100 hp Horizontal Centrifugal Pump, Single Stage

$12,154.09
Good price centrifugal pump has 100 hp motor power, with horizontal structure. 3-phase centrifugal water pump with same diameter of inlet and outlet 80mm (3 inches), optional input voltage from AC 220V to 480V, input frequency 50Hz/ 60Hz for selection. Horizontal centrifugal pump can be used for high-rise building pressurized water supply, HVAC & refrigeration water circulation, etc.
SKU: ATO-HCP-075kW
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

Centrifugal water pump featuring maximum flow 130 m³/h (572 gpm), maximum head 132m (433ft) and 315mm nominal diameter of impeller. Single stage centrifugal water pump has advantages of stable operation, low noise, low failure rate, convenient maintenance, and less land occupation.

Features:

  1. The centrifugal pump has the horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
  2. It is easy to install and maintain. No need to dismantle pipeline system, just lifting off the conjunction flat nut of vertical pump. Then all the rotor parts can be taken out.
  3. Horizontal centrifugal pump can be operating in series and parallel connection according to the requirements of flow and head.
  4. The installation angle of pump outlet can be 0°, 90° and 180° to meet different connection occasions.

Specification

  • Model: ATO-HCP-80-315I
  • Power: 100 hp (75 kW)
  • Number of stages: Single stage
  • Input voltage: AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
  • Input frequency: 50Hz/ 60Hz
  • Inlet diameter: 80mm (3 inch)
  • Outlet diameter: 80mm (3 inch)
  • Flow (min. flow to max. flow): 70 m³/ h (308gpm), 100 m³/ h (440gpm), 130 m³/ h (572gpm)
  • Head (max. head to min. head): 132m (433ft), 125m (410ft), 114m (374ft)
  • Efficiency: 55%/ 66%/ 67%
  • Nominal diameter of impeller: 315mm
  • Size: 650*1210*560mm
  • Weight: 675kg

Dimension (mm)

Boundary dimensionhHLaA
325650121012585
Base dimensionL1BIbh14-φd1
9005608203601004-φ22
Flange dimensionDD1n-φd
φ200φ1608-φ18

Horizontal centrifugal pump dimension

Tips: Requirements for the Centrifugal Water Pump Installation Position.

The premise of continuous operation of the centrifugal pump is that the suction pipe must be filled with water before the pump start-up, otherwise the water will not be sucked up. In order to ensure that the suction pipe has no evacuation phenomenon due to pumping termination, it is necessary to solve the problem that the water suction pipe can be filled with water in both water pump stoppage and operation conditions. There are two installation position on site:

  1. The pump spindle is located below the water surface of the suction pool. This method is also called self-irrigation method. In other words, regardless of whether the water pump is running or not, the suction pipe is always under the action of the hydrostatic pressure of the water surface and the hydrostatic pressure of the water level of the pool to the center height H of the suction pipe, the suction pipe is always in a status of full of water.
    This method is quite common. The water pump can be started and stopped at any time requiring no measures.
  2. The water pump spindle is above the suction water level. When the water pump stops operating, the water in the suction pipe will flow back into the pool by the elevation difference. The suction pipe will be drained. If the water pump is started once again, it is required to fill in the suction pipe. However, such an operation is not practical. At this moment, it is only required to install one bottom valve on the end of the suction pipe(namely play the role of the  check valve), the emptying condition of the suction pipe can be stopped.
    In such installation means, one water pump can be connected on the water outlet pipe of the water pump for water filling. The air in the suction pipe and pump body can be eliminated through the vent valve on the pump body. Generally, if the bottom valve has no fault, the water pump can work normally.
Phase3 phase
Input voltageAC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
Input frequency50Hz, 60Hz
Installation angle of outlet0°, 90° and 180°
Pump typeBooster pump
Number of stagesSingle stage
Motor typeY/ Y2 series motor
Motor speed2900rpm
Impeller material304/ 316 stainless steel
Seal material304 stainless steel, tungsten carbide, fluorine rubber
Inlet max. pressure1MPa (145 psi)
(NPSH)r2.3m
UsageWater, or liquids compatible with pump component materials.
1. The volume of solid particles should be less than 0.1% in unit volume, and the granularity should be less than 0.2mm.
2. The temperature should be lower than 60℃.
EnvironmentTemperature: <40℃, humidity: <95%, altitude<1000m
Warranty12 months

Different types of centrifugal pumps

This video explains different types of centrifugal pumps that can be selected according to one's own needs.

Principles and functionality explained

This video tells us what a centrifugal pump is and its working principle, and you will have a general understanding of it.

Components of centrifugal pumps

This video is an explanation of the components of a centrifugal pump, and we can learn the basic knowledge of the eight components of a centrifugal pump from it.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Reliable, flexible
5
cxcx
Avatar
9/11/2025 12:08 AM
I bought the 100 hp horizontal centrifugal pump for our building’s water supply, and it works better than expected. Installation was simple with the compact design and aligned inlet/outlet. It delivers strong pressure and smooth performance, handling HVAC circulation with no issues. Reliable, flexible with voltage options, and a cost-effective choice for large-scale use.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Centrifugal water pump featuring maximum flow 130 m³/h (572 gpm), maximum head 132m (433ft) and 315mm nominal diameter of impeller. Single stage centrifugal water pump has advantages of stable operation, low noise, low failure rate, convenient maintenance, and less land occupation.

Features:

  1. The centrifugal pump has the horizontal structure. The diameter of the inlet and outlet are the same. If a protective cover is added, it can be used in the open air.
  2. It is easy to install and maintain. No need to dismantle pipeline system, just lifting off the conjunction flat nut of vertical pump. Then all the rotor parts can be taken out.
  3. Horizontal centrifugal pump can be operating in series and parallel connection according to the requirements of flow and head.
  4. The installation angle of pump outlet can be 0°, 90° and 180° to meet different connection occasions.

Specification

  • Model: ATO-HCP-80-315I
  • Power: 100 hp (75 kW)
  • Number of stages: Single stage
  • Input voltage: AC 220V, 230V, 240V, 380V, 400V, 415V, 440V, 460V, 480V
  • Input frequency: 50Hz/ 60Hz
  • Inlet diameter: 80mm (3 inch)
  • Outlet diameter: 80mm (3 inch)
  • Flow (min. flow to max. flow): 70 m³/ h (308gpm), 100 m³/ h (440gpm), 130 m³/ h (572gpm)
  • Head (max. head to min. head): 132m (433ft), 125m (410ft), 114m (374ft)
  • Efficiency: 55%/ 66%/ 67%
  • Nominal diameter of impeller: 315mm
  • Size: 650*1210*560mm
  • Weight: 675kg

Dimension (mm)

Boundary dimensionhHLaA
325650121012585
Base dimensionL1BIbh14-φd1
9005608203601004-φ22
Flange dimensionDD1n-φd
φ200φ1608-φ18

Horizontal centrifugal pump dimension

Tips: Requirements for the Centrifugal Water Pump Installation Position.

The premise of continuous operation of the centrifugal pump is that the suction pipe must be filled with water before the pump start-up, otherwise the water will not be sucked up. In order to ensure that the suction pipe has no evacuation phenomenon due to pumping termination, it is necessary to solve the problem that the water suction pipe can be filled with water in both water pump stoppage and operation conditions. There are two installation position on site:

  1. The pump spindle is located below the water surface of the suction pool. This method is also called self-irrigation method. In other words, regardless of whether the water pump is running or not, the suction pipe is always under the action of the hydrostatic pressure of the water surface and the hydrostatic pressure of the water level of the pool to the center height H of the suction pipe, the suction pipe is always in a status of full of water.
    This method is quite common. The water pump can be started and stopped at any time requiring no measures.
  2. The water pump spindle is above the suction water level. When the water pump stops operating, the water in the suction pipe will flow back into the pool by the elevation difference. The suction pipe will be drained. If the water pump is started once again, it is required to fill in the suction pipe. However, such an operation is not practical. At this moment, it is only required to install one bottom valve on the end of the suction pipe(namely play the role of the  check valve), the emptying condition of the suction pipe can be stopped.
    In such installation means, one water pump can be connected on the water outlet pipe of the water pump for water filling. The air in the suction pipe and pump body can be eliminated through the vent valve on the pump body. Generally, if the bottom valve has no fault, the water pump can work normally.
Product reviews
Reliable, flexible
5
cxcx
Avatar
9/11/2025 12:08 AM
I bought the 100 hp horizontal centrifugal pump for our building’s water supply, and it works better than expected. Installation was simple with the compact design and aligned inlet/outlet. It delivers strong pressure and smooth performance, handling HVAC circulation with no issues. Reliable, flexible with voltage options, and a cost-effective choice for large-scale use.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews