Tension/Compression Load Cell, Low Profile, 500kg/30 ton to 100 ton

$145.28
Low profile load cell also known as pancake load cell, has flat design, high strength and good symmetry. Tension and compression load cell can be applied for platform scale, truck scale, rail weighbridge and material level measurement and control in warehouse, with good anti-eccentric load performance, low height, all sealed structure and complete specifications.
SKU: ATO-LC-P02
*
*
*
*
*
Free Shipping
Delivery date: 6-12 days

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Tension and compression load cells have capacity range from 500kg, 5 ton, 30 ton, 50 ton to 100 ton.

Specification

ModelATO-LCST-TJH-4B
Shipping Weight1.5~60kg
Capacity Range *500 kg~200 ton
Matched Display ControllerATO-TY5DA3 (Click it to the controller page)
Matched TransmitterATO-LCTR-NTB3K (Click it to the transmitter page)
Accuracy0.05%F.S (linearity + hysteresis + repeatability)
Sensitivity2.0±0.1mV/V
Creep±0.05%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.05%F.S/10℃
Temperature Effect on Output±0.05%F.S/10℃
Operating Temperature-20℃~+65℃
Input Impedance380±10Ω or 750±15Ω
Output Impedance350±3Ω or 700±5Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Bridge Voltage (excitation voltage)DC 5~10V
Response Time3-4ms
MaterialAlloy steel (Default) or stainless steel
Protection ClassIP67
Cable Length3m (<5 ton), 6m (≥5 ton)
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White


Feature

Compression load cell low profile 200kg to 100 ton feature

  • High-Quality Alloy Steel: Ensures durability, high strength, and resistance to wear and tear for long-lasting performance.
  • High Measurement Accuracy: Offers precise and stable measurements for reliable force detection.
  • Waterproof Connector: Uses a waterproof connector to reduce mechanical shock and ensure secure, stable signal transmission.
  • Easy Installation: Designed for easy installation with convenient mounting holes and straightforward setup.
  • Wide Range of Applications: Suitable for various industrial uses, including force measurement in manufacturing, weighing, and testing systems.

Dimension

CapacityDimension (mm)
ΦAΦBΦCΦFMHE
500kg~7 ton10588.96.532M16*1.53734
10~25 ton125101.68.539M32*1.55248
30~50 ton145116.810.550M40*1.55854
60~100 ton20516212.580M60*28578
200 ton29624522136M90*3105100

Compression load cell low profile 200kg to 100 ton dimension

Accessories dimension (accessories can be purchased in drop-down lists)

CapacityCompression head dimension (mm)
ΦL1LMSR
500kg~7 ton311328M16*1.580
10~25 ton382451M32*1.5120
30~50 ton503262M40*1.5200
60~100 ton804280M60*2280

Compression load cell low profile 200kg to 100 ton accessories dimension
Load cell module dimension (*module needs to be purchased separately)

CapacityDimension (mm)
LL1AA1HH1Φ
500kg~7 ton160135115901002011
10~25 ton2001601601251452513
30~50 ton2402001801351753017
60~100 ton3002602402002403517

Compression load cell module dimension

Wiring Method

Load cell wiring method

Application

Compression load cell low profile 200kg to 100 ton application

Tips: What kind of maintenance does the Tension/Compression Load Cell require?

Regular maintenance includes checking the load cell for signs of mechanical wear, corrosion, or damage. It’s important to inspect the connectors, wiring, and mounting system to ensure everything is secure. Periodic recalibration should also be done to ensure accurate measurements, especially after heavy use or exposure to extreme conditions.

How to Choose the Right Load Cell

Load cells are sensors used to measure the weight of an object. Their working principle is based on physical phenomena such as elastic deformation, electromagnetic force and pressure change, with high accuracy and reliability. These sensors can accurately measure the weight of an object for monitoring, control and recording. This video will help you choose the right load cell through six factors: Application, operating environment, material type and sealing technology, capacity/resolution requirements and output signal type.

In this video, we've shown you how to calibrate the weight transmitter Model 610 by ATO using a compression load cell so that you can make sure you get the most accurate readings possible in your measurement.

Product reviews
10 ton load cell for universal testing machine
5
Cameron
Avatar
12/20/2018 6:51 PM
I customized one 10 ton load cell which is used for the universal testing machine. After the customer service staff patiently explained, I understood the resistance also needed to be customized. Now I receive my load cell and can use it directly after finishing connection! The load cell accuracy is very good, load cell is very good, and the after-sales is also very good!
Was this review helpful? Yes No (0/0)
Question about load cell
5
Cory Salvesen
Avatar
4/1/2019 8:08 PM
I'm wondering if your load cell is affected by magnetic fields?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the output voltage signal of the Load Cell will be affected by the magnetic field, it is propotional to strength of the magnetic field.
Question about deflection
5
Matthew
Avatar
4/29/2021 11:05 AM
What would the deflection of this load cell be at highest load rating for the 5 ton variant?
Was this review helpful? Yes No (0/0)
ATO Responded
The deflection under the highest rated load of the load cell is about 0.3 mm.
Shock loads causing drift
5
Matthew
Avatar
5/20/2021 11:43 AM
Is there any knowledge of how much sudden shock loads cause drift in the load cell measurements?
Was this review helpful? Yes No (0/0)
ATO Responded
Temperature and overload will affect, every 10 degrees of temperature change, a change of ±0.05%, more than 150% of the range, will also change.
Tension/compression load cell usage
5
Margaretha
Avatar
5/31/2021 9:21 PM
Hello, I would like know if your tension/compression load cell ATO-LC-P02 works at 5Vdc excitation. I would like use this load cell with omron NX-RS1201 load cell input.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our load cell excitation voltage is 5-15VDC, and its output is about +/-25mV. So in order to get analog output signal, you will be needing to use transmitter.
Displacement of 500kg/30 tons to 100 tons load cell
5
Docdra
Avatar
8/27/2021 12:00 AM
SKU: ATO-LC-P02
Capacity: 5 tons.
Yes, I understand that, but I’m asking what the displacement (amount of movement from its original position) that the load cell experiences under maximum load.
Was this review helpful? Yes No (0/0)
ATO Responded
The displacement that the load cell experiences under maximum load will be approx 0.3mm for 5 ton capacity.
Working environment of load cell
5
Jmbs
Avatar
12/15/2021 1:56 AM
Hello, I would like to know if your tension/compression load cell ATO-LC-P02 works at 5Vdc excitation. I would like to use this load cell with iron NX-RS1201 load cell input.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our load cell excitation voltage is 5-15VDC, and its output is about +/-25mV. So in order to get an analog output signal, you will need to use a transmitter.
Questions about your load cell
5
Jone
Avatar
12/21/2021 11:10 PM
For your ATO-LC-P02 load cell, 100 ton capacity:
How much is the minimum measurable load?
What is the measurement increment?
Was this review helpful? Yes No (0/0)
ATO Responded
The minimum measurement is 0.01t, and the minimum increment is also 0.01t.
Load cell not having a zero mV at zero load
3
Diogo
Avatar
1/13/2022 4:07 AM
i have received the ATO-LC-P02 (5000kg range) and the load cell mV output with zero load is never zero instead it starts at ~35mV range. I have measure the resistances as follow: e /e-=396ohm; e /s-=298ohm; e /s =295ohm; e-/s- 295ohm; e-/s = 298; s-/s =352ohm. The load cell seem to have a linear behavour. we have send it to the calibration lab and it seems the sensitivity isnt matching 2mV/V. The calibration lab has not reported the zero issue, but they have reported the following values; 12.4VDC voltage, 1000kg-2.145mV, 2000Kg-4.263mV; 3000Kg-6.289mV; 4000Kg-8.315mV; 5000kg-10.412kg. If you could please advise on what the issue could be.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Determine the zero output and power supply.
2. From this data, the sensor is linear. If the power supply is 5.4v, the output is just right.
Load cell not having a zero mV at zero load
1
Diogo
Avatar
1/26/2022 3:00 AM
this is the latest table from the verification done at the lab.

Applied Reference Master  As Found (UUT)  Supply Voltage (UUT)
KN    mV DC  V DC
0.0    16.293   12.00
1.0    16.706  12.00
2.0    17.250  12.00
3.0  17.748  12.00
4.0  18.202  12.00
5.0  18.666  12.00
6.0    19.170  12.00
7.0    19.652  12.00
8.0    20.115  12.00
9.0    20.639  12.00
10.0  21.171  12.00
20.0  26.027  12.00
30.0  30.894  12.00
40.0  35.785  12.00
50.0  40.648  12.00
Was this review helpful? Yes No (0/0)
ATO Responded
What problems do you encounter in your experiment, please send your problems to this email support@ato.com.
Could you tell me the information about the true zero output and the total measurement error?
5
reilley
Avatar
3/3/2023 12:29 AM
We received the first 4 load cells from our order this week. Unfortunately, we are missing the calibration sheet. Could you tell me the information about the true zero output and the total measurement error?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do Not provide calibration sheets.
1. You can measure the output of load cells using a multimeter with an mv file.
2. If the sensor is powered by 5-15V DC, we recommend 10V dc power supply.
Note: Please do not use it beyond the range, the definition of wiring is on the certificate. If you encounter any problems during the test, you can contact us at any time.
Can you help us get past this load cell error?
5
benson
Avatar
7/10/2023 9:51 PM
We've already tried to follow that video step by step but are running into the following issue at 3:50-4:20 in the video.
When we try calibrating the weight, we get a message that says error 1.
We're calibrating using a 0.5 kg weight.
Can you help us get past this error?
Was this review helpful? Yes No (0/0)
ATO Responded
Your load cell capacity is 20 tons, so your calibration weight of 0.5kg is incorrect.
As we mentioned before, you're going to use 5%- 10% of the 20-ton capacity for the calibration.
Also, please pay attention to setting the display unit.
How to solve the problem of load cell?
5
gene
Avatar
7/17/2023 11:48 PM
I'd really appreciate more help here.
I've followed all the steps shown in the video, applied a weight of 1188 kg (between 5-10% of the 20-ton capacity), and am now getting error 2, see the attached video.
What should I do? If you can have someone call me and do this live with me that would be best.
Was this review helpful? Yes No (0/0)
ATO Responded
We think that error 2 is due to the light weight of the calibration.
Since your load cell is 20 tons, we recommend that you use the coefficient calibration method instead.
In this case, you only need a calibration weight of 500 kg.
For the specific operation method, please refer to the operation video: https://we.tl/t-qHexRzmtGh
Question of 500kg load cell hole
5
gaylen
Avatar
7/18/2023 3:02 AM
I'm looking at the 500kg capacity model: ATO-LCST-TJH-4B load cell. My goal is to figure out if the hole in the middle goes all the way through or only goes through most of the way.
I'm getting my info about it from this link:
https://www.ato.com/compression-load-cell-low-profile-200kg-to-100-ton?affiliate=shopping
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the 500kg capacity model: ATO-LCST-TJH-4B load cell has a threaded screw hole M16*1.5 in the middle.
This hole is through.
The minimum reading range of the load cell
5
kalan
Avatar
7/19/2023 3:13 AM
Hi, good morning
I have a question on this product SKU: ATO-LC-P02
What is the minimum reading range of the 1000 kg load cell?
And are there any other configurations available such as support where the device is placed?
Please send all specs of this item.
Was this review helpful? Yes No (0/0)
ATO Responded
1. The minimum reading range of the 1000 kg load cell is related to the display instrument, which is about 0.1 kg.
You can refer to our display controller: https://www.ato.com/5-digit-display-controller-for-pressure-sensor
2. Our load cell does not provide a mounting bracket, what equipment is your load cell installed on?
What is yellow wire meaning of load cell?
5
patryk
Avatar
7/19/2023 3:53 AM
SKU: ATO-LC-TC01
Hello, I bought this model and it has got 5 wires.
red   black - green white and yellow ones.
From the datasheet, I see that the yellow one is not mentioned
the yellow one is thicker.
Was this review helpful? Yes No (0/0)
ATO Responded
The yellow wire is a shielded wire, which can be grounded or left unconnected.
Can you tell me what the load cell thread size is for the center large hole?
5
yohya
Avatar
7/24/2023 3:31 AM
Can you tell me what the thread size is for the center large hole?
That hole has internal threads.
Was this review helpful? Yes No (0/0)
ATO Responded
The load cell with a 3-ton capacity. The thread of the center hole is M16*1.5mm.
What is the input voltage of the load cell?
5
xenia
Avatar
7/25/2023 2:39 AM
We purchased two of the load cells listed below.
What is the purpose of the yellow wire?
What is the input voltage?
Was this review helpful? Yes No (0/0)
ATO Responded
The yellow wire you mentioned is a shielded wire, so you don't need to connect it.
The input voltage of load cells is recommended to be 10V DC.
Can the load cell operate with 12V instead of 10V?
5
irving
Avatar
7/25/2023 7:37 PM
Can the system operate with 12 volts instead of 10 volts?
Was this review helpful? Yes No (0/0)
ATO Responded
The voltage range of our load cell supply is 5-12V DC, so 12V can also be used.
I am interested in larger tonnage load cell
5
amos
Avatar
8/20/2023 9:11 PM
I am interested in your larger tonnage units as I am testing the load capabilities of a new toggle press design. The problem is the 100-ton unit is slightly too tall while the 50-ton unit is too small for the readings. The machine reaches about 90 tons theoretically so is there a way to make the unit smaller in height?
Was this review helpful? Yes No (0/0)
ATO Responded
What is the maximum height that you need the sensor to fit in?
You can refer to this load cell, which has a smaller height.
Load Cell
5
Rory
Avatar
2/5/2024 12:44 AM
Does the module provide a flat surface to enable loading?
Was this review helpful? Yes No (0/0)
ATO Responded
The weighing module provides a concave surface to enable loading, not a flat surface.
I'm looking to use two of the 500kg pancake load cells
5
Caleena
Avatar
11/12/2024 11:43 PM
Hello, I'm looking to use two of the 500kg pancake load cells. I'm wondering how conservative the stated 0.05% FS/30 min creep error value is, and I'd also like to know what the approximate deflection of the load cell is at full capacity. Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
1. This creep error value is Not measurable by all load cells, and is generally Not as large as 0.05% FS/30 min.
2. When the full scale is reached, the accuracy of the 500kg range will be better, and the repeatability of full load can generally reach 0.03.
Good Quality of Tension/Compression Load Cell
5
Amily
Avatar
1/6/2025 12:50 AM
We recently purchased this Tension/Compression Load Cell, and it must be said that it is an excellent sensor! It has high precision, sturdy structure, strong durability, multifunctional design, wide applicability, easy installation and use, and impeccable performance, quality, and price. I will not hesitate to recommend it to friends who need precise measurement of tension/compression force!
Was this review helpful? Yes No (0/0)
Question about outer holes
5
Tobias
Avatar
3/5/2025 8:30 AM
On the drawing it looks like there are counterbore holes on the outer diameter, is that correct?

What is the depth of the counterbore?
Was this review helpful? Yes No (0/0)
ATO Responded
You can check the size of the hexagon socket bolt on the Internet according to the size of your hexagon socket screwdriver shown on the range comparison chart. They are similar.
20-Ton Load Cell
5
Luken
Avatar
9/30/2026 12:37 AM
My application scenario involves a maximum working load of 17,000 kg. I plan to use a thin, tension/compression load cell to monitor the load. My system needs a safety factor of 3, meaning the sensor must be able to withstand a load of 51,000 lbs (approximately 23,133 kg) without breaking. Can I use a 20-ton load cell?
Was this review helpful? Yes No (0/0)
ATO Responded
Our 20-ton load cell (ATO-LC-P02) can withstand a load of 51,000 lbs (approximately 23,133 kg) without breaking.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

After purchasing one ATO load cell, you can buy a special digital panel meter to obtain readings directly, or buy a transmitter to output standard signal to PLC, DCS and other systems. Customized output signal is 0-5V, 0-10V, or 4-20mA.

Note: The load cell cannot be connected to both the transmitter and the controller at the same time — only one can be selected.

Tension and compression load cells have capacity range from 500kg, 5 ton, 30 ton, 50 ton to 100 ton.

Specification

ModelATO-LCST-TJH-4B
Shipping Weight1.5~60kg
Capacity Range *500 kg~200 ton
Matched Display ControllerATO-TY5DA3 (Click it to the controller page)
Matched TransmitterATO-LCTR-NTB3K (Click it to the transmitter page)
Accuracy0.05%F.S (linearity + hysteresis + repeatability)
Sensitivity2.0±0.1mV/V
Creep±0.05%F.S/30min
Zero Output±1%F.S
Temperature Effect on Zero±0.05%F.S/10℃
Temperature Effect on Output±0.05%F.S/10℃
Operating Temperature-20℃~+65℃
Input Impedance380±10Ω or 750±15Ω
Output Impedance350±3Ω or 700±5Ω
Insulation Resistance≥5000MΩ
Safety Overload150%F.S
Bridge Voltage (excitation voltage)DC 5~10V
Response Time3-4ms
MaterialAlloy steel (Default) or stainless steel
Protection ClassIP67
Cable Length3m (<5 ton), 6m (≥5 ton)
WiringEXC+: Red, EXC-: Black, SIG+: Green, SIG-: White


Feature

Compression load cell low profile 200kg to 100 ton feature

  • High-Quality Alloy Steel: Ensures durability, high strength, and resistance to wear and tear for long-lasting performance.
  • High Measurement Accuracy: Offers precise and stable measurements for reliable force detection.
  • Waterproof Connector: Uses a waterproof connector to reduce mechanical shock and ensure secure, stable signal transmission.
  • Easy Installation: Designed for easy installation with convenient mounting holes and straightforward setup.
  • Wide Range of Applications: Suitable for various industrial uses, including force measurement in manufacturing, weighing, and testing systems.

Dimension

CapacityDimension (mm)
ΦAΦBΦCΦFMHE
500kg~7 ton10588.96.532M16*1.53734
10~25 ton125101.68.539M32*1.55248
30~50 ton145116.810.550M40*1.55854
60~100 ton20516212.580M60*28578
200 ton29624522136M90*3105100

Compression load cell low profile 200kg to 100 ton dimension

Accessories dimension (accessories can be purchased in drop-down lists)

CapacityCompression head dimension (mm)
ΦL1LMSR
500kg~7 ton311328M16*1.580
10~25 ton382451M32*1.5120
30~50 ton503262M40*1.5200
60~100 ton804280M60*2280

Compression load cell low profile 200kg to 100 ton accessories dimension
Load cell module dimension (*module needs to be purchased separately)

CapacityDimension (mm)
LL1AA1HH1Φ
500kg~7 ton160135115901002011
10~25 ton2001601601251452513
30~50 ton2402001801351753017
60~100 ton3002602402002403517

Compression load cell module dimension

Wiring Method

Load cell wiring method

Application

Compression load cell low profile 200kg to 100 ton application

Tips: What kind of maintenance does the Tension/Compression Load Cell require?

Regular maintenance includes checking the load cell for signs of mechanical wear, corrosion, or damage. It’s important to inspect the connectors, wiring, and mounting system to ensure everything is secure. Periodic recalibration should also be done to ensure accurate measurements, especially after heavy use or exposure to extreme conditions.

Product reviews
10 ton load cell for universal testing machine
5
Cameron
Avatar
12/20/2018 6:51 PM
I customized one 10 ton load cell which is used for the universal testing machine. After the customer service staff patiently explained, I understood the resistance also needed to be customized. Now I receive my load cell and can use it directly after finishing connection! The load cell accuracy is very good, load cell is very good, and the after-sales is also very good!
Was this review helpful? Yes No (0/0)
Question about load cell
5
Cory Salvesen
Avatar
4/1/2019 8:08 PM
I'm wondering if your load cell is affected by magnetic fields?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the output voltage signal of the Load Cell will be affected by the magnetic field, it is propotional to strength of the magnetic field.
Question about deflection
5
Matthew
Avatar
4/29/2021 11:05 AM
What would the deflection of this load cell be at highest load rating for the 5 ton variant?
Was this review helpful? Yes No (0/0)
ATO Responded
The deflection under the highest rated load of the load cell is about 0.3 mm.
Shock loads causing drift
5
Matthew
Avatar
5/20/2021 11:43 AM
Is there any knowledge of how much sudden shock loads cause drift in the load cell measurements?
Was this review helpful? Yes No (0/0)
ATO Responded
Temperature and overload will affect, every 10 degrees of temperature change, a change of ±0.05%, more than 150% of the range, will also change.
Tension/compression load cell usage
5
Margaretha
Avatar
5/31/2021 9:21 PM
Hello, I would like know if your tension/compression load cell ATO-LC-P02 works at 5Vdc excitation. I would like use this load cell with omron NX-RS1201 load cell input.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our load cell excitation voltage is 5-15VDC, and its output is about +/-25mV. So in order to get analog output signal, you will be needing to use transmitter.
Displacement of 500kg/30 tons to 100 tons load cell
5
Docdra
Avatar
8/27/2021 12:00 AM
SKU: ATO-LC-P02
Capacity: 5 tons.
Yes, I understand that, but I’m asking what the displacement (amount of movement from its original position) that the load cell experiences under maximum load.
Was this review helpful? Yes No (0/0)
ATO Responded
The displacement that the load cell experiences under maximum load will be approx 0.3mm for 5 ton capacity.
Working environment of load cell
5
Jmbs
Avatar
12/15/2021 1:56 AM
Hello, I would like to know if your tension/compression load cell ATO-LC-P02 works at 5Vdc excitation. I would like to use this load cell with iron NX-RS1201 load cell input.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our load cell excitation voltage is 5-15VDC, and its output is about +/-25mV. So in order to get an analog output signal, you will need to use a transmitter.
Questions about your load cell
5
Jone
Avatar
12/21/2021 11:10 PM
For your ATO-LC-P02 load cell, 100 ton capacity:
How much is the minimum measurable load?
What is the measurement increment?
Was this review helpful? Yes No (0/0)
ATO Responded
The minimum measurement is 0.01t, and the minimum increment is also 0.01t.
Load cell not having a zero mV at zero load
3
Diogo
Avatar
1/13/2022 4:07 AM
i have received the ATO-LC-P02 (5000kg range) and the load cell mV output with zero load is never zero instead it starts at ~35mV range. I have measure the resistances as follow: e /e-=396ohm; e /s-=298ohm; e /s =295ohm; e-/s- 295ohm; e-/s = 298; s-/s =352ohm. The load cell seem to have a linear behavour. we have send it to the calibration lab and it seems the sensitivity isnt matching 2mV/V. The calibration lab has not reported the zero issue, but they have reported the following values; 12.4VDC voltage, 1000kg-2.145mV, 2000Kg-4.263mV; 3000Kg-6.289mV; 4000Kg-8.315mV; 5000kg-10.412kg. If you could please advise on what the issue could be.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Determine the zero output and power supply.
2. From this data, the sensor is linear. If the power supply is 5.4v, the output is just right.
Load cell not having a zero mV at zero load
1
Diogo
Avatar
1/26/2022 3:00 AM
this is the latest table from the verification done at the lab.

