2 hp (1.5 kW) VFD, Single Phase Input & Output

$243.08
Discounted 2 hp VFD, 1 phase for single phase AC motor, 220V - 240V 9.6 amps, brand new direct sale by manufacturer.
SKU: GK3000-1S0015
Availability: In stock
Free Shipping
Delivery date: 2-3 days

2 hp variable frequency drive, 1.5 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0015
Capacity2 hp (1.5 kW)
Shipping weight2 kg
Dimension190*104*150 mm
I/O FeatureRated current9.6 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

1500W Single Phase VFD Details

Tips: Variable frequency drive dust cleaning attentions
In actual operation of the variable frequency drive, the device will always be affected by the environment, such as temperature, humidity, air quality and so on. Especially in the dusty production workshops, if not timely clean up the dust, the operation of the VFD will have a certain impact, or seriously lead to some problems. In the process of dust removal of VFD, there are something need to pay attention:

  1. Each VFD needs to be dust cleaned once a season.
  2. Shutdown the VFD before cleaning, and wait for the voltage down to the safety then start working.
  3. First use brush to clean the dust on the surface of the VFD, but pressure fan is not recommended for the cleaning.
  4. If the VFD surface is greasy, use a small amount of alcohol to wