300A DC Contactor, 12V/24V/48V/220V

$145.36
300A DC contactor with high-performance quality, contact form can be selected as normally open or normally closed. This 300 amps contactor is available in coil voltage 12V, 24V, 48V, 220V, with low cost and manufacturer direct sale.
SKU: ATO-DCCON-C300
*
*
Free Shipping
Delivery date: 2-12 days

High performance 300A DC contactor with normally open or normally closed contact options. This DC contactor is available at low cost direct from the manufacturer and is available in coil voltages of 12V, 24V, 48V and 220V. Single coil 300A DC contactor is suitable for switch control of system circuits such as electric toy cars, battery cars, cleaning cars, automobile air conditioners, communication power supplies, and automobile air conditioners.

Features

  • 300A DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 300 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 300A DC contactor are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJ300A-DATO-SZJ300A
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V , 150V, 220V12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤80V
Contact 48V Circuit Rated Load Current (DC-1)300A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%≤40%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms15ms
Power-off Release Time20ms10ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)1000A/5ms at 48V DC
Coil Power Consumption (W)7-15Start: 120-170, Hold: 4-10
Coil Temperature Rise (K)≤80≤40
Terminal Temperature Rise (K)≤65
Electrical Life20000times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver alloy
Load Terminal TypeM8 screw
Coil Terminal TypeM4 screw
Auxiliary Contact Rated Load (Optional)2A/48VDC, 5A/24VDC, one on and one-off2A/48VDC, 5A/24VDC
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

300A DC contactor estimated electric life300A DC contactor estimated contact performance


Installation Dimension Diagram


300A DC contactor m installation dimension drawing

300A DC contactor x installation dimension drawing

300A DC contactor installation dimension drawing


SZJ300A-D Wiring Diagram & Coil Temperature Rise Curve Graph


Normally closed wiring diagram

One way is normally closed (SPST 1NC)
1 and 2 are contact terminals
A1 and A2 are coil terminals

300A DC contactor szj-d temperature rise curve graph

SZJ300A Wiring Diagram & Coil temperature Rise Curve Graph


300A DC contactor wiring diagram

One way is normally open (SPST 1NO)

1 and 2 are contact terminals
A1 and A2 are coil terminals
L1 is the take-off winding L2 is the holding winding

300A DC contactor szj coil temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯9.0 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: The difference between DC contactor's single coil and double coil

  • The starting power of the DC contactor's single coil is as small as the holding power, and the pull-in voltage range is wider. For example, a DC contactor with a 48V coil can pull in normally at a voltage of 41V, but the temperature rise is faster than that of a double coil.
  • The dual-coil coil of DC contactor has a large starting power, a small holding power, and a narrower voltage pull-in range. For example, a DC power contactor with a 48V coil requires a minimum pull-in voltage of 43V, but the temperature rise is slower than that of a single coil.

In this video we will try to clear the confusion many people have between relays and contactors by showing you how to tell the difference based on five criteria: Definition, Capacity, Structure, Contacts and Applications.

Product reviews
Reliable DC contactor
5
Narlix
Avatar
1/16/2025 6:05 PM
In actual applications, I found that the 300A rated current handling capacity allows this contactor to easily handle high-load scenarios. Whether it is starting large motors or controlling heavy machinery and equipment, it can work stably without fear of current shock.
Was this review helpful? Yes No (0/0)
This contactor works great so far
5
Arden
Avatar
7/27/2026 7:01 PM
Installed this contactor on my battery system. It works smoothly and feels very solid. Good build quality and reliable performance.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

High performance 300A DC contactor with normally open or normally closed contact options. This DC contactor is available at low cost direct from the manufacturer and is available in coil voltages of 12V, 24V, 48V and 220V. Single coil 300A DC contactor is suitable for switch control of system circuits such as electric toy cars, battery cars, cleaning cars, automobile air conditioners, communication power supplies, and automobile air conditioners.

Features

  • 300A DC contactor has the characteristics of small size, large load capacity, long service life and simple maintenance, and is very popular among users.
  • 300 amps contactor complies with the requirements of the ministry standards JB2286-78, JB3974-85, YD/585-92, YD/T512-92. It has been tested in the factory and by relevant testing units and meets the requirements of the ministry standards. It has been used by users for many years to satisfy users to the maximum extent. Needed, reliable quality.
  • 300A DC contactor are suitable for electric forklifts, battery trucks, tractors, excavators, brick making machines, cleaning vehicles, automotive air conditioners, communication power supplies, switch control of electronic control circuits of uninterruptible power supplies, electroplating power supplies and other systems.

Specifications

ModelATO-SZJ300A-DATO-SZJ300A
Contact FormNormally Closed (NC)Normally Open (NO)
Coil Rated Voltage (DC V)12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V , 150V, 220V12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact Rated Voltage (DC V)≤80V
Contact 48V Circuit Rated Load Current (DC-1)300A
Main Contact Contact Voltage Drop Under 100A Load≤80mV
Cooling pull-in voltage (V), (20±5)℃≤70%
Cooling release operating voltage (V), (20±5)℃≤35%, ≥5%≤40%, ≥5%
40℃ Coil Operating Voltage Range0.8-1.2Us
Power-on Action Time10ms15ms
Power-off Release Time20ms10ms
Maximum Bounce Time of Contact Connection10ms
Maximum Bounce Time of Contact Disconnection3ms
Insulation Resistance20MΩ
Dielectric Strength50Hz/60Hz 1000VAC 1minute
Maximum Breaking Capacity of Main Contact (Power on for 5ms)1000A/5ms at 48V DC
Coil Power Consumption (W)7-15Start: 120-170, Hold: 4-10
Coil Temperature Rise (K)≤80≤40
Terminal Temperature Rise (K)≤65
Electrical Life20000times
Mechanical Life300,000 times
Work SpecificationsContinuous
Contact MaterialSilver alloy
Load Terminal TypeM8 screw
Coil Terminal TypeM4 screw
Auxiliary Contact Rated Load (Optional)2A/48VDC, 5A/24VDC, one on and one-off2A/48VDC, 5A/24VDC
Testing Agency CertificationCCC, CE, FCC, RoHS


Load Characteristic Curve

300A DC contactor estimated electric life300A DC contactor estimated contact performance


Installation Dimension Diagram


300A DC contactor m installation dimension drawing

300A DC contactor x installation dimension drawing

300A DC contactor installation dimension drawing


SZJ300A-D Wiring Diagram & Coil Temperature Rise Curve Graph


Normally closed wiring diagram

One way is normally closed (SPST 1NC)
1 and 2 are contact terminals
A1 and A2 are coil terminals

300A DC contactor szj-d temperature rise curve graph

SZJ300A Wiring Diagram & Coil temperature Rise Curve Graph


300A DC contactor wiring diagram

One way is normally open (SPST 1NO)

1 and 2 are contact terminals
A1 and A2 are coil terminals
L1 is the take-off winding L2 is the holding winding

300A DC contactor szj coil temperature rise curve graph

Mechanical Capabilities and Usage Environment

Contact Terminal M8 Tightening Torque (Nm)≯9.0 is appropriate
Coil Lead-out M4 Tightening Torque (Nm)≯1.2 is appropriate
Ambient Temperature-25~+70℃
Relative Humidity+20℃ 98%
Vibration Frequency at Fixed Location3G, 1~50Hz, amplitude 0.5mm
Impact(60~100) times/min, acceleration ≤4g
Altitude2000 meters
Installation DirectionArbitrary
Protection LevelIP40 (equivalent to IEC60947)

Tips: The difference between DC contactor's single coil and double coil

  • The starting power of the DC contactor's single coil is as small as the holding power, and the pull-in voltage range is wider. For example, a DC contactor with a 48V coil can pull in normally at a voltage of 41V, but the temperature rise is faster than that of a double coil.
  • The dual-coil coil of DC contactor has a large starting power, a small holding power, and a narrower voltage pull-in range. For example, a DC power contactor with a 48V coil requires a minimum pull-in voltage of 43V, but the temperature rise is slower than that of a single coil.
Product reviews
Reliable DC contactor
5
Narlix
Avatar
1/16/2025 6:05 PM
In actual applications, I found that the 300A rated current handling capacity allows this contactor to easily handle high-load scenarios. Whether it is starting large motors or controlling heavy machinery and equipment, it can work stably without fear of current shock.
Was this review helpful? Yes No (0/0)
This contactor works great so far
5
Arden
Avatar
7/27/2026 7:01 PM
Installed this contactor on my battery system. It works smoothly and feels very solid. Good build quality and reliable performance.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews