265 amp 3 phase AC Magnetic Contactor, 24V/110V/220V Coil

$583.28
ATO 3 pole 3 phase AC magnetic contactor with rated current up to 265A, 24V/110V/220V coils, is suitable for switching and controlling electric motors for industrial applications. This AC contactor relay has a wide selection of contact form to choose from.
SKU: ATO-ACCON-265A
*
*
Free Shipping
Delivery date: 6-12 days

3 pole AC magnetic contactor is used in 3 phase units. This contactor relay works between power source and high load electrical motor to balance changes in electrical frequency which may come from a power supply.

Specification

ModelATO-CJX2-F265
Rated Currentle max AC-3 (Ue≤440V)265A
le max AC-1 (θ≤40°C)350A
Coil Rated Voltage (Optional)110V AC, 220V AC, 380V AC
Contact Form3NO
Auxiliary Contact (Optional)2NO, 2NC, 1NO+1NC, 2NO+2NC, 1NC+3NO, 4NO, 4NC
Frequency50Hz/ 60Hz
Rated Insulated Voltage (Ui)1000V
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage440V
Conventional Thermal Current (θ≤40°C)350A
Operation FrequencyAC-1, AC-2, AC-31200 times/h
AC-4300A
Rated Power (AC-3)220/240V75kW
380/400V132kW
415V140kW
440V140kW
500V160kW
660/690V160kW
1000V147kW
Connection/ WiringNumber of Lines2
Line Size32x4mm2
Cable with Splicing240mm2
Cable with Connector240mm2
Screw Diameterφ10
Tightening Torque35N.m
Standards-CompliantIEC60947-4-1, GB14048.4, EN60947-4-1
Dimensions203 x 201.5 x 213mm
Weight16kg

Details

265 amp 3 phase AC Magnetic Contactor Details

Tips: Three attributes of AC magnetic contactor

  • AC magnetic contactor coil. Coils are usually identified by A1 and A2, which can be simply divided into AC contactors and DC contactors.
  • Main contact of AC contactor. L1-L2-L3 is connected to the three-phase power supply line, and T1–T2-T3 is connected to the power supply line, which can be used to connect the load line. The main contacts of AC contactors are normally open contacts, which are mainly connected to the main circuit to control the start and stop of motors and other equipment.
  • Auxiliary contact of AC contactor. Auxiliary contacts can be divided into normally open point NO and normally closed point NC. In general, the normally open point NO is mainly used for contactor self-locking control and transmission of operating signals. For example, AC contactor normally open point NO connected to a red indicator light can be used as the electrical motor’s running indicator light. When power is on, the normally open point NO is closed and the indicator light is turned on to transmit the operating signal of the motor or circuit. The normally closed point NC of the AC contactor is mainly used for circuit interlocking and signal transmission.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Works Well in Our Setup
5
Aurelia
Avatar
9/28/2026 6:56 PM
We’ve been using this AC magnetic contactor for motor control in our equipment, and it has worked reliably so far. The coil voltage options made it easy to match our control circuit, and the different contact configurations gave us more flexibility during installation.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3 pole AC magnetic contactor is used in 3 phase units. This contactor relay works between power source and high load electrical motor to balance changes in electrical frequency which may come from a power supply.

Specification

ModelATO-CJX2-F265
Rated Currentle max AC-3 (Ue≤440V)265A
le max AC-1 (θ≤40°C)350A
Coil Rated Voltage (Optional)110V AC, 220V AC, 380V AC
Contact Form3NO
Auxiliary Contact (Optional)2NO, 2NC, 1NO+1NC, 2NO+2NC, 1NC+3NO, 4NO, 4NC
Frequency50Hz/ 60Hz
Rated Insulated Voltage (Ui)1000V
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage440V
Conventional Thermal Current (θ≤40°C)350A
Operation FrequencyAC-1, AC-2, AC-31200 times/h
AC-4300A
Rated Power (AC-3)220/240V75kW
380/400V132kW
415V140kW
440V140kW
500V160kW
660/690V160kW
1000V147kW
Connection/ WiringNumber of Lines2
Line Size32x4mm2
Cable with Splicing240mm2
Cable with Connector240mm2
Screw Diameterφ10
Tightening Torque35N.m
Standards-CompliantIEC60947-4-1, GB14048.4, EN60947-4-1
Dimensions203 x 201.5 x 213mm
Weight16kg

Details

265 amp 3 phase AC Magnetic Contactor Details

Tips: Three attributes of AC magnetic contactor

  • AC magnetic contactor coil. Coils are usually identified by A1 and A2, which can be simply divided into AC contactors and DC contactors.
  • Main contact of AC contactor. L1-L2-L3 is connected to the three-phase power supply line, and T1–T2-T3 is connected to the power supply line, which can be used to connect the load line. The main contacts of AC contactors are normally open contacts, which are mainly connected to the main circuit to control the start and stop of motors and other equipment.
  • Auxiliary contact of AC contactor. Auxiliary contacts can be divided into normally open point NO and normally closed point NC. In general, the normally open point NO is mainly used for contactor self-locking control and transmission of operating signals. For example, AC contactor normally open point NO connected to a red indicator light can be used as the electrical motor’s running indicator light. When power is on, the normally open point NO is closed and the indicator light is turned on to transmit the operating signal of the motor or circuit. The normally closed point NC of the AC contactor is mainly used for circuit interlocking and signal transmission.
Product reviews
Works Well in Our Setup
5
Aurelia
Avatar
9/28/2026 6:56 PM
We’ve been using this AC magnetic contactor for motor control in our equipment, and it has worked reliably so far. The coil voltage options made it easy to match our control circuit, and the different contact configurations gave us more flexibility during installation.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews