15 HP 12 Ton Air Cooled Industrial Water Chiller

$14,812.31
15 HP 12 ton air cooled industrial water chiller controlled by microcomputer system, which controls the water temperature within 3℃ to 45℃ precisely. It is built in world famous brand fully enclosed scroll refrigeration compressors and evaporator combination, supercooling, quiet and energy-saving.
SKU: ATO-IWC-15HP
*
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 8-12 days

12 ton cooling capacity water chiller for industrial injection machine, equipped with 3 compressors and total power of 15 HP, air-cooled finned type condenser, R22 or R407C refrigerant used as a standard for efficient cooling. Working frequency of 50Hz/60Hz and operates at 3 phase 380V/ 400V/ 480V AC power supply.

Features

  • Adopted high-quality compressors and pumps to ensure safe & quiet running, power saving and durable service life.
  • Employed microcomputer with easy operation which can control the temperature within 3℃ to 45℃ precisely.
  • Unique design for condenser and heat-dispersion unit results in excellent heat-exchange effect.
  • Equipped with electrical current overload protection, high & low-pressure switch, and electrical timer delay safety device. It will alarm to display faulty when any malfunction occurs.
  • Built-in stainless steel insulated water tank, durable and easy to clean.
  • Complete safety devices including power reverse phase, power short phase and anti-freeze protection.
  • Ultra low-temperature type of chiller can reach below -60℃.

Parameter

ModelATO-LC15A
Cooling Capacity12 ton
Number of Compressors3
Compressor Total Power15 HP
RefrigerantR22 / R407C (Optional)
Evaporator TypeSpiral type / Tube-in-shell type (Optional)
Condenser TypeFinned
Cooling TypeAir-cooled
Number of Fans2
Single Fan power0.45kW
Number of Cooling Water Inlet/Outlet1 group
Cooling Water Inlet/Outlet SizeDN50
Water Tank Capacity200L
Pump Power2 HP
Pump Flow360L/min
Pump Lifts15M
Power Supply3-phase 4-wire AC 208V/60Hz, 220V/60Hz, 240V/60Hz, 380V/50Hz, 400V/50Hz, 415V/50Hz, 480V/60Hz (Optional)
Control Voltage1-phase AC 220V (L+N)
Total Power13.7kW
Wires Specifications4x10mm2
Chilled Water Temperature Range5℃~35℃
Inlet/Outlet Water Temperature Difference3℃~8℃
Condensation Temperature≤ 35℃
CertificationCE
DimensionL*W*H=1680*830*1670mm
Net Weight / Gross Weight650kg / 720kg


Shipping Way of ATO Water Chiller

Just confirm the shipping way by email when place your order.

1. Ship by Air: The compressed refrigerant inside the chiller is a dangerous item with the possibility of explosion, so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shipping way. After the machine arrives at your destination, you need to add refrigerant by local professionals, the process is as simple as adding refrigerant for ordinary air conditioners). Delivery time is about 15-30 days.

2. Ship by Sea: The transportation time is longer (about 40-55 days), and there is no need to add refrigerant after the equipment arrives at the destination.

Note:

1. The "cooling capacity" is tested based on the inlet and outlet water temperature of freezing is 12℃/7℃, and the inlet and outlet water temperature of cooling is 30℃/35℃.

2. Conversion of units: 1 ton cooling capacity=3024kcal/hr, 1kcal/hr=3.969BTU/hr, 1HP=0.735kW=2580kcal/hr

Evaporator Types

Water chiller evaporator types

Type 1: Water Tank with Coil

  • Integrated Design: The industrial water chiller features a built-in open-top water tank with an integrated coil, providing a compact and self-contained cooling solution.
  • Sealed Circulation: The water circuit operates in a sealed loop, ensuring stable performance and preventing contamination.
  • Direct Connection: The air-cooled water chiller supports direct connection to equipment requiring cooling, with no external tank needed.

Type 2: Shell and Tube

  • Tankless Configuration: This water chiller is designed without an internal water tank and relies on an external open water tank for operation.
  • Application: Specifically suitable for cooling external open water tanks, pools, or reservoirs in industrial and commercial applications.

Water Chiller Structure Diagram

water chiller structure diagram

①Compressor②High-pressure gauge③Condenser④Dry filter
⑤Expansion valve⑥Water supply⑦Evaporator⑧Low-pressure gauge
⑨Water tank⑩Drain⑪Refrigerated water⑫Pump


Tips: reasons for water chiller high-pressure

1. High cooling water temperature leads to poor condensation effect. The rated working condition of cooling water required by the chiller is 30 ~ 35 ℃, high water temperature, and poor heat dissipation will inevitably lead to high condensation pressure, which often occurs in high-temperature season.

