1500A DC Contactor, 12V/24V/48V

$233.15
The coil voltage of this 1500A contactor is 12V DC contactor, 24V DC contactor, 48V DC contactor, etc. This DC contactor with a large current of 1500A is made of selected thermosetting BMC material and has no burning points. Wear-resistant, non-breaking and stable in performance.
SKU: ATO-DCCON-C1500
*
Free Shipping
Delivery date: 2-12 days

DC contactor provides high current of 1500A. The 1500A DC contactor has 12V, 24V, 48V and high voltage dc contactor, such has 120V, 150V, 220V. The DC contactor is not only made of carefully selected BMC thermoset material, wear-resistant, damage-free and stable, but also has quality and after-sales guaranteed.

Features

  • 1500A DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 1500 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • Single coil 1500A DC contactor are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJ1500A
Contact FormNormally open
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V, 220V
Contact Rated Voltage (DC V)≤80V
Contact 48V Circuit Rated Load Current (DC-1)1500A
Main Contact Contact Voltage Drop under 100A Load≯80mV
Cooling pull-in voltage (V), (20±5)℃≯70%
Cooling Release Operating Voltage (V), (20±5)℃≯40%,≮5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time30ms
Power off Release Time15ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)3000A/5ms at 48V DC
Coil Power Consumption (W)Start: 140-190, Hold: 9-18
Coil Temperature Rise (K)≤50
Terminal Temperature Rise (K)≤65
Electrical Life10000times
Mechanical Life200,000 times
Work SpecificationsContinuous
Contact MaterialSilver alloy
Load Terminal Type2-M12 screw
Coil Terminal TypeM4 screw
Auxiliary Contact Rated Load (Optional)2A/48VDC, 5A/24VDC
Testing Agency CertificationCE, FCC, RoHS


Load Characteristic Curve

1500A DC contactor estimated electric life

1500A DC contactor estimated contact performance

Installation Dimension Diagram

1500A DC contactor installation dimension drawing

Wiring Diagram & Coil Temperature Rise Curve Graph

1500A DC contactor wiring diagram

One way is normally open (SPST 1NO)
1 and 2 are contact terminals
A1 and A2 are coil terminals
L1 is the take-off winding L2 is the holding winding

1500A DC contactor coil temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯30 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: DC contactor wiring method

  1. The DC contactor's coil is connected to the control circuit and is used to control the motor in the circuit part (use small to control large).
  2. The auxiliary contact represents the normally open contact of the contactor, which is opened when not powered and closed after powered on. It is used to control the self-locking of the circuit or be connected in parallel to the start button to achieve continuous operation.
  3. Both ends of the DC contactor'scoil are connected to the control circuit, the normally open contact is connected to the anode, and the normally closed contact is connected to the load.
  4. When the coil of DC contactor is activated, the normally open contact opens, the normally closed contact closes, and the load is energized; when the control circuit is deenergized, the normally open contact closes, the normally closed contact opens, and the load is deenergized.The above information is based on the general wiring method of DC contactors.
  5. Specific operations need to be appropriately adjusted according to the actual equipment model and wiring diagram.
Product reviews
Information Needed
5
Schulich
Avatar
1/6/2026 11:34 PM
I'm planning to buy a DC contactor, but the weight of the device is a concern, so I'd like to know more about it before placing an order.
Was this review helpful? Yes No (0/0)
ATO Responded
This DC contactor is for 24V coils. This unit, ATO-DCCON-C1500, weighs 2800g net per unit.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

DC contactor provides high current of 1500A. The 1500A DC contactor has 12V, 24V, 48V and high voltage dc contactor, such has 120V, 150V, 220V. The DC contactor is not only made of carefully selected BMC thermoset material, wear-resistant, damage-free and stable, but also has quality and after-sales guaranteed.

Features

  • 1500A DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 1500 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • Single coil 1500A DC contactor are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJ1500A
Contact FormNormally open
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V, 220V
Contact Rated Voltage (DC V)≤80V
Contact 48V Circuit Rated Load Current (DC-1)1500A
Main Contact Contact Voltage Drop under 100A Load≯80mV
Cooling pull-in voltage (V), (20±5)℃≯70%
Cooling Release Operating Voltage (V), (20±5)℃≯40%,≮5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time30ms
Power off Release Time15ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)3000A/5ms at 48V DC
Coil Power Consumption (W)Start: 140-190, Hold: 9-18
Coil Temperature Rise (K)≤50
Terminal Temperature Rise (K)≤65
Electrical Life10000times
Mechanical Life200,000 times
Work SpecificationsContinuous
Contact MaterialSilver alloy
Load Terminal Type2-M12 screw
Coil Terminal TypeM4 screw
Auxiliary Contact Rated Load (Optional)2A/48VDC, 5A/24VDC
Testing Agency CertificationCE, FCC, RoHS


Load Characteristic Curve

1500A DC contactor estimated electric life

1500A DC contactor estimated contact performance

Installation Dimension Diagram

1500A DC contactor installation dimension drawing

Wiring Diagram & Coil Temperature Rise Curve Graph

1500A DC contactor wiring diagram

One way is normally open (SPST 1NO)
1 and 2 are contact terminals
A1 and A2 are coil terminals
L1 is the take-off winding L2 is the holding winding

1500A DC contactor coil temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯30 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: DC contactor wiring method

  1. The DC contactor's coil is connected to the control circuit and is used to control the motor in the circuit part (use small to control large).
  2. The auxiliary contact represents the normally open contact of the contactor, which is opened when not powered and closed after powered on. It is used to control the self-locking of the circuit or be connected in parallel to the start button to achieve continuous operation.
  3. Both ends of the DC contactor'scoil are connected to the control circuit, the normally open contact is connected to the anode, and the normally closed contact is connected to the load.
  4. When the coil of DC contactor is activated, the normally open contact opens, the normally closed contact closes, and the load is energized; when the control circuit is deenergized, the normally open contact closes, the normally closed contact opens, and the load is deenergized.The above information is based on the general wiring method of DC contactors.
  5. Specific operations need to be appropriately adjusted according to the actual equipment model and wiring diagram.
Product reviews
Information Needed
5
Schulich
Avatar
1/6/2026 11:34 PM
I'm planning to buy a DC contactor, but the weight of the device is a concern, so I'd like to know more about it before placing an order.
Was this review helpful? Yes No (0/0)
ATO Responded
This DC contactor is for 24V coils. This unit, ATO-DCCON-C1500, weighs 2800g net per unit.
Only registered users can write reviews
Customers who bought this item also bought

200A DC Contactor, 12V/24V/48V

ATO-DCCON-C200
$121.65
This 200 amps contactor is available in coil voltage 12V, 24V, 48V, continuous operating duty, normally open (NO) or normally closed (NC) contact form, high quality DC contactor with high-performance quality, low cost and manufacturer direct sale.