0)
ATO Responded
Thank you for your inquiry. High-voltage DC contactors essentially use electromagnetic control to switch high current. When the coil is connected to the 12V battery, it is energized and engages, conducting power to the audio system; when the power is off, the contacts open, achieving safe isolation. If you are using it in a car, we recommend the ATO-DCCON-HV800, which is smaller and has a higher protection level.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Quality 1000A DC contactor manufacturer direct sale, 9-36V coil voltage, a NO contact form, non-polarity, NO or NC auxiliary contact. High voltage DC power contactor can withstand a continuous current of 1000A at 85°C and boast an insulation resistance of up to 100MΩ (1000V DC), used to safely control and interrupt high-voltage DC circuits.

Features

  • 1000A DC contactor adopts high-strength epoxy resin sealing with nitrogen-based gas filling, eliminating arc leakage risks, preventing contact oxidation, and ensuring safe operation without fire or explosion during its service life.
  • It provides reliable performance with 1000A continuous current at 85℃, IP67 contact protection, insulation resistance up to 100MΩ (1000V DC), and dielectric strength of 5kV between contacts and coil.
  • High voltage DC contactor meets IEC 60664-1, GB/T14048.1, GB/T14048.4 standards, complies with RoHS (2015/863/EU) and REACH (1907/2006/EC), and is certified by CE, CCC, and RoHS.

Specifications

ModelATO-ADH-1000
Main Contact Specification
Contact Arrangement1K (1NO)
Contact PolarityNon-polarity
Contact Resistance≤0.5mΩ (at 1000A)
Max. Switching Voltage1,000V DC
Max. Breaking Current2,000A (320V DC) 1 Ops
Electrical Endurance (Resistive Load)500 Ops (1,000V DC, 1000A)
1,000 Ops (750V DC, 1000A)
2,000 Ops (500V DC, 1000A)
Mechanical Endurance100,000 Ops
Withstand Current1000A, Continuous
20000A, 120s
3,000A, 30s
18,000A, 10ms
Performance Parameter (at 23℃)
Pickup VoltageSee Coil Parameter Tables
Dropout VoltageSee Coil Parameter Tables
Pickup Time≤50ms
Contact Bounce Period≤5ms
Dropout Time≤20ms
Dielectric StrengthBetween Main Contacts10,000V AC 10s
Between Main Contact and Coil3,500V DC 1min
Insulation ResistanceInitial State100MΩ 1min
After Electrical Life50MΩ 1 min
ShockStability20g (Power On)
Strength50g
Vibration10g, 10~500Hz, 1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Temperature-40℃~85℃
Load TerminalBusbar
WeightAbout 3300g
Dimension127x106x144mm
Auxiliary Contact Parameter
Aux. Contact ArrangementFK/FB/FZ (1NO/1NC/1CO)
Aux. Contact Rated Current5A
Aux. Contact Max. Breaking Voltage120V DC
Coil Parameter
Coil Voltage9-36V
Pickup Voltage (DC)9-36V
Dropout Voltage (DC)5-7V
Coil Resistance1.8Ω±10%
Starting Power≤100W
Holding Power≤9W


Dimensions (Unit: mm)

1000A high voltage DC contactor without auxiliary switch dimension

1000A high voltage DC contactor with auxiliary switch dimension

Wiring Diagram

Note: A1&A2 main terminals with non-polarity; 3&4 auxiliary contact terminals; 1&2 coil terminals 9-36V.

1000A high voltage DC contactor wiring diagram

Applications

High voltage DC contactors are widely applied in electric vehicles (EVs), renewable energy systems (solar and wind), energy storage systems (ESS), DC charging stations, uninterruptible power supplies (UPS), and industrial equipment that requires safe and reliable DC switching.

500A high\ voltage DC contactor applications

Tips: Why is a 1000A DC contactor important for high-capacity applications?

High-capacity applications such as grid-scale energy storage, EV fast charging stations, and heavy industrial systems often operate at both high current and high voltage. A 1000A DC contactor provides the necessary robustness to handle these extreme conditions. Without it, systems could suffer from overheating, inefficient power transfer, or unsafe disconnections. Its design ensures stability, safety, and efficiency in critical power applications.

Product reviews
Working Principle
5
Pena
Avatar
12/21/2025 7:31 PM
Hello, product number: ATO-DCCON-1000 or product number: ATO-DCCON-HV800. I am installing two amplifiers in my car, one of which requires a 700-amp fuse. I would like to understand their respective working principles and how to isolate my 12-volt main battery from the 14-volt audio system? Thank you for your prompt reply.
Was this review helpful? Yes No (0/0)
ATO Responded
Thank you for your inquiry. High-voltage DC contactors essentially use electromagnetic control to switch high current. When the coil is connected to the 12V battery, it is energized and engages, conducting power to the audio system; when the power is off, the contacts open, achieving safe isolation. If you are using it in a car, we recommend the ATO-DCCON-HV800, which is smaller and has a higher protection level.
Only registered users can write reviews