2. The cooling water flow is insufficient to reach the rated water flow. The main performance is that the pressure difference between the inlet and outlet water of the unit becomes smaller (compared with the pressure difference at the beginning of the system operation), and the temperature difference becomes larger. The reason for insufficient water flow is: a. The lack of water or air in the system. The solution is to install an exhaust valve at the height of the pipeline for exhaust. b. The pipeline filter is blocked or too fine, and the water permeability is limited. The solution is to choose a suitable filter and clean the filter regularly.

3. Too much refrigerant charge. This kind of situation generally occurs after maintenance, which shows that the suction and discharge pressure and balance pressure are high, and the running current of the compressor is also high. The air shall be discharged under rated working conditions according to the suction and discharge pressure, balance pressure and operating current until normal.

4. The refrigerant is mixed with air, nitrogen and other non-condensable gases. This kind of situation usually occurs after maintenance, and the vacuuming is not complete. It can only be drained, vacuumized and filled with refrigerant again.

How to Fill an Industrial Water Chiller with Refrigeran?

This video shows how to fill an industrial water chiller with refrigerant. The steps for filling a chiller with refrigerant are similar to those for filling an air conditioner with refrigerant, first drain the air and then fill the equipment with refrigerant.

Product reviews
12 ton water chiller works as expected
5
Farrah
Avatar
3/11/2022 2:02 AM
15 HP 12 ton air cooled industrial water chiller arrived in one piece and works as expected. The digital readout on front makes it easy to see water temps. Big plus is can adjust it on main panel.
Was this review helpful? Yes No (0/0)
Exactly what I needed
5
Alston
Avatar
3/18/2022 12:06 AM
Just what I expected a quality piece of equipment. I've been using this water chiller for a few weeks now and could not be happier with it. I would highly recommend this product!!
Was this review helpful? Yes No (0/0)
Superb 12 ton industrial water chiller
5
Keran
Avatar
7/21/2022 3:12 AM
This 12 ton industrial water chiller is really great. I marveled at its performance. I have used this water chiller in my factory for two months and haven't found any problems so far.
Was this review helpful? Yes No (0/0)
Pleased with the performance of this water chiller
5
Visonelet
Avatar
11/16/2022 10:43 PM
I am very pleased with the performance of this 15 hp air cooled water chiller. It hasn't given us any problems so far. I Hopefully it will continue for several years.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

12 ton cooling capacity water chiller for industrial injection machine, equipped with 3 compressors and total power of 15 HP, air-cooled finned type condenser, R22 or R407C refrigerant used as a standard for efficient cooling. Working frequency of 50Hz/60Hz and operates at 3 phase 380V/ 400V/ 480V AC power supply.

Features

  • Adopted high-quality compressors and pumps to ensure safe & quiet running, power saving and durable service life.
  • Employed microcomputer with easy operation which can control the temperature within 3℃ to 45℃ precisely.
  • Unique design for condenser and heat-dispersion unit results in excellent heat-exchange effect.
  • Equipped with electrical current overload protection, high & low-pressure switch, and electrical timer delay safety device. It will alarm to display faulty when any malfunction occurs.
  • Built-in stainless steel insulated water tank, durable and easy to clean.
  • Complete safety devices including power reverse phase, power short phase and anti-freeze protection.
  • Ultra low-temperature type of chiller can reach below -60℃.

Parameter

ModelATO-LC15A
Cooling Capacity12 ton
Number of Compressors3
Compressor Total Power15 HP
RefrigerantR22 / R407C (Optional)
Evaporator TypeSpiral type / Tube-in-shell type (Optional)
Condenser TypeFinned
Cooling TypeAir-cooled
Number of Fans2
Single Fan power0.45kW
Number of Cooling Water Inlet/Outlet1 group
Cooling Water Inlet/Outlet SizeDN50
Water Tank Capacity200L
Pump Power2 HP
Pump Flow360L/min
Pump Lifts15M
Power Supply3-phase 4-wire AC 208V/60Hz, 220V/60Hz, 240V/60Hz, 380V/50Hz, 400V/50Hz, 415V/50Hz, 480V/60Hz (Optional)
Control Voltage1-phase AC 220V (L+N)
Total Power13.7kW
Wires Specifications4x10mm2
Chilled Water Temperature Range5℃~35℃
Inlet/Outlet Water Temperature Difference3℃~8℃
Condensation Temperature≤ 35℃
CertificationCE
DimensionL*W*H=1680*830*1670mm
Net Weight / Gross Weight650kg / 720kg


Shipping Way of ATO Water Chiller

Just confirm the shipping way by email when place your order.

1. Ship by Air: The compressed refrigerant inside the chiller is a dangerous item with the possibility of explosion, so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shipping way. After the machine arrives at your destination, you need to add refrigerant by local professionals, the process is as simple as adding refrigerant for ordinary air conditioners). Delivery time is about 15-30 days.

2. Ship by Sea: The transportation time is longer (about 40-55 days), and there is no need to add refrigerant after the equipment arrives at the destination.

Note:

1. The "cooling capacity" is tested based on the inlet and outlet water temperature of freezing is 12℃/7℃, and the inlet and outlet water temperature of cooling is 30℃/35℃.

2. Conversion of units: 1 ton cooling capacity=3024kcal/hr, 1kcal/hr=3.969BTU/hr, 1HP=0.735kW=2580kcal/hr

Evaporator Types

Water chiller evaporator types

Type 1: Water Tank with Coil

  • Integrated Design: The industrial water chiller features a built-in open-top water tank with an integrated coil, providing a compact and self-contained cooling solution.
  • Sealed Circulation: The water circuit operates in a sealed loop, ensuring stable performance and preventing contamination.
  • Direct Connection: The air-cooled water chiller supports direct connection to equipment requiring cooling, with no external tank needed.

Type 2: Shell and Tube

  • Tankless Configuration: This water chiller is designed without an internal water tank and relies on an external open water tank for operation.
  • Application: Specifically suitable for cooling external open water tanks, pools, or reservoirs in industrial and commercial applications.

Water Chiller Structure Diagram

water chiller structure diagram

①Compressor②High-pressure gauge③Condenser④Dry filter
⑤Expansion valve⑥Water supply⑦Evaporator⑧Low-pressure gauge
⑨Water tank⑩Drain⑪Refrigerated water⑫Pump


Tips: reasons for water chiller high-pressure

1. High cooling water temperature leads to poor condensation effect. The rated working condition of cooling water required by the chiller is 30 ~ 35 ℃, high water temperature, and poor heat dissipation will inevitably lead to high condensation pressure, which often occurs in high-temperature season.

2. The cooling water flow is insufficient to reach the rated water flow. The main performance is that the pressure difference between the inlet and outlet water of the unit becomes smaller (compared with the pressure difference at the beginning of the system operation), and the temperature difference becomes larger. The reason for insufficient water flow is: a. The lack of water or air in the system. The solution is to install an exhaust valve at the height of the pipeline for exhaust. b. The pipeline filter is blocked or too fine, and the water permeability is limited. The solution is to choose a suitable filter and clean the filter regularly.

3. Too much refrigerant charge. This kind of situation generally occurs after maintenance, which shows that the suction and discharge pressure and balance pressure are high, and the running current of the compressor is also high. The air shall be discharged under rated working conditions according to the suction and discharge pressure, balance pressure and operating current until normal.

4. The refrigerant is mixed with air, nitrogen and other non-condensable gases. This kind of situation usually occurs after maintenance, and the vacuuming is not complete. It can only be drained, vacuumized and filled with refrigerant again.

Product reviews
12 ton water chiller works as expected
5
Farrah
Avatar
3/11/2022 2:02 AM
15 HP 12 ton air cooled industrial water chiller arrived in one piece and works as expected. The digital readout on front makes it easy to see water temps. Big plus is can adjust it on main panel.
Was this review helpful? Yes No (0/0)
Exactly what I needed
5
Alston
Avatar
3/18/2022 12:06 AM
Just what I expected a quality piece of equipment. I've been using this water chiller for a few weeks now and could not be happier with it. I would highly recommend this product!!
Was this review helpful? Yes No (0/0)
Superb 12 ton industrial water chiller
5
Keran
Avatar
7/21/2022 3:12 AM
This 12 ton industrial water chiller is really great. I marveled at its performance. I have used this water chiller in my factory for two months and haven't found any problems so far.
Was this review helpful? Yes No (0/0)
Pleased with the performance of this water chiller
5
Visonelet
Avatar
11/16/2022 10:43 PM
I am very pleased with the performance of this 15 hp air cooled water chiller. It hasn't given us any problems so far. I Hopefully it will continue for several years.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews