Digital gas flow meters are available for flow range 0~20L/min with 6mm diameter and 0~250L/min with 12mm diameter. The gas mass flow meter is used for instant flow rate testing and flow accumulation calculation and suitable for different gas like compressed air, oxygen, nitrogen, CO2, Ar and other inactive gases, etc.
Specification
| Model | ATO-MF5706 | ATO-MF5708 | ATO-MF5712 | |
| Flow Range | 0~20L/min | 0~100 L/min | 0~250 L/min | |
| Power Supply | 4 AA batteries (LR6) or 5-24V DC | |||
| Power Adapter | Input: 100-240V AC, 50/60Hz, Output: 7V DC, 0.2A | |||
| Power Consumption | ≤10mW | |||
| Signal Output | RS 485 | |||
| Display | LCD | |||
| Display Unit | Instantaneous flow rate: L/min, Flow accumulation: m3 | |||
| Accuracy | ± (2.0+0.5FS)% | |||
| Instantaneous Flow Resolution | 0.01 L/min | |||
| Flow Accumulation Resolution | 0.001 m3 | |||
| Working Pressure | ≤0.8MPa | |||
| Pressure Loss | ≤600Pa | ≤1000Pa | ≤2000Pa | |
| Working Temperature | -10°C ~ +55°C | |||
| Humidity | 0~95%RH (non-condensing) | |||
| Keyboard | 3 keys | |||
| User Interface | Type-C USB port (This interface is connected to the power adapter for power supply, power cable is 0.5m, and it can also be used as a connection interface for 485 communication.) | |||
| Calibration | Air @20°C, 101.325kPa | |||
| DN | 6mm | 8mm | 12mm | |
| Mechanical Connection | NPT 1/4" | NPT 3/8" | NPT 1/2" | |
| Weight | 185g (Copper body) | 270g (Aluminium alloy body) | 350g (Aluminium alloy body) | |
| Protection Class | IP40 | |||
| Gas * | Air, N2, O2, Ar, CO2. For other gases, please contact us. | |||
| Accessories | 1. Power adapter, Type-C USB with 0.5m cable 2. RS485 data cable, Type-C USB port | |||
| Digital Gas Flow Meter User Manual | ||||
Dimension (Unit: mm)

| Model | L | W | D |
| ATO-MF5706 | 67 | 40 | NPT 1/4 |
| ATO-MF5712 | 98 | 50 | NPT 1/2 |
Detail

- LCD display or 180° rotating head can display instantaneous flow rate, totalized flow rate can be shared on the same screen.
- Gas flow meter adopts MEMS chip, high precision, low power consumption, no temperature and pressure compensation.
- Battery / power supply dual power supply, can use 4 AA batteries or external adapted power supply.
Accessories (optional)

Note: The optional miniUSB cable is used for the connection to external power supply and RS485 communication.
Application

Tips: Digital gas flow detector installation
The gas flow meter is preferably installed horizontally. Flow direction should be the same as the direction of the arrow mark on the meter body. If there may be particles or debris in the fluid, a filter is strongly recommended to be installed upstream of the meter.
Please follow the below steps to complete the installation:
- Check if the meter is complete, no visual damage first.
- Before installation, make sure that there is no debris or particles in the pipe.
- During installation, it is recommended to first install the inlet of the flow meter and then the outlet. To ensure the accuracy of measurement, the straight pipe length should be remained enough at the installation site of flow meter, upstream no less than 10 times DN and downstream no less than 5 times DN.
- Make sure all the wire connections of the flow meter is correct including the wires for LCD, input/output and communication.
- Turn on the power supply, and ensure that the LCD works properly.
- Slowly turn on the valve of the pipeline, and then the flow meter starts to measure the gas flow in the pipeline.
It is our pleasure to contact you.
My name is Anujin, a chemist, representative at Medimpex International LLC of Mongolia established in 2003 and a proud partner of Asian Development Bank, WHO, Luxemburg government, and other international and national institutions implementation of numerous projects of paramount importance in the health and education sector.
We supply medical diagnostic, health care and laboratory equipment, hospital disposables, machinery products, and tools to the Mongolian market for your information. Our company is an official distributor for Olympus- Endoscopy /Japan and Germany/, Siemens Healthcare, Draeger Medical /Germany/, Agilent technologies /US/, Standard Diagnostics /US/, etc.
As we are one of the leading suppliers, we care engineering and maintenance service after sales in our territory, we are a successful and best-known company in a sector of medical, laboratory and education equipment businesses.
Since we are expanding our sales in a related market, I would like to ask your cooperation and price offer on your products such as “Digital Gas Flow Meter, Air/Oxygen/Nitrogen, ATO-MF5706”.
For further discussion, please feel free to contact me back.
I will be waiting for the response at your earliest convenience.
Best Regards,
Anujin B.
https://www.ato.com/digital-gas-flow-meter?affiliate=shopping
When I click on the user manual on the webpage, on page 30 of the user manual I see the equation highlighted below.
If I purchase the 0-20 L/min flowmeter, how do I use this equation to figure out the accuracy?
If I plug in the full-scale flow rate of 20L/min, I get plus or minus 2.0 0.5*20 = 12%.
Is that correct?
What are the consequences of transgressing this guideline?
Is that likely to damage the sensor or will just cause the response time to be lower than your spec?
I am looking for a sensor that will measure airflow in a line used by a robotic gripper. The gripper should be using around 90 LPM, I will not have a practical way to supply de air "slowly" as the gripper uses electro valves that are opening in a matter of milliseconds.
I am testing compressed air flow rates through some of our assemblies and initially recorded the flow rates using Dwyer Rotameters. The idea to use a Digital Flow Meter instead of the Rotameters came up so we purchased your Meter with the Calibration Certificate.
I wanted to verify that similar measurements were recorded between the rotameter and Digital Flow Meter, so I put them in line with one another and ran compressed air through them.
Why am I seeing such different numbers?
I am trying to better understand the difference between a measurement of flow rate under working pressure and a measurement of flow rate under standard conditions.
I was under the impression that each device measures flow rate and there shouldn’t be a difference.
Compressed air (1.5” iron)
Novex (0.5” copper)
Argon (1” copper)
SF6 (0.5"" copper)
Thanks