185 amp 3 phase AC Magnetic Contactor, 24V/110V/220V Coil

$370.22
Low price 3 phase 3 pole AC magnetic contactor is used in electric motor control and DIN rail or panel mounting, with 110V/220V/380V coils. Different contact form are available, intended for frequently switching on and off 3 phase loads up to 185 amps.
SKU: ATO-ACCON-185A
*
*
Free Shipping
Delivery date: 6-12 days

ATO 3 pole AC magnetic contactor is used in 3 phase units. This contactor relay works between power source and high load electrical motor to balance changes in electrical frequency which may come from a power supply.

Specification

ModelATO-CJX2-F185
Rated Currentle max AC-3 (Ue≤440V)185A
le max AC-1 (θ≤40°C)275A
Coil Rated Voltage (Optional)110V AC, 220V AC, 380V AC
Contact Form3NO
Auxiliary Contact (Optional)2NO, 2NC, 1NO+1NC, 2NO+2NC, 1NC+3NO, 4NO, 4NC
Frequency50Hz/ 60Hz
Rated Insulated Voltage (Ui)1000V
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage440V
Conventional Thermal Current (θ≤40°C)275A
Operation FrequencyAC-1, AC-2, AC-31200 times/h
AC-4300A
Rated Power (AC-3)220/240V55kW
380/400V90kW
415V100kW
440V100kW
500V110kW
660/690V110kW
1000V100kW
Connection/ WiringNumber of Lines2
Line Size25x3mm2
Cable with Splicing150mm2
Cable with Connector150mm2
Screw Diameterφ8
Tightening Torque18N.m
Standards-CompliantIEC60947-4-1, GB14048.4, EN60947-4-1
Dimensions174 x 168.5 x 181mm
Weight9.5kg

Details

185 amp 3 phase AC Magnetic Contactor Details

Tips: Reasons for poor contact of the AC magnetic contactor

Poor contact of the AC contactor will increase the contact resistance between the moving and static contacts, resulting in excessively high temperature of the contact surface, and causing the surface contact to become a point contact, or even non-conduction. The reasons for this failure are:

  • There are oil stains, flower hairs, and foreign objects on the contacts.
  • Because of long-term use, the surface of the contact is oxidized.
  • Defects, burrs or metal swarf particles caused by arc ablation.
  • There is jamming in the moving part.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Dependable Performance
5
Cleoy
Avatar
10/12/2026 6:57 PM
After adding this contactor to our equipment, we found it easy to wire into the existing control panel. It switches our three-phase motor on and off as needed, and the coil voltage matches our setup. So far, it’s been working smoothly for our daily operations.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

ATO 3 pole AC magnetic contactor is used in 3 phase units. This contactor relay works between power source and high load electrical motor to balance changes in electrical frequency which may come from a power supply.

Specification

ModelATO-CJX2-F185
Rated Currentle max AC-3 (Ue≤440V)185A
le max AC-1 (θ≤40°C)275A
Coil Rated Voltage (Optional)110V AC, 220V AC, 380V AC
Contact Form3NO
Auxiliary Contact (Optional)2NO, 2NC, 1NO+1NC, 2NO+2NC, 1NC+3NO, 4NO, 4NC
Frequency50Hz/ 60Hz
Rated Insulated Voltage (Ui)1000V
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage440V
Conventional Thermal Current (θ≤40°C)275A
Operation FrequencyAC-1, AC-2, AC-31200 times/h
AC-4300A
Rated Power (AC-3)220/240V55kW
380/400V90kW
415V100kW
440V100kW
500V110kW
660/690V110kW
1000V100kW
Connection/ WiringNumber of Lines2
Line Size25x3mm2
Cable with Splicing150mm2
Cable with Connector150mm2
Screw Diameterφ8
Tightening Torque18N.m
Standards-CompliantIEC60947-4-1, GB14048.4, EN60947-4-1
Dimensions174 x 168.5 x 181mm
Weight9.5kg

Details

185 amp 3 phase AC Magnetic Contactor Details

Tips: Reasons for poor contact of the AC magnetic contactor

Poor contact of the AC contactor will increase the contact resistance between the moving and static contacts, resulting in excessively high temperature of the contact surface, and causing the surface contact to become a point contact, or even non-conduction. The reasons for this failure are:

  • There are oil stains, flower hairs, and foreign objects on the contacts.
  • Because of long-term use, the surface of the contact is oxidized.
  • Defects, burrs or metal swarf particles caused by arc ablation.
  • There is jamming in the moving part.