250A DC Contactor, 12V/24V/48V

$80.11
The provided DC contactor is used for hydraulic power units, electric forklifts, and electric haul trucks applications, available with a short-term 250A load, 12V/24V/36V/48V/60V/72V coil voltage, and normally open contact form. 2 different installation methods are optional.
SKU: ATO-DCCON-C250
*
*
Free Shipping
Delivery date: 6-12 days

250A DC contactor comes with a normally open contact form, IP67 waterproof rating, CE and RoHS certificates, high performance, and low power consumption. 12V/24V/36V/48V/60V/72V coil voltage can be selected.

Features

  • The DC contactor supports a short-term 250A load, features one normally open contact, and has a coil power consumption of ≤22W.
  • It provides an insulation resistance of 100MΩ (1000VDC), a dielectric strength of 2kV between contacts and coil, and an IP67 protection rating.
  • 250A DC contactor complies with IEC 60664-1, GB/T14048.1, and GB/T14048.4 standards, meets RoHS (2015/863/EU) and REACH (1907/2006/EC) requirements, and is CE certified.

Specifications

ModelATO-ADD-250I
Performance Parameter (at 23℃)
Contact Arrangement1K(1NO)
Contact Resistance≤5mΩ
Contact Voltage Drop≤80mV (at 150A)
Overload Current≤7le,>1s
Temperature-40℃~55℃
Load TerminalM8 External Thread
Vibration3.5g,10~200Hz,1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Dimension76.8x70.6x68.5mm
Operating DutyIntermittent
Electrical Durability with Load (Resistive)≥50,000 times(24V/300A)
Load Wiring Torque8-10N.m
Pickup Voltage70%Us
Dropout Voltage5%-40%Us
Contact Bounce Period≤5ms
Pickup Time≤30ms
Dropout Time≤30ms
Dielectric StrengthBetween Main Contacts50Hz/60Hz 1500V AC/1min
Between Main Contacts and Coil50Hz/60Hz 1500V AC/1min
Insulation ResistanceInitial State100MΩ 1min
After Electrical Life50MΩ 1min
ShockStability20g(Power On)
Strength50g
Mechanical Durability≥500,000 times
Coil Wiring Torque2-3N.m


Coil Parameter

Coil VoltagePickup Voltage (VDC)Dropout Voltage (VDC)Coil ResistanceCoil Power Consumption
12V≤70%Us5-40%Us6Ω±10%24W±10%
24V≤70%Us5-40%Us24Ω±10%24W±10%
36v≤70%Us5-40%Us54Ω±10%24W±10%
48V≤70%Us5-40%Us96Ω±10%24W±10%
60V≤70%Us5-40%Us150Ω±10%24W±10%
72V≤70%Us5-40%Us216Ω±10%24W±10%


Dimensions (Unit: mm)

Side Cambered Installation

250A DC contactor dimension

Side Flat Mounting

250A DC contactor dimension

Wiring Diagram

250A DC contactor wiring diagram

Applications

ATO DC contactors are widely applied in electric vehicles (EVs), renewable energy systems (solar and wind), energy storage systems (ESS), DC charging stations, uninterruptible power supplies (UPS), and industrial equipment that requires safe and reliable DC switching.

350A high\ voltage DC contactor applications

Tips: When should I choose a low-current DC contactor and when a high-current model?

You should choose a DC contactor based on your system maximum operating current

  • Low current DC contactors for example 40A are suitable for low to medium current applications such as battery management modules UPS auxiliary circuits or solar storage system branch circuits. They offer smaller size lower cost and lower coil power consumption.
  • High current contactors for example 150A or more are required for high current applications such as electric vehicle main battery circuits large energy storage systems or industrial DC power supplies. They can handle startup surges short term overloads and heavy loads safely.

Rule of thumb is to always select a contactor rated slightly above the system maximum continuous current to ensure safe and reliable operation.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

250A DC contactor comes with a normally open contact form, IP67 waterproof rating, CE and RoHS certificates, high performance, and low power consumption. 12V/24V/36V/48V/60V/72V coil voltage can be selected.

Features

  • The DC contactor supports a short-term 250A load, features one normally open contact, and has a coil power consumption of ≤22W.
  • It provides an insulation resistance of 100MΩ (1000VDC), a dielectric strength of 2kV between contacts and coil, and an IP67 protection rating.
  • 250A DC contactor complies with IEC 60664-1, GB/T14048.1, and GB/T14048.4 standards, meets RoHS (2015/863/EU) and REACH (1907/2006/EC) requirements, and is CE certified.

Specifications

ModelATO-ADD-250I
Performance Parameter (at 23℃)
Contact Arrangement1K(1NO)
Contact Resistance≤5mΩ
Contact Voltage Drop≤80mV (at 150A)
Overload Current≤7le,>1s
Temperature-40℃~55℃
Load TerminalM8 External Thread
Vibration3.5g,10~200Hz,1/2 Sine Wave (Power On)
Relative Humidity5%~95%RH
Dimension76.8x70.6x68.5mm
Operating DutyIntermittent
Electrical Durability with Load (Resistive)≥50,000 times(24V/300A)
Load Wiring Torque8-10N.m
Pickup Voltage70%Us
Dropout Voltage5%-40%Us
Contact Bounce Period≤5ms
Pickup Time≤30ms
Dropout Time≤30ms
Dielectric StrengthBetween Main Contacts50Hz/60Hz 1500V AC/1min
Between Main Contacts and Coil50Hz/60Hz 1500V AC/1min
Insulation ResistanceInitial State100MΩ 1min
After Electrical Life50MΩ 1min
ShockStability20g(Power On)
Strength50g
Mechanical Durability≥500,000 times
Coil Wiring Torque2-3N.m


Coil Parameter

Coil VoltagePickup Voltage (VDC)Dropout Voltage (VDC)Coil ResistanceCoil Power Consumption
12V≤70%Us5-40%Us6Ω±10%24W±10%
24V≤70%Us5-40%Us24Ω±10%24W±10%
36v≤70%Us5-40%Us54Ω±10%24W±10%
48V≤70%Us5-40%Us96Ω±10%24W±10%
60V≤70%Us5-40%Us150Ω±10%24W±10%
72V≤70%Us5-40%Us216Ω±10%24W±10%


Dimensions (Unit: mm)

Side Cambered Installation

250A DC contactor dimension

Side Flat Mounting

250A DC contactor dimension

Wiring Diagram

250A DC contactor wiring diagram

Applications

ATO DC contactors are widely applied in electric vehicles (EVs), renewable energy systems (solar and wind), energy storage systems (ESS), DC charging stations, uninterruptible power supplies (UPS), and industrial equipment that requires safe and reliable DC switching.

350A high\ voltage DC contactor applications

Tips: When should I choose a low-current DC contactor and when a high-current model?

You should choose a DC contactor based on your system maximum operating current

  • Low current DC contactors for example 40A are suitable for low to medium current applications such as battery management modules UPS auxiliary circuits or solar storage system branch circuits. They offer smaller size lower cost and lower coil power consumption.
  • High current contactors for example 150A or more are required for high current applications such as electric vehicle main battery circuits large energy storage systems or industrial DC power supplies. They can handle startup surges short term overloads and heavy loads safely.

Rule of thumb is to always select a contactor rated slightly above the system maximum continuous current to ensure safe and reliable operation.

Only registered users can write reviews
Customers who bought this item also bought

Digital Over and Under Voltage Protector, 63A/80A/100A

ATO-OVP-80A
$66.77
Auto reste digital over and under voltage protector is equipped with 63A/80A/100A current, 2 pole or 4 pole, clear display, flame retardant housing, and supports rail mounting, used to protect circuits or electrical equipment from damage caused by excessive high or low voltage.