High efficiency hydraulic tandem gear pump for sale. Displacement 11/12/13/14 GPM, rated pressure 3000 psi, maximum 3600 psi, rated speed 1800 rpm, maximum 3500 rpm, optional clockwise or counterclockwise rotary. The hydraulic double gear pump has 2 stage pumps, applications include industrial/agricultural/commercial machinery, construction machinery, environmental protection equipment, and chemical equipment, etc.
Specification
| Model | ATO-HGP-33A | |||||||||
| Displacement | mL/ rev | |||||||||
| 6 | 8.4 | 11 | 14.3 | 16.5 | 19.2 | 23 | 25 | 28 | 30 | |
| Max. GPM (Gallon/min) | ||||||||||
| 2.9 | 4.0 | 5.2 | 6.8 | 7.8 | 9.1 | 10.9 | 11.9 | 13.3 | 14.3 | |
| Rated Speed | 1800 rpm | 1800 rpm | 1800 rpm | 1800 rpm | 1800 rpm | 1800 rpm | 1800 rpm | 1800 rpm | 1800 rpm | 1800 rpm |
| Max. Speed | 3500 rpm | 3500 rpm | 3000 rpm | 3000 rpm | 3000 rpm | 3000 rpm | 3000 rpm | 3000 rpm | 3000 rpm | 3000 rpm |
| Min. Speed | 700 rpm | 700 rpm | 600 rpm | 600 rpm | 500 rpm | 500 rpm | 500 rpm | 500 rpm | 500 rpm | 500 rpm |
| Rated Pressure | 3000 psi (21 MPa) | |||||||||
| Max. Pressure | 3600 psi (25 MPa) | |||||||||
| Volumetric Efficiency | 90% | 90% | 93% | 93% | 93% | 93% | 93% | 93% | 93% | 93% |
| Mechanical Efficiency | 88% | 88% | 88% | 88% | 88% | 88% | 88% | 90% | 90% | 90% |
| Inlet Thread | 3/4 inch | 1 inch | ||||||||
| Outlet Thread | 1/2 inch | 3/4 inch | ||||||||
| Rotary Direction | clockwise, counterclockwise | |||||||||
| Working Temperature | -20℃~70℃ | |||||||||
| Shaft Extension | φ 17.48mm flat key | |||||||||
| Mounting Flange | SAE 2-bolt | |||||||||
Note:
- Please use ATO gear pump with sufficient oil, otherwise there is a risk of burnout!
- Calculate the actual displacement value according to the formula: Gallon/min=displacement (ml/rev)*rated speed 1800rpm/3785.41L (speed variation range 500rpm-3000rpm).
Features
- Hydraulic tandem gear pump uses high-strength aluminum alloy shell and alloy steel hard gear transmission, which is light in weight and stable in transmission.
- Installation of the hydraulic tandem gear pump is SAE 2-bolt standard flange. Input shaft connection is woodruff key. Connection type of the oil inlet and outlet ports is thread.
- Hydraulic tandem gear pump has an automatic compensation mechanism for axial and radial clearances, which enables the oil pump to maintain high volumetric efficiency and high mechanical efficiency for a long time.
- Hydraulic tandem gear pump uses SP gears, with small fluctuation, high pressure, low noise and stable performance.
- Hydraulic tandem gear pump uses composite material bearings and high-performance sealing elements, has a small starting torque and good tightness, and can work efficiently under harsh working conditions.
- The front and rear gear pumps work independently of each other, and any combination of displacements can be customized according to requirements.