Applied Reference Master  As Found (UUT)  Supply Voltage (UUT)
KN    mV DC  V DC
0.0    16.293   12.00
1.0    16.706  12.00
2.0    17.250  12.00
3.0  17.748  12.00
4.0  18.202  12.00
5.0  18.666  12.00
6.0    19.170  12.00
7.0    19.652  12.00
8.0    20.115  12.00
9.0    20.639  12.00
10.0  21.171  12.00
20.0  26.027  12.00
30.0  30.894  12.00
40.0  35.785  12.00
50.0  40.648  12.00
Was this review helpful? Yes No (0/0)
ATO Responded
What problems do you encounter in your experiment, please send your problems to this email support@ato.com.
Could you tell me the information about the true zero output and the total measurement error?
5
reilley
Avatar
3/3/2023 12:29 AM
We received the first 4 load cells from our order this week. Unfortunately, we are missing the calibration sheet. Could you tell me the information about the true zero output and the total measurement error?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we do Not provide calibration sheets.
1. You can measure the output of load cells using a multimeter with an mv file.
2. If the sensor is powered by 5-15V DC, we recommend 10V dc power supply.
Note: Please do not use it beyond the range, the definition of wiring is on the certificate. If you encounter any problems during the test, you can contact us at any time.
Can you help us get past this load cell error?
5
benson
Avatar
7/10/2023 9:51 PM
We've already tried to follow that video step by step but are running into the following issue at 3:50-4:20 in the video.
When we try calibrating the weight, we get a message that says error 1.
We're calibrating using a 0.5 kg weight.
Can you help us get past this error?
Was this review helpful? Yes No (0/0)
ATO Responded
Your load cell capacity is 20 tons, so your calibration weight of 0.5kg is incorrect.
As we mentioned before, you're going to use 5%- 10% of the 20-ton capacity for the calibration.
Also, please pay attention to setting the display unit.
How to solve the problem of load cell?
5
gene
Avatar
7/17/2023 11:48 PM
I'd really appreciate more help here.
I've followed all the steps shown in the video, applied a weight of 1188 kg (between 5-10% of the 20-ton capacity), and am now getting error 2, see the attached video.
What should I do? If you can have someone call me and do this live with me that would be best.
Was this review helpful? Yes No (0/0)
ATO Responded
We think that error 2 is due to the light weight of the calibration.
Since your load cell is 20 tons, we recommend that you use the coefficient calibration method instead.
In this case, you only need a calibration weight of 500 kg.
For the specific operation method, please refer to the operation video: https://we.tl/t-qHexRzmtGh
Question of 500kg load cell hole
5
gaylen
Avatar
7/18/2023 3:02 AM
I'm looking at the 500kg capacity model: ATO-LCST-TJH-4B load cell. My goal is to figure out if the hole in the middle goes all the way through or only goes through most of the way.
I'm getting my info about it from this link:
https://www.ato.com/compression-load-cell-low-profile-200kg-to-100-ton?affiliate=shopping
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the 500kg capacity model: ATO-LCST-TJH-4B load cell has a threaded screw hole M16*1.5 in the middle.
This hole is through.
The minimum reading range of the load cell
5
kalan
Avatar
7/19/2023 3:13 AM
Hi, good morning
I have a question on this product SKU: ATO-LC-P02
What is the minimum reading range of the 1000 kg load cell?
And are there any other configurations available such as support where the device is placed?
Please send all specs of this item.
Was this review helpful? Yes No (0/0)
ATO Responded
1. The minimum reading range of the 1000 kg load cell is related to the display instrument, which is about 0.1 kg.
