40 hp Horizontal Centrifugal Pump, Single Stage

$5,597.07
Centrifugal water pump horizontal centrifugal pump with horizontal struture, 40 hp motor power, 3 phase, maximum flow 32.5 m³/h (143 gpm), maximum head 127m (417ft) and same diameter of inlet and outlet 65mm (2-1/ 2 inch). Single end suction centrifugal pump with cheap price can be used for high-rise building pressurized water supply, HVAC & refrigeration water circulation, etc.
SKU: ATO-HCP-030kW
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Single stage centrifugal pump has optional input voltage AC 220V/ 230V/ 380V/ 400V/ 415V/ 460V to 480V, optional input frequency 50Hz/ 60Hz, 315mm nominal diameter of impeller, 0°, 90° and 180° installation angle of outlet.

Features:

  1. The centrifugal pump has the horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
  2. It is easy to install and maintain. No need to dismantle pipeline system, just lifting off the conjunction flat nut of vertical pump. Then all the rotor parts can be taken out.
  3. Horizontal centrifugal pump can be operating in series and parallel connection according to the requirements of flow and head.
  4. The installation angle of pump outlet can be 0°, 90° and 180° to meet different connection occasions.

Specification

  • Model: ATO-HCP-65-315
  • Power: 40 hp (30 kW)
  • Number of stages: Single stage
  • Input voltage: AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
  • Input frequency: 50Hz/ 60Hz
  • Inlet diameter: 65mm (2-1/ 2 inch)
  • Outlet diameter: 65mm (2-1/ 2 inch)
  • Flow (min. flow to max. flow): 17.5 m³/ h (77gpm), 25 m³/ h (110gpm), 32.5 m³/ h (143gpm)
  • Head (max. head to min. head): 127m (417ft), 125m (410ft), 122m (400ft)
  • Efficiency: 32%/ 40%/ 44%
  • Nominal diameter of impeller: 315mm
  • Size: 570*930*390mm
  • Weight: 320kg

Dimension (mm)

Boundary dimensionhHLaA
300570930125100
Base dimensionL1BIbh14-φd1
7003906202901004-φ20
Flange dimensionDD1n-φd
φ185φ1454-φ18

Horizontal centrifugal pump dimension

Tips: What is the Single-stage Centrifugal Pump?

The single-stage pump refers to a pump with only one impeller. The general single-stage pump has a high head of 125 meters (410ft). It has the advantages such as the simple structure, stable performance, high speed, small size, light weight, high efficiency, large flow, easy operation and maintenance and so on.

Classification of the single-stage centrifugal pump

According to the installation position of the motor, it is classified into: horizontal single-stage pump and vertical single-stage pump.
According to the flow pass of suction, it is classified into: single-stage single-suction centrifugal pump, single-stage double-suction centrifugal pump.

Phase3 phase
Input voltageAC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
Input frequency50Hz, 60Hz
Installation angle of outlet0°, 90° and 180°
Pump typeBooster pump
Number of stagesSingle stage
Motor typeY/ Y2 series motor
Motor speed2900rpm
Impeller material304/ 316 stainless steel
Seal material304 stainless steel, tungsten carbide, fluorine rubber
Inlet max. pressure1MPa (145 psi)
(NPSH)r2.3m
UsageWater, or liquids compatible with pump component materials.
1. The volume of solid particles should be less than 0.1% in unit volume, and the granularity should be less than 0.2mm.
2. The temperature should be lower than 60℃.
EnvironmentTemperature: <40℃, humidity: <95%, altitude<1000m
Warranty12 months

Different types of centrifugal pumps

This video explains different types of centrifugal pumps that can be selected according to one's own needs.

Principles and functionality explained

This video tells us what a centrifugal pump is and its working principle, and you will have a general understanding of it.

Components of centrifugal pumps

This video is an explanation of the components of a centrifugal pump, and we can learn the basic knowledge of the eight components of a centrifugal pump from it.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Single stage centrifugal pump has optional input voltage AC 220V/ 230V/ 380V/ 400V/ 415V/ 460V to 480V, optional input frequency 50Hz/ 60Hz, 315mm nominal diameter of impeller, 0°, 90° and 180° installation angle of outlet.

Features:

  1. The centrifugal pump has the horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
  2. It is easy to install and maintain. No need to dismantle pipeline system, just lifting off the conjunction flat nut of vertical pump. Then all the rotor parts can be taken out.
  3. Horizontal centrifugal pump can be operating in series and parallel connection according to the requirements of flow and head.
  4. The installation angle of pump outlet can be 0°, 90° and 180° to meet different connection occasions.

Specification

  • Model: ATO-HCP-65-315
  • Power: 40 hp (30 kW)
  • Number of stages: Single stage
  • Input voltage: AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
  • Input frequency: 50Hz/ 60Hz
  • Inlet diameter: 65mm (2-1/ 2 inch)
  • Outlet diameter: 65mm (2-1/ 2 inch)
  • Flow (min. flow to max. flow): 17.5 m³/ h (77gpm), 25 m³/ h (110gpm), 32.5 m³/ h (143gpm)
  • Head (max. head to min. head): 127m (417ft), 125m (410ft), 122m (400ft)
  • Efficiency: 32%/ 40%/ 44%
  • Nominal diameter of impeller: 315mm
  • Size: 570*930*390mm
  • Weight: 320kg

Dimension (mm)

Boundary dimensionhHLaA
300570930125100
Base dimensionL1BIbh14-φd1
7003906202901004-φ20
Flange dimensionDD1n-φd
φ185φ1454-φ18

Horizontal centrifugal pump dimension

Tips: What is the Single-stage Centrifugal Pump?

The single-stage pump refers to a pump with only one impeller. The general single-stage pump has a high head of 125 meters (410ft). It has the advantages such as the simple structure, stable performance, high speed, small size, light weight, high efficiency, large flow, easy operation and maintenance and so on.

Classification of the single-stage centrifugal pump

According to the installation position of the motor, it is classified into: horizontal single-stage pump and vertical single-stage pump.
According to the flow pass of suction, it is classified into: single-stage single-suction centrifugal pump, single-stage double-suction centrifugal pump.

Only registered users can write reviews