0.2 HP (0.15 kW) Magnetic Drive Pump

$811.91
0.2 hp magnetic water pump adopts solid TEFC construction motor, painted with 2 parts epoxy paint. Magnetic drive pump operates at frequency of 50 and 60 Hz. Ceramic bearing and ceramic spindle achieve self priming magnetic drive pump long life expectancy. Mag drive pump widely used in chemical industry, pharmaceutical industry and metal industry.
SKU: ATO-MDP-02HP
Free Shipping
Delivery date: 10-12 days

Mag drive water pump offering ceramic bearing and ceramic spindle as standard wearing parts to achieve long life expectancy. 0.2 hp magnetic drive pump often used in applications where leak prevention is critical, such as handling corrosive chemicals, acids, or volatile substances.

Features:

  • The motor is of solid TEFC construction and is painted with 2 parts epoxy paint.
  • Offering ceramic bearing and ceramic spindle as standard wearing parts to achieve long life expectancy.
  • Standard connections available in hose, threads or union type.

Specification:

Rated Voltage3-phase 380V (contact us for other voltages)

ModelATO-200PS-F
Frequency50Hz, 60Hz
Connection MethodHose (mm)Thread (")Flange (A)
26×261×125×25
Pump Performance at Specific Point50Hz50 L/min
60Hz50 L/min
Rated Head50Hz5.5m
60Hz5.5m
Motor Output150W
Net Weight9kg


Dimension (Unit: mm)

PS-F magnetic drive pump dimension

ModelWHLabcdefg
200PS-F15616535570100205110667043.5


Application:

Magnetic drive pump application

Tips: Magnetic Drive Pump Troubleshooting

  • Loss of prime. Potential causes include a leaking suction line, air or gas in the fluid, a leaking foot valve, foreign matter in the impeller, or a leaking valve. Additionally, the foot valve or suction opening may not be sufficiently submerged, or the suction lift may be too high.
  • Excessive power consumption. Check for excessive flow, verify that the head is not lower than the rating, and confirm that the specific gravity and viscosity are not too high.
  • Vibration or noise. Check for foreign objects in the impeller. Ensure the motor and piping are properly secured. Look for drive magnet rubbing.

Proposition 65 Warning

*WARNING: This product can expose you to chemicals, including lead, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Product reviews
Great magnetic drive pump
5
benson
Avatar
3/20/2023 1:13 AM
I purchased this magnetic water pump to supply water to our refrigerator ice maker for ice. Magnetic pump runs quiet and provides adequate flow to the fridge. I am satisfied that it lifts the water and provides more pressure in my home setup.
Was this review helpful? Yes No (0/0)
Very reliable
4
Amy
Avatar
3/25/2026 8:36 PM
This pump handles acid transfer on our small chemical line with zero leaks. The ceramic bearings and shaft resist corrosion perfectly. The motor runs quietly, and the compact size saves space. Flanged connections make install and removal simple.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Mag drive water pump offering ceramic bearing and ceramic spindle as standard wearing parts to achieve long life expectancy. 0.2 hp magnetic drive pump often used in applications where leak prevention is critical, such as handling corrosive chemicals, acids, or volatile substances.

Features:

  • The motor is of solid TEFC construction and is painted with 2 parts epoxy paint.
  • Offering ceramic bearing and ceramic spindle as standard wearing parts to achieve long life expectancy.
  • Standard connections available in hose, threads or union type.

Specification:

Rated Voltage3-phase 380V (contact us for other voltages)

ModelATO-200PS-F
Frequency50Hz, 60Hz
Connection MethodHose (mm)Thread (")Flange (A)
26×261×125×25
Pump Performance at Specific Point50Hz50 L/min
60Hz50 L/min
Rated Head50Hz5.5m
60Hz5.5m
Motor Output150W
Net Weight9kg


Dimension (Unit: mm)

PS-F magnetic drive pump dimension

ModelWHLabcdefg
200PS-F15616535570100205110667043.5


Application:

Magnetic drive pump application

Tips: Magnetic Drive Pump Troubleshooting

  • Loss of prime. Potential causes include a leaking suction line, air or gas in the fluid, a leaking foot valve, foreign matter in the impeller, or a leaking valve. Additionally, the foot valve or suction opening may not be sufficiently submerged, or the suction lift may be too high.
  • Excessive power consumption. Check for excessive flow, verify that the head is not lower than the rating, and confirm that the specific gravity and viscosity are not too high.
  • Vibration or noise. Check for foreign objects in the impeller. Ensure the motor and piping are properly secured. Look for drive magnet rubbing.
Product reviews
Great magnetic drive pump
5
benson
Avatar
3/20/2023 1:13 AM
I purchased this magnetic water pump to supply water to our refrigerator ice maker for ice. Magnetic pump runs quiet and provides adequate flow to the fridge. I am satisfied that it lifts the water and provides more pressure in my home setup.
Was this review helpful? Yes No (0/0)
Very reliable
4
Amy
Avatar
3/25/2026 8:36 PM
This pump handles acid transfer on our small chemical line with zero leaks. The ceramic bearings and shaft resist corrosion perfectly. The motor runs quietly, and the compact size saves space. Flanged connections make install and removal simple.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews