3 hp (2.2 kW) VFD, Single Phase Input & Output

$379.23
Cheap 3 hp VFD, 1 phase for single phase AC induction motor, good variable speed performance, 220V - 240V 17 amps, manufacturer direct sale.
SKU: GK3000-1S0022
Availability: In stock
Free Shipping
Delivery date: 2-3 days

3 hp variable frequency drive, 2.2 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0022
Capacity3 hp (2.2 kW)
Shipping weight3 kg
Dimension230*118*163 mm
I/O FeatureRated current17 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuates
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

2200W Single Phase VFD Details

Tips: Irrational application in variable frequency drive energy-saving
The variable frequency drive is a power-saving control product, but it can't be used to save energy in every occasion. In fact, the VFD is able to save energy through adjusting the motor speed, and it has slightly higher efficiency and power factor than other speed control equipment. If the variable frequency drive can achieve energy saving is determined by the speed characteristics of the load.
For centrifugal fans or centrifugal pumps loads, the torque is proportional to the square of the speed, and the power is proportional to the cube of the speed. As long as uses the valve to control the flow, and not in full load operating, using speed control operation can achieve energy saving. When the speed dropped to 80% of the original, the power is only 51.2%of the original. We can see that the VFD has obvious energy saving effect in this type of load applications. For Roots blower loads, the torque is independent of the magnitude of the speed, that is, it is constant torque load. The original uses exhaust valve to discharge excess air flow and to adjust the air volume, if uses speed control operation, it can also achieve energy saving. When the speed dropped to 80% of the original, the power will drop to 80%, the energy-saving effect is much lower. For constant power loads, power is independent of the speed. Such as the ingredients belt scale, under the set flow conditions, when the material layer is thick, the belt speed down. When the material layer is thin, the belt speeds up. In this type of load applications, the VFD cannot achieve energy saving.

Running a single phase motor with VFD

In this video, ATO will show you details about running a single phase motor on a VFD. It's important to note that there are two wiring methods for single phase motor connecting to ATO single phase VFD: wiring of removing motor capacitor & wiring of keeping motor capacitor. At first, you should choose the wiring method you needed, and then set basic parameters step by step.

Four Ways to Control VFD with PLC

This video introduces the main wiring methods between PLC and VFD, including digital control, analog control, serial communication and Ethernet connection. The choice of connection method depends on the specific application requirements, system complexity, cost considerations and the need for control accuracy and flexibility.

How to Choose a VFD for Your Motor?

In this video, we lay out a list of key factors that should guide you in choosing the right VFD for your motor or any other possible application.

VFD analog input 0-10V frequency control (VI port)

Single-phase Output VFD Controls Single-phase Motor Speed

This video shows the details of using a frequency converter to run a single-phase motor on a single-phase power supply. Including wiring, parameter setting, single-phase motor speed control, etc.

Product reviews
3 hp single phase 220v VFD
5
Johan
Avatar
10/26/2018 12:57 AM
I bought a 3 hp single phase input and output  VFD to change the speed of my single phase motor, the VFD works very well. I will purchase again if needed.
Was this review helpful? Yes No (0/0)
3 hp (2.2 kW) VFD, Single Phase Input
5
Gert
Avatar
11/18/2018 7:30 AM
This is the best service I got from any online purchase. From selecting the correct product, wiring and setup.
working excellently.
thanks
Was this review helpful? Yes No (0/0)
Super fast shipping!
5
Stivi
Avatar
2/22/2021 2:03 PM
I'll have to right a review on the vfd itself but wow on the shipping super fast!!
Was this review helpful? Yes No (0/0)
3hp (2.2kW) VFD can single-phase input and output
5
Gadget
Avatar
3/7/2021 7:44 PM
Can your GK3000-1S0022 3hp (2.2kW) VFD handle 1-phase and 3-phase motors?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this 3hp (2.2kW) VFD can handle 1-phase and 3-phase motors.
Information about single-phase input and output VFD
5
Kurth
Avatar
6/1/2021 1:30 AM
I would like to know if the 1 phase to 1 phase smallest VFD comes with modbus RTU protocol.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, and all our VFDs have modbus RTU protocol. Information about single-phase input and output VFD.
Use of 1 phase VFD
5
Gnotel
Avatar
6/23/2021 9:04 PM
Can I use your 1 phase drive with a permanent split capacitor motor?
Was this review helpful? Yes No (0/0)
ATO Responded
No, cannot be used for permanent split capacitor motor.
How to read information from 3hp variable frequency drive through Windows10PC?
5
Jonnat
Avatar
11/1/2021 8:56 PM
How do I communicate via a Windows 10 PC to read info (rpm, hz, input sensor info, amps, volts, etc.) from your 3 hp variable frequency drive "model GK3000-1S0022"?
Was this review helpful? Yes No (0/0)
ATO Responded
You can use HMI + PLC and communicate through RS485 to achieve required data monitoring.
I am having trouble making VFD work with a 3 hp single phase motor
5
Fred
Avatar
5/26/2022 9:25 PM
I purchased an ATO 3 hp 2.2 kW VFD, 220V Single Phase Input & Output Variable Frequency Drive, but I am having trouble making it work with a 3hp single phase motor. Can someone contact me to help ensure we are wiring and configuring this properly? Unfortunately we will have to return if we cannot make it work properly.
Was this review helpful? Yes No (0/0)
ATO Responded
Could you please describe in detail what caused it to fail? If possible please provide us a video of the VFD running. You could refer to this video about connecting the VFD to the motor. Plz see on  https://www.youtube.com/watch?v=D8zavX-9vVw&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=15
Can you help with this matter?
5
Tammie
Avatar
7/27/2022 1:53 AM
I keep receiving Error 10 during my startup. Can you help with this matter?
Here's some info that I have.
Inverter: EM15-SP 1S1-1D5, this connect to run a belt sander.
Motor specs: Model: F56C1.5S2C
HP: 1.5
RPM: 3520
Voltage: 230
Frequency: 60Hz
Amps: 6.23 FLA, LRA 49
P.S. I did measure the amperage during start up and it was only 18amp before it would shut down and give that Error 10.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD displays error code Error 10 indicating overload. We noticed this Inverter: EM15-SP 1S1-1D5 output rated current is 7A, while your motor FLA is 6.23A. The current of the motor is very close to the rated current of the VFD, which can easily lead to overloading.
Now please set the VFD parameter to FE-00=0, connecting the power cord of the single-phase motor to the VFD output terminals U, V, and test again.
If there is still a problem, we recommend you to replace the VFD with a larger capacity and please send us with your motor nameplate for confirmation.
Is there a way to program this vfd?
5
rudy
Avatar
6/6/2023 7:49 PM
After starting the motor can U drop out on the second Mary winding ?
Is there a way to program this?
Or shut off the start winding which is in the U terminal?
My amps are too high at 15 amps.
Was this review helpful? Yes No (0/0)
ATO Responded
1. First of all, the wiring between the VFD and the motor is fixed, so you cannot modify the wiring of the motor through programming or manually after starting the motor. As we mentioned before, the forward and reverse rotation of a single-phase motor requires manual modification of the terminal wiring.
2. The starting current of the motor is related to the load capacity. If the load capacity is relatively large, the starting current will also be large. In order to help you solve the problem, please provide your VFD and motor nameplate label to us for further confirmation.
Please also provide your single-phase motor manual. We need the wiring diagram of the motor for further confirmation. Thank you for your understanding.
We need help with single phase VFD
5
tzivia
Avatar
6/15/2023 8:22 PM
We need help with E01 code on a gk3000 1s0022g 2.2 kw connected to a 3hp 220v 1 phase in and out. The manual send does not match.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we can not find your order number, please provide us with the order number and your motor nameplate picture for further confirmation. We hope to provide you with better service. What is the load on your motor?
The E01 code is caused by VFD accelerated running over-current, you can try setting:
1. Please extend the acceleration and deceleration time. (set parameter P0.17)
2. Please adjust the V/F curve.(set parameter P0.22=2 or 3)
3. If the VFD power is too small, you need to replace it with a higher power one.
How do I get VFD to run in constant pressure mode?
5
blanche
Avatar
7/20/2023 8:26 PM
Had to change the pump which is run by the 2.2kw GK3000 single-phase VFD and now it is not going into constant pressure mode.  It runs to the set pressure and goes to hibernate frequency for a period of time and shuts off.  Starts back up at low revival pressure and repeats the cycle.
How do I get it to run in constant pressure mode again?
I cannot change this variable:  P7.05.  
How do I change it?  
It currently appears to change based on P7.08 and P7.09

P7.00     1
P7.05     340 or 200 toggles between the two numbers (will not change)
P7.19     225
P7.20     340
P7.26     1
P7.27     950
Was this review helpful? Yes No (0/0)
ATO Responded
If you don’t need the sleep pressure function, please set the sleep pressure position P7.20=P7.05 (set pressure 340 or 200), P7.22=0 (sleep frequency), and test again
VFD sleep frequency setting
5
logan
Avatar
7/20/2023 9:54 PM
I need a sleep frequency as the pump will not flow below the set value.
What triggers the vfd to go into continuous pressure mode vs going to sleep mode?
Was this review helpful? Yes No (0/0)
ATO Responded
If you want the continuous pressure mode, you can only remove the sleep pressure.
If you want the sleep pressure, then set the sleep pressure, the two are not compatible at the same time, you can only choose one.
Sleep pressure means that after the actual pressure reaches the set pressure, the VFD will enter sleep mode and stop running.
When the pressure drops to the sleep pressure, the VFD will automatically restart until the set pressure is reached again.
Question on connectiion
5
Kristen
Avatar
10/17/2023 12:44 AM
Where do I find The L1 &L2 connection ? there is no connection to suite top or middle.
Was this review helpful? Yes No (0/0)
ATO Responded
Are the L1 and L2 you are talking about the power connections for the VFD input? The VFD input terminal can be connected to the R and S terminals, please refer to the attached picture.
About installation
4
Zackn
Avatar
7/15/2024 2:58 AM
After purchasing your ATO single phase input/output VFD 3hp unit, I am finally going to install it. Turn off the phase loss protection: set PA=0; I assume this is still required?
I would like to keep the capacitors, so my input power 240VAC goes to L1 & L2 with the output going to the motor via U & V or V & W with E for ground. Is this correct? I would like to run the motor at approximately 300-500 rpm without damaging the motor. Is this OK?
Was this review helpful? Yes No (0/0)
ATO Responded
1. You still need to turn off the phase loss protection: set PA.13=0; Since your motor is a single-phase motor, we do not recommend running the motor below 40Hz for a long time, otherwise the single-phase motor will easily heat up.
2. Regarding VFD wiring: Yes, your input power 240VAC goes to L1 & L2 with the output going to the motor via U & V or V & W with E for ground. Please free to contact us if you have other questions.
The parameters for the drive restart
5
Lorenzo
Avatar
11/21/2024 1:30 AM
What are the parameters for the drive restart after power loss?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD does not have a power-off restart parameter. If you use the terminal control start, the power is cut off and then restored when the terminal is closed, and the VFD will run if the terminal is still closed.
I'm having trouble Installing my VFD
4
Lindor
Avatar
2/27/2025 12:39 AM
I'm trying to install it on a Leeson 3hp single phase motor 230V input with run/start capacitors. When I installed it the motor just rock back and forward not making 1 compete turn so I'm thinking that I Program it wrong but I cannot find ANYTHING to tell me how to do a factory reset.
So, we left that one alone and we try to install it on a different motor a Rockwell same size and output as the Leeson. This time it ran but we burn out the start capacitors I am an electrician but I have never installed a VFD before I feel that I have it wired right.
Was this review helpful? Yes No (0/0)
ATO Responded
First of all, the forward and reverse rotation of the single-phase motor can only be achieved by changing the motor wiring method. And the forward and reverse rotation can Not be changed directly through the VFD (only three-phase motors can).
In addition, the wiring of the single-phase motor can maintain the capacitor wiring method, but the motor can Not run at low speed and low frequency. We recommend running the single-phase motor above 40HZ, otherwise the running capacitor will heat up and be damaged. This is determined by the principle of the single-phase motor.
So, if you want to adjust the motor speed, you need to change to a three-phase motor. For the wiring and use of single-phase motors, refer to this video: https://www.youtube.com/watch?v=jiVpJAY84MQ&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=5
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3 hp variable frequency drive, 2.2 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0022
Capacity3 hp (2.2 kW)
Shipping weight3 kg
Dimension230*118*163 mm
I/O FeatureRated current17 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuates
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

2200W Single Phase VFD Details

Tips: Irrational application in variable frequency drive energy-saving
The variable frequency drive is a power-saving control product, but it can't be used to save energy in every occasion. In fact, the VFD is able to save energy through adjusting the motor speed, and it has slightly higher efficiency and power factor than other speed control equipment. If the variable frequency drive can achieve energy saving is determined by the speed characteristics of the load.
For centrifugal fans or centrifugal pumps loads, the torque is proportional to the square of the speed, and the power is proportional to the cube of the speed. As long as uses the valve to control the flow, and not in full load operating, using speed control operation can achieve energy saving. When the speed dropped to 80% of the original, the power is only 51.2%of the original. We can see that the VFD has obvious energy saving effect in this type of load applications. For Roots blower loads, the torque is independent of the magnitude of the speed, that is, it is constant torque load. The original uses exhaust valve to discharge excess air flow and to adjust the air volume, if uses speed control operation, it can also achieve energy saving. When the speed dropped to 80% of the original, the power will drop to 80%, the energy-saving effect is much lower. For constant power loads, power is independent of the speed. Such as the ingredients belt scale, under the set flow conditions, when the material layer is thick, the belt speed down. When the material layer is thin, the belt speeds up. In this type of load applications, the VFD cannot achieve energy saving.

Product reviews
3 hp single phase 220v VFD
5
Johan
Avatar
10/26/2018 12:57 AM
I bought a 3 hp single phase input and output  VFD to change the speed of my single phase motor, the VFD works very well. I will purchase again if needed.
Was this review helpful? Yes No (0/0)
3 hp (2.2 kW) VFD, Single Phase Input
5
Gert
Avatar
11/18/2018 7:30 AM
This is the best service I got from any online purchase. From selecting the correct product, wiring and setup.
working excellently.
thanks
Was this review helpful? Yes No (0/0)
Super fast shipping!
5
Stivi
Avatar
2/22/2021 2:03 PM
I'll have to right a review on the vfd itself but wow on the shipping super fast!!
Was this review helpful? Yes No (0/0)
3hp (2.2kW) VFD can single-phase input and output
5
Gadget
Avatar
3/7/2021 7:44 PM
Can your GK3000-1S0022 3hp (2.2kW) VFD handle 1-phase and 3-phase motors?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this 3hp (2.2kW) VFD can handle 1-phase and 3-phase motors.
Information about single-phase input and output VFD
5
Kurth
Avatar
6/1/2021 1:30 AM
I would like to know if the 1 phase to 1 phase smallest VFD comes with modbus RTU protocol.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, and all our VFDs have modbus RTU protocol. Information about single-phase input and output VFD.
Use of 1 phase VFD
5
Gnotel
Avatar
6/23/2021 9:04 PM
Can I use your 1 phase drive with a permanent split capacitor motor?
Was this review helpful? Yes No (0/0)
ATO Responded
No, cannot be used for permanent split capacitor motor.
How to read information from 3hp variable frequency drive through Windows10PC?
5
Jonnat
Avatar
11/1/2021 8:56 PM
How do I communicate via a Windows 10 PC to read info (rpm, hz, input sensor info, amps, volts, etc.) from your 3 hp variable frequency drive "model GK3000-1S0022"?
Was this review helpful? Yes No (0/0)
ATO Responded
You can use HMI + PLC and communicate through RS485 to achieve required data monitoring.
I am having trouble making VFD work with a 3 hp single phase motor
5
Fred
Avatar
5/26/2022 9:25 PM
I purchased an ATO 3 hp 2.2 kW VFD, 220V Single Phase Input & Output Variable Frequency Drive, but I am having trouble making it work with a 3hp single phase motor. Can someone contact me to help ensure we are wiring and configuring this properly? Unfortunately we will have to return if we cannot make it work properly.
Was this review helpful? Yes No (0/0)
ATO Responded
Could you please describe in detail what caused it to fail? If possible please provide us a video of the VFD running. You could refer to this video about connecting the VFD to the motor. Plz see on  https://www.youtube.com/watch?v=D8zavX-9vVw&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=15
Can you help with this matter?
5
Tammie
Avatar
7/27/2022 1:53 AM
I keep receiving Error 10 during my startup. Can you help with this matter?
Here's some info that I have.
Inverter: EM15-SP 1S1-1D5, this connect to run a belt sander.
Motor specs: Model: F56C1.5S2C
HP: 1.5
RPM: 3520
Voltage: 230
Frequency: 60Hz
Amps: 6.23 FLA, LRA 49
P.S. I did measure the amperage during start up and it was only 18amp before it would shut down and give that Error 10.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD displays error code Error 10 indicating overload. We noticed this Inverter: EM15-SP 1S1-1D5 output rated current is 7A, while your motor FLA is 6.23A. The current of the motor is very close to the rated current of the VFD, which can easily lead to overloading.
Now please set the VFD parameter to FE-00=0, connecting the power cord of the single-phase motor to the VFD output terminals U, V, and test again.
If there is still a problem, we recommend you to replace the VFD with a larger capacity and please send us with your motor nameplate for confirmation.
Is there a way to program this vfd?
5
rudy
Avatar
6/6/2023 7:49 PM
After starting the motor can U drop out on the second Mary winding ?
Is there a way to program this?
Or shut off the start winding which is in the U terminal?
My amps are too high at 15 amps.
Was this review helpful? Yes No (0/0)
ATO Responded
1. First of all, the wiring between the VFD and the motor is fixed, so you cannot modify the wiring of the motor through programming or manually after starting the motor. As we mentioned before, the forward and reverse rotation of a single-phase motor requires manual modification of the terminal wiring.
2. The starting current of the motor is related to the load capacity. If the load capacity is relatively large, the starting current will also be large. In order to help you solve the problem, please provide your VFD and motor nameplate label to us for further confirmation.
Please also provide your single-phase motor manual. We need the wiring diagram of the motor for further confirmation. Thank you for your understanding.
We need help with single phase VFD
5
tzivia
Avatar
6/15/2023 8:22 PM
We need help with E01 code on a gk3000 1s0022g 2.2 kw connected to a 3hp 220v 1 phase in and out. The manual send does not match.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, we can not find your order number, please provide us with the order number and your motor nameplate picture for further confirmation. We hope to provide you with better service. What is the load on your motor?
The E01 code is caused by VFD accelerated running over-current, you can try setting:
1. Please extend the acceleration and deceleration time. (set parameter P0.17)
2. Please adjust the V/F curve.(set parameter P0.22=2 or 3)
3. If the VFD power is too small, you need to replace it with a higher power one.
How do I get VFD to run in constant pressure mode?
5
blanche
Avatar
7/20/2023 8:26 PM
Had to change the pump which is run by the 2.2kw GK3000 single-phase VFD and now it is not going into constant pressure mode.  It runs to the set pressure and goes to hibernate frequency for a period of time and shuts off.  Starts back up at low revival pressure and repeats the cycle.
How do I get it to run in constant pressure mode again?
I cannot change this variable:  P7.05.  
How do I change it?  
It currently appears to change based on P7.08 and P7.09

P7.00     1
P7.05     340 or 200 toggles between the two numbers (will not change)
P7.19     225
P7.20     340
P7.26     1
P7.27     950
Was this review helpful? Yes No (0/0)
ATO Responded
If you don’t need the sleep pressure function, please set the sleep pressure position P7.20=P7.05 (set pressure 340 or 200), P7.22=0 (sleep frequency), and test again
VFD sleep frequency setting
5
logan
Avatar
7/20/2023 9:54 PM
I need a sleep frequency as the pump will not flow below the set value.
What triggers the vfd to go into continuous pressure mode vs going to sleep mode?
Was this review helpful? Yes No (0/0)
ATO Responded
If you want the continuous pressure mode, you can only remove the sleep pressure.
If you want the sleep pressure, then set the sleep pressure, the two are not compatible at the same time, you can only choose one.
Sleep pressure means that after the actual pressure reaches the set pressure, the VFD will enter sleep mode and stop running.
When the pressure drops to the sleep pressure, the VFD will automatically restart until the set pressure is reached again.
Question on connectiion
5
Kristen
Avatar
10/17/2023 12:44 AM
Where do I find The L1 &L2 connection ? there is no connection to suite top or middle.
Was this review helpful? Yes No (0/0)
ATO Responded
Are the L1 and L2 you are talking about the power connections for the VFD input? The VFD input terminal can be connected to the R and S terminals, please refer to the attached picture.
About installation
4
Zackn
Avatar
7/15/2024 2:58 AM
After purchasing your ATO single phase input/output VFD 3hp unit, I am finally going to install it. Turn off the phase loss protection: set PA=0; I assume this is still required?
I would like to keep the capacitors, so my input power 240VAC goes to L1 & L2 with the output going to the motor via U & V or V & W with E for ground. Is this correct? I would like to run the motor at approximately 300-500 rpm without damaging the motor. Is this OK?
Was this review helpful? Yes No (0/0)
ATO Responded
1. You still need to turn off the phase loss protection: set PA.13=0; Since your motor is a single-phase motor, we do not recommend running the motor below 40Hz for a long time, otherwise the single-phase motor will easily heat up.
2. Regarding VFD wiring: Yes, your input power 240VAC goes to L1 & L2 with the output going to the motor via U & V or V & W with E for ground. Please free to contact us if you have other questions.
The parameters for the drive restart
5
Lorenzo
Avatar
11/21/2024 1:30 AM
What are the parameters for the drive restart after power loss?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD does not have a power-off restart parameter. If you use the terminal control start, the power is cut off and then restored when the terminal is closed, and the VFD will run if the terminal is still closed.
I'm having trouble Installing my VFD
4
Lindor
Avatar
2/27/2025 12:39 AM
I'm trying to install it on a Leeson 3hp single phase motor 230V input with run/start capacitors. When I installed it the motor just rock back and forward not making 1 compete turn so I'm thinking that I Program it wrong but I cannot find ANYTHING to tell me how to do a factory reset.
So, we left that one alone and we try to install it on a different motor a Rockwell same size and output as the Leeson. This time it ran but we burn out the start capacitors I am an electrician but I have never installed a VFD before I feel that I have it wired right.
Was this review helpful? Yes No (0/0)
ATO Responded
First of all, the forward and reverse rotation of the single-phase motor can only be achieved by changing the motor wiring method. And the forward and reverse rotation can Not be changed directly through the VFD (only three-phase motors can).
In addition, the wiring of the single-phase motor can maintain the capacitor wiring method, but the motor can Not run at low speed and low frequency. We recommend running the single-phase motor above 40HZ, otherwise the running capacitor will heat up and be damaged. This is determined by the principle of the single-phase motor.
So, if you want to adjust the motor speed, you need to change to a three-phase motor. For the wiring and use of single-phase motors, refer to this video: https://www.youtube.com/watch?v=jiVpJAY84MQ&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=5
Only registered users can write reviews
Customers who bought this item also bought

2 hp (1.5 kW) VFD, Single Phase Input & Output

GK3000-1S0015
$243.08
Discounted 2 hp VFD, 1 phase for single phase AC motor, 220V - 240V 9.6 amps, brand new direct sale by manufacturer.

10K Ohm Rotary Potentiometer with On Off Switch

ATO-RP-10K
$17.86
Buy low priced variable rotary potentiometers with 10K Ohm resistance from ATO.com. This on/off rotary switch potentiometer is widely used for audio, guitar, amplifiers, electric lights, other arduino based two tone device projects and more.

Pressure Sensor for Air/Water/Oil, 4-20mA/RS485/0-5V/0-10V Output

ATO-PRES-P300S
$119.68
Low-range pressure sensor provides 0–10/20/50/100 kPa, -100–0 kPa and -100–100 kPa options with current, voltage or RS485 outputs. Designed for low-pressure and vacuum/compound pressure measurement of air, water and oil, with flexible 12V, 24V or 12–36V DC power supply.

5 hp (4 kW) VFD, Single Phase Input & Output

GK3000-1S0037
$649.54
Low cost 5 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 25 amps, manufacturer direct sale.

7.5 hp (5.5 kW) VFD, Single Phase Input & Output

GK3000-1S0055
$996.85
Favorable price 7.5 hp VFD, 1 phase for single phase AC induction motor, high variable speed performance, 220V - 240V 32 amps, manufacturer direct sale.