You can refer to our display controller: https://www.ato.com/5-digit-display-controller-for-pressure-sensor
2. Our load cell does not provide a mounting bracket, what equipment is your load cell installed on?
What is yellow wire meaning of load cell?
5
patryk
Avatar
7/19/2023 3:53 AM
SKU: ATO-LC-TC01
Hello, I bought this model and it has got 5 wires.
red   black - green white and yellow ones.
From the datasheet, I see that the yellow one is not mentioned
the yellow one is thicker.
Was this review helpful? Yes No (0/0)
ATO Responded
The yellow wire is a shielded wire, which can be grounded or left unconnected.
Can you tell me what the load cell thread size is for the center large hole?
5
yohya
Avatar
7/24/2023 3:31 AM
Can you tell me what the thread size is for the center large hole?
That hole has internal threads.
Was this review helpful? Yes No (0/0)
ATO Responded
The load cell with a 3-ton capacity. The thread of the center hole is M16*1.5mm.
What is the input voltage of the load cell?
5
xenia
Avatar
7/25/2023 2:39 AM
We purchased two of the load cells listed below.
What is the purpose of the yellow wire?
What is the input voltage?
Was this review helpful? Yes No (0/0)
ATO Responded
The yellow wire you mentioned is a shielded wire, so you don't need to connect it.
The input voltage of load cells is recommended to be 10V DC.
Can the load cell operate with 12V instead of 10V?
5
irving
Avatar
7/25/2023 7:37 PM
Can the system operate with 12 volts instead of 10 volts?
Was this review helpful? Yes No (0/0)
ATO Responded
The voltage range of our load cell supply is 5-12V DC, so 12V can also be used.
I am interested in larger tonnage load cell
5
amos
Avatar
8/20/2023 9:11 PM
I am interested in your larger tonnage units as I am testing the load capabilities of a new toggle press design. The problem is the 100-ton unit is slightly too tall while the 50-ton unit is too small for the readings. The machine reaches about 90 tons theoretically so is there a way to make the unit smaller in height?
Was this review helpful? Yes No (0/0)
ATO Responded
What is the maximum height that you need the sensor to fit in?
You can refer to this load cell, which has a smaller height.
Load Cell
5
Rory
Avatar
2/5/2024 12:44 AM
Does the module provide a flat surface to enable loading?
Was this review helpful? Yes No (0/0)
ATO Responded
The weighing module provides a concave surface to enable loading, not a flat surface.
I'm looking to use two of the 500kg pancake load cells
5
Caleena
Avatar
11/12/2024 11:43 PM
Hello, I'm looking to use two of the 500kg pancake load cells. I'm wondering how conservative the stated 0.05% FS/30 min creep error value is, and I'd also like to know what the approximate deflection of the load cell is at full capacity. Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
1. This creep error value is Not measurable by all load cells, and is generally Not as large as 0.05% FS/30 min.
2. When the full scale is reached, the accuracy of the 500kg range will be better, and the repeatability of full load can generally reach 0.03.
Good Quality of Tension/Compression Load Cell
5
Amily
Avatar
1/6/2025 12:50 AM
We recently purchased this Tension/Compression Load Cell, and it must be said that it is an excellent sensor! It has high precision, sturdy structure, strong durability, multifunctional design, wide applicability, easy installation and use, and impeccable performance, quality, and price. I will not hesitate to recommend it to friends who need precise measurement of tension/compression force!
Was this review helpful? Yes No (0/0)
Question about outer holes
5
Tobias
Avatar
3/5/2025 8:30 AM
On the drawing it looks like there are counterbore holes on the outer diameter, is that correct?

What is the depth of the counterbore?
Was this review helpful? Yes No (0/0)
ATO Responded
You can check the size of the hexagon socket bolt on the Internet according to the size of your hexagon socket screwdriver shown on the range comparison chart. They are similar.
20-Ton Load Cell
5
Luken
Avatar
9/30/2026 12:37 AM
My application scenario involves a maximum working load of 17,000 kg. I plan to use a thin, tension/compression load cell to monitor the load. My system needs a safety factor of 3, meaning the sensor must be able to withstand a load of 51,000 lbs (approximately 23,133 kg) without breaking. Can I use a 20-ton load cell?
Was this review helpful? Yes No (0/0)
ATO Responded
Our 20-ton load cell (ATO-LC-P02) can withstand a load of 51,000 lbs (approximately 23,133 kg) without breaking.
Only registered users can write reviews
Customers who bought this item also bought

Digital Load Cell Amplifier, Output 4-20mA/0-10V/RS485

ATO-LCTR-OAR
$109.85
High precision load cell amplifier has a 6 digit LED display, output signal 4-20mA/ 0-5V/ 0-10V/ RS485. There are 3 keys for parameter settings. Digital load cell amplifier can be calibrated on-line by its 3 keys. The setting parameters include zero, capacity, communication rate, division value, decimal digits, etc.

5 Digit Display Controller for Load Cells

ATO-DPM-LC5D
$210.80
Digital panel meter can cooperate with load cells, force sensors and weighing sensors, two outputs for data comparison, digital panel meter can display gross, net, peak and valley value alternately.

Load Cell Junction Box for Scales, 2/3/4/6/8/10 Inlets to 1 Outlet

ATO-LCBOX-10I
$66.67
Multi-channel load cell junction box has 2/3/4/6/8/10 inlets and 1 outlet, aluminum alloy casing, good anti-interference, special for waterproof sealing joint, waterproof and dustproof rubber gasket for cover, easy to assemble and debug. Each channel can be adjusted balance to prevent damage to the sensor caused by inductive lightning and surge signals.

Load Cell Transmitter, Output 0-5V/0-10V/4-20mA

ATO-LCTR-OA
$81.27
Load cell transmitter is made of aluminum alloy, output standard signal 0-5V/0-10V/4-20mA, has linear compensation, humidity compensation, external zero debugging, external span debugging, input overload protection and output short circuit protection functions.

Thermocouple, T type, Sheath

ATO-TC-TS
$49.23
T type thermocouple has the highest accuracy and lowest price in base metals. Sheath thermocouple have shielded thermocouple wire of common length 500mm and sheath diameter Ф3~Φ8mm, with flexibility, high pressure resistant, fast thermal response time and long operating life. T type thermocouple can directly measure the temperature of liquid, vapor, gas medium and solid surface in the range of -200~+350 ℃ in various production processes.