11/13/18/20 GPM Hydraulic Tandem Gear Pump Dimensions Diagram (Unit: mm)

| Front Pump Displacement (Max. GPM) | Rear Pump Displacement (Max. GPM) | A (mm) | B (mm) | C (mm) | Weight (kg) |
| 14.3 | 2.9 | 214.5 | 70.0 | 90 | 5.2 |
| 13.3 | 2.9 | 210.5 | 68.0 | 88 | 5.1 |
| 11.9 | 2.9 | 206.5 | 66.0 | 86 | 5.0 |
| 14.3 | 4.0 | 217.5 | 70.0 | 91 | 5.3 |
| 13.3 | 4.0 | 213.5 | 68.0 | 89 | 5.2 |
| 11.9 | 4.0 | 209.5 | 66.0 | 87 | 5.1 |
| 14.3 | 5.2 | 223.5 | 70.0 | 93 | 5.4 |
| 13.3 | 5.2 | 219.5 | 68.0 | 91 | 5.3 |
| 11.9 | 5.2 | 215.5 | 66.0 | 89 | 5.2 |
| 2.9 | 2.9 | 174.5 | 50.0 | 70 | 4.1 |
| 4.0 | 4.0 | 180.5 | 51.5 | 73 | 4.3 |
| 5.2 | 5.2 | 191.5 | 54.0 | 79 | 4.5 |
| 6.8 | 6.8 | 202.5 | 57.0 | 84 | 4.7 |
| 7.8 | 7.8 | 210.5 | 59.0 | 88 | 4.9 |
| 9.1 | 9.1 | 218.5 | 61.0 | 92 | 5.1 |
| 10.9 | 10.9 | 232.5 | 65.0 | 99 | 5.3 |
| 11.9 | 11.9 | 238.5 | 66.0 | 102 | 5.9 |
| 13.3 | 13.3 | 246.5 | 68.0 | 106 | 6.1 |
| 14.3 | 14.3 | 254.5 | 70.0 | 110 | 6.3 |
*Note: the dimensions of other displacement combinations will not be listed one by one. Please contact us for more information.
Details

Tips: Reasons for insufficient oil or no oil pressure of the hydraulic tandem gear pump.
- Oil level of the hydraulic oil tank in hydraulic tandem gear pump is too low.
- The use of hydraulic oil does not meet the seasonal requirements.
- The oil inlet pipe of hydraulic tandem gear pump is seriously blocked by dirt.
- Oil seal of the main gear of hydraulic tandem gear pump is damaged, and air enters the hydraulic system.
- O-ring of the oil inlet and outlet joints or elbow joints is damaged. The fastening bolts of the elbow joints or the oil inlet and outlet pipe nuts are not fastened, causing air to enter the hydraulic system.
- The hydraulic tandem gear pump has internal leakage and the sealing ring is aging.
- End face of the hydraulic tandem gear pump or end face of the main and auxiliary gear sleeves is worn, and the unevenness of the end faces of the two shaft sleeves is out of tolerance.
- The hydraulic tandem gear pump internal parts assembly error, causing internal leakage.
- Left-handed and right-handed installation reversed, breaking the skeleton oil seal.
Product reviews
Running smoothly
Maks
7/22/2021 1:46 AM
I use this 3600 psi hydraulic tandem gear pump on a daily basis due to my job. It runs smoothly as described on the product page and can work in harsh environments. I am very happy to buy it at ATO.com.
Was this review helpful? (0/0)
Would this hydraulic tandem gear pump survive in a project that runs at 3400-3600rpm most of the time?
Tamire
3/27/2023 7:25 PM
Would this hydraulic tandem gear pump survive in a project that runs at 3400-3600rpm most of the time?
Was this review helpful? (0/0)
Can you three gear pumps in series of this size?
Betty
6/6/2023 3:50 AM
Can you three pumps in series of this size?
Rotation is CW.
Rotation is CW.
Was this review helpful? (0/0)
What should I do next?
Hahn
8/2/2023 12:50 AM
I received the hydraulic pump that I ordered and had it installed I am having a problem with it, it is only producing 2,000 psi and that was checked at the pump with a pressure gauge installed directly to pump. Please advice on what I should do next.
Was this review helpful? (0/0)
One question about hydraulic tandem gear pump
Hacoy
8/3/2023 1:24 AM
So the pressure regulators on the valves will have to be adjusted for the pump to produce? Just making sure I understand this so I do not damage the pump.
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
Electromagnetic Clutch, DC 24V, 6Nm/400Nm
ATO-EC-MCS1
$283.07
Shaft mounted electromagnetic clutch rated voltage DC 24V, static torque 400Nm, 200Nm, 100Nm, 50Nm, 25Nm, 15Nm, 6Nm is available, smooth operation, low vibration, fast response and overload protection.