15kVA 415V to 120V/240V Split Phase Transformer

$5,538.69
15kVA single phase to split phase distribution transformer step down 415V input voltage to 120V/240V output voltage, frequency 50/60Hz, winding material can choose aluminum or copper wire. Overload Capacity allows working at 1.2 times the rated load for up to 1 hour, making the single-phase transformer safe and reliable.
SKU: ATO-T-DGS15kVA
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

15 kVA isolation transformer is an automation single phase distribution transformer, convert primary voltage 415V to secondary voltage 120V/240V. Work efficiency up to 95%, low energy consumption and high efficiency make split-phase transformers an ideal choice.

15 kVA Single Phase to Split Phase Transformer Specifications

ModelATO-DGS15kVA
PhaseSingle phase to split phase
Capacity15 kVA
Primary Voltage1 Phase / 2 phase 110, 120, 208, 220, 230, 240, 380, 415, 440, 460, 480,
Secondary Voltage120V/240V AC(L1, L2, N, L+L=240V, L+N=120V)
Frequency50/60Hz
Winding MaterialAluminum/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength2000V AC/1 min
Noise≤35dB (1 meter)
Insulation GradeGrade B (130℃), Grade F (155℃), Grade H (180℃)
Cooling MethodNatural or air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 1 hour
Induced Overvoltage Withstand Test125Hz/800V/min
Transformation Ratio<3%
Air Carrying Current<6%
Impedance VoltageAbout 6%
Total Losses10%
CertificationCE, ISO
Temperature-15℃~+45℃
Humidity≤90%RH, without condensation
Altitude<2000m, non corrosive gas and conductive dust
Enclosure Protection GradeIP20
Warranty12 months
Weight of Aluminium Wire TransformerOpen type: 145kg
Protected type: 180kg
Weight of Copper Wire TransformerOpen type: 150kg
Protected type: 185kg

15 kVA Single Phase to Split Phase Transformer Schematic Diagram
Single phase to split phase transformer schematic diagram
15 kVA Single Phase to Split Transformer Dimension (Unit: mm)
Split phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=370*350*520mmOpen type: a*b*c=300*330*370mm
Mouting size: D*E=190*190mm (aperture: 20*10mm)Mouting size: 220*220mm (aperture: 20*10mm)
Protected type: A*B*C=420*610*610mmProtected type: A*B*C=420*610*610mm

Details

Single Phase Isolation Transformer Details

Tips: What is transformer load operation?

The load operation of the transformer refers to the working condition when the original winding is connected to the power supply voltage and the auxiliary winding is connected to the load. At this time, the secondary side of the transformer also has current flowing, and the access circuit of the original transformer increases correspondingly compared with no-load, and the secondary side voltage will be affected by the load and change.

Product reviews
Good quality transformer, recommend
5
Iris
Avatar
8/23/2026 7:30 PM
This transformer converts supply cleanly to 120/240V split‑phase. No noticeable voltage drop under rated load. Build quality looks heavy‑duty. Recommend for similar conversion jobs.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

15 kVA isolation transformer is an automation single phase distribution transformer, convert primary voltage 415V to secondary voltage 120V/240V. Work efficiency up to 95%, low energy consumption and high efficiency make split-phase transformers an ideal choice.

15 kVA Single Phase to Split Phase Transformer Specifications

ModelATO-DGS15kVA
PhaseSingle phase to split phase
Capacity15 kVA
Primary Voltage1 Phase / 2 phase 110, 120, 208, 220, 230, 240, 380, 415, 440, 460, 480,
Secondary Voltage120V/240V AC(L1, L2, N, L+L=240V, L+N=120V)
Frequency50/60Hz
Winding MaterialAluminum/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength2000V AC/1 min
Noise≤35dB (1 meter)
Insulation GradeGrade B (130℃), Grade F (155℃), Grade H (180℃)
Cooling MethodNatural or air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 1 hour
Induced Overvoltage Withstand Test125Hz/800V/min
Transformation Ratio<3%
Air Carrying Current<6%
Impedance VoltageAbout 6%
Total Losses10%
CertificationCE, ISO
Temperature-15℃~+45℃
Humidity≤90%RH, without condensation
Altitude<2000m, non corrosive gas and conductive dust
Enclosure Protection GradeIP20
Warranty12 months
Weight of Aluminium Wire TransformerOpen type: 145kg
Protected type: 180kg
Weight of Copper Wire TransformerOpen type: 150kg
Protected type: 185kg

15 kVA Single Phase to Split Phase Transformer Schematic Diagram
Single phase to split phase transformer schematic diagram
15 kVA Single Phase to Split Transformer Dimension (Unit: mm)
Split phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=370*350*520mmOpen type: a*b*c=300*330*370mm
Mouting size: D*E=190*190mm (aperture: 20*10mm)Mouting size: 220*220mm (aperture: 20*10mm)
Protected type: A*B*C=420*610*610mmProtected type: A*B*C=420*610*610mm

Details

Single Phase Isolation Transformer Details

Tips: What is transformer load operation?

The load operation of the transformer refers to the working condition when the original winding is connected to the power supply voltage and the auxiliary winding is connected to the load. At this time, the secondary side of the transformer also has current flowing, and the access circuit of the original transformer increases correspondingly compared with no-load, and the secondary side voltage will be affected by the load and change.

Product reviews
Good quality transformer, recommend
5
Iris
Avatar
8/23/2026 7:30 PM
This transformer converts supply cleanly to 120/240V split‑phase. No noticeable voltage drop under rated load. Build quality looks heavy‑duty. Recommend for similar conversion jobs.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews