400 amp 3 phase AC Magnetic Contactor, 24V/110V/220V Coil

$698.33
3 phase AC magnetic contactor at economical price, 3 pole, with rated current up to 400 amps, is mainly used in switching and controlling electric motors for industrial applications. This AC contactor relay has a wide selection of coils voltage and contact form.
SKU: ATO-ACCON-400A
*
*
Free Shipping
Delivery date: 6-12 days

3 pole 3 phase AC magnetic contactor with 24V/110V/220V coils is a form of electrical relay found on electric motors. It is used for long distance breaking circuit and frequently starting or controlling motors.

Specification

ModelATO-CJX2-F400
Rated Currentle max AC-3 (Ue≤440V)400A
le max AC-1 (θ≤40°C)500A
Coil Rated Voltage (Optional)110V AC, 220V AC, 380V AC
Contact Form3NO
Auxiliary Contact (Optional)2NO, 2NC, 1NO+1NC, 2NO+2NC, 1NC+3NO, 4NO, 4NC
Frequency50Hz/ 60Hz
Rated Insulated Voltage (Ui)1000V
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage440V
Conventional Thermal Current (θ≤40°C)500A
Operation FrequencyAC-1, AC-2, AC-3600 times/h
AC-4300A
Rated Power (AC-3)220/240V110kW
380/400V200kW
415V220kW
440V250kW
500V257kW
660/690V280kW
1000V185kW
Connection/ WiringNumber of Lines2
Line Size30x5mm2
Cable with Splicing2x150mm2
Screw Diameterφ10
Tightening Torque35N.m
Standards-CompliantIEC60947-4-1, GB14048.4, EN60947-4-1
Dimensions206 x 213 x 219mm
Weight19.5kg

Details

400 amp 3 phase AC Magnetic Contactor Details

Tips: Why do you need to buy an ATO AC magnetic contactor?

The AC magnetic contactor is generally used to start and control equipment. It uses different control wiring methods to control the forward and reverse rotation, start and stop of the electrical motor, and can realize remote control by controlling the length of the cable. Changing the connection can also realize multiple controls. In the state of power failure, the motor can be stopped to prevent it from running due to the power on again, which will protect the operators from unforeseen injuries. Of course, the motor can be started manually after the power goes on again. The AC contactor can be used together with an overheating relay or a motor protector to achieve the purpose of protecting the motor.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Some questions about AC magnetic contactor
5
lailli
Avatar
6/12/2023 9:44 PM
I’m not sure that I have the right part. Here is a picture of the contacts that I received. My understanding is that these would have normally closed contacts, rather than normally open contacts.  
I need normally closed contacts for the 400Amp connection itself, not for ancillaries. I need to make sure that the main contacts are normally closed so that they only open when I energize the coil.
Was this review helpful? Yes No (0/0)
ATO Responded
The contact has Mo main circuit normally closed contacts, only normally open contacts.
Only auxiliary contacts can be normally closed.
But do not worry, we will resend you the normally closed auxiliary contact parts.
Contactor recommendation
5
Kerigou
Avatar
6/3/2025 8:59 PM
I need a contactor for the soft starter. I found that the contactor coil needs 220 volts to adapt to my system. Do you have any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend our ATO-CJX2-F400 contactor, which has a coil voltage of 220 volts.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3 pole 3 phase AC magnetic contactor with 24V/110V/220V coils is a form of electrical relay found on electric motors. It is used for long distance breaking circuit and frequently starting or controlling motors.

Specification

ModelATO-CJX2-F400
Rated Currentle max AC-3 (Ue≤440V)400A
le max AC-1 (θ≤40°C)500A
Coil Rated Voltage (Optional)110V AC, 220V AC, 380V AC
Contact Form3NO
Auxiliary Contact (Optional)2NO, 2NC, 1NO+1NC, 2NO+2NC, 1NC+3NO, 4NO, 4NC
Frequency50Hz/ 60Hz
Rated Insulated Voltage (Ui)1000V
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage440V
Conventional Thermal Current (θ≤40°C)500A
Operation FrequencyAC-1, AC-2, AC-3600 times/h
AC-4300A
Rated Power (AC-3)220/240V110kW
380/400V200kW
415V220kW
440V250kW
500V257kW
660/690V280kW
1000V185kW
Connection/ WiringNumber of Lines2
Line Size30x5mm2
Cable with Splicing2x150mm2
Screw Diameterφ10
Tightening Torque35N.m
Standards-CompliantIEC60947-4-1, GB14048.4, EN60947-4-1
Dimensions206 x 213 x 219mm
Weight19.5kg

Details

400 amp 3 phase AC Magnetic Contactor Details

Tips: Why do you need to buy an ATO AC magnetic contactor?

The AC magnetic contactor is generally used to start and control equipment. It uses different control wiring methods to control the forward and reverse rotation, start and stop of the electrical motor, and can realize remote control by controlling the length of the cable. Changing the connection can also realize multiple controls. In the state of power failure, the motor can be stopped to prevent it from running due to the power on again, which will protect the operators from unforeseen injuries. Of course, the motor can be started manually after the power goes on again. The AC contactor can be used together with an overheating relay or a motor protector to achieve the purpose of protecting the motor.

Product reviews
Some questions about AC magnetic contactor
5
lailli
Avatar
6/12/2023 9:44 PM
I’m not sure that I have the right part. Here is a picture of the contacts that I received. My understanding is that these would have normally closed contacts, rather than normally open contacts.  
I need normally closed contacts for the 400Amp connection itself, not for ancillaries. I need to make sure that the main contacts are normally closed so that they only open when I energize the coil.
Was this review helpful? Yes No (0/0)
ATO Responded
The contact has Mo main circuit normally closed contacts, only normally open contacts.
Only auxiliary contacts can be normally closed.
But do not worry, we will resend you the normally closed auxiliary contact parts.
Contactor recommendation
5
Kerigou
Avatar
6/3/2025 8:59 PM
I need a contactor for the soft starter. I found that the contactor coil needs 220 volts to adapt to my system. Do you have any recommendations?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend our ATO-CJX2-F400 contactor, which has a coil voltage of 220 volts.
Only registered users can write reviews
Customers who bought this item also bought

3 Pole Molded Case Circuit Breaker, 250A/ 300A/ 350A/ 400A

ATO-MCCB-4003P
$307.14
3 pole molded case circuit breaker for sales online. Mccb circuit breaker with rated operating voltage 380/415V AC, 50Hz/ 60Hz, operating temperature from -25℃ to 50℃. The 400 amp mccb can be used for conversion of line and infrequent starting motor.