3 HP (2.2 kW) Magnetic Drive Pump

$3,073.57
3 hp magnetic drive water pump with ETFE wetted-end material and FKM O-ring material for sale. Magnetic drive centrifugal pump availble in flange connections. Mag drive pump able to handle many types of chemical and temperature up to 90 ℃. Magnetic drive pump is widely used in pharmaceutical industry.
SKU: ATO-MDP-3HP
*
*
*
Free Shipping
Delivery date: 10-12 days

A 3 hp magnetic drive pump refers to a type of industrial pump that utilizes magnetic coupling to transfer power from the motor to the pump impeller without a direct mechanical connection. Magnetic drive centrifugal pump adaptable to IEC standard motor. This type of pump is suitable forchemical industry and metal industry.

Features:

  • ETFE (carbon-fiber reinforced) wetted-end material.
  • Able to handle many types of chemical and temperature up to 90 ℃.
  • Available in flange connections.

Specification:

ModelATO-353PW-F
Specific Gravity1.2
Frequency50Hz, 60Hz
Rated Voltage3-phase 380V (please contact us for other voltages)
Pump performance at specific point (M-L/min)50Hz24-150
60Hz32-120
Motor Output3 HP (2.2 kW)
Flange Size32 mm (outlet); 32 mm (inlet)
Casing MaterialETFE
Shaft Materialceramic
Bearing Materialcarbon
O-ring MaterialFKM
Interface Modethread, flange
Net Weight46kg


Structure:

PW-F magnetic drive pump structure


Dimension (Unit: mm)

PW-F magnetic drive pump dimension

ModelWHLabcdef
352PW-F160242505.5222.513215513012078

Tips: How to Prime a Magnetic Drive Pump?

  • Ensure the magnetic drive pump is turned off and disconnected from the power source.
  • Open the suction valve on the inlet side of the pump.
  • Pour liquid into the inlet until the pump is filled.
  • Close the suction valve.
  • Turn on the pump and let it run for a few seconds to ensure that it is working properly.

It is important to never run a magnetic drive pump dry as this can cause damage to the pump. Always ensure that the pump is primed with the appropriate fluid before turning it on.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Good Quality Refined Design
5
eva
Avatar
12/4/2023 1:01 AM
It's a good little drive pump for the price, and It works perfectly when fitted with a ball valve to control flow. I'd purchase again.
Was this review helpful? Yes No (0/0)
The max RPM for the magnetic drive pump
5
Jefferson
Avatar
9/26/2024 12:41 AM
Hi, I was wondering what's the max RPM for the magnetic drive pump 350PW-F? May we know your available supply voltage, and frequency?
Was this review helpful? Yes No (0/0)
ATO Responded
Our pump needs to use VFD to adjust the speed. The normal adjustable frequency range is 30-60Hz. 30Hz speed is 1700RPM, 50Hz speed is 2900RPM, 60Hz is the maximum speed 3500RPM.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

A 3 hp magnetic drive pump refers to a type of industrial pump that utilizes magnetic coupling to transfer power from the motor to the pump impeller without a direct mechanical connection. Magnetic drive centrifugal pump adaptable to IEC standard motor. This type of pump is suitable forchemical industry and metal industry.

Features:

  • ETFE (carbon-fiber reinforced) wetted-end material.
  • Able to handle many types of chemical and temperature up to 90 ℃.
  • Available in flange connections.

Specification:

ModelATO-353PW-F
Specific Gravity1.2
Frequency50Hz, 60Hz
Rated Voltage3-phase 380V (please contact us for other voltages)
Pump performance at specific point (M-L/min)50Hz24-150
60Hz32-120
Motor Output3 HP (2.2 kW)
Flange Size32 mm (outlet); 32 mm (inlet)
Casing MaterialETFE
Shaft Materialceramic
Bearing Materialcarbon
O-ring MaterialFKM
Interface Modethread, flange
Net Weight46kg


Structure:

PW-F magnetic drive pump structure


Dimension (Unit: mm)

PW-F magnetic drive pump dimension

ModelWHLabcdef
352PW-F160242505.5222.513215513012078

Tips: How to Prime a Magnetic Drive Pump?

  • Ensure the magnetic drive pump is turned off and disconnected from the power source.
  • Open the suction valve on the inlet side of the pump.
  • Pour liquid into the inlet until the pump is filled.
  • Close the suction valve.
  • Turn on the pump and let it run for a few seconds to ensure that it is working properly.

It is important to never run a magnetic drive pump dry as this can cause damage to the pump. Always ensure that the pump is primed with the appropriate fluid before turning it on.

Product reviews
Good Quality Refined Design
5
eva
Avatar
12/4/2023 1:01 AM
It's a good little drive pump for the price, and It works perfectly when fitted with a ball valve to control flow. I'd purchase again.
Was this review helpful? Yes No (0/0)
The max RPM for the magnetic drive pump
5
Jefferson
Avatar
9/26/2024 12:41 AM
Hi, I was wondering what's the max RPM for the magnetic drive pump 350PW-F? May we know your available supply voltage, and frequency?
Was this review helpful? Yes No (0/0)
ATO Responded
Our pump needs to use VFD to adjust the speed. The normal adjustable frequency range is 30-60Hz. 30Hz speed is 1700RPM, 50Hz speed is 2900RPM, 60Hz is the maximum speed 3500RPM.
Only registered users can write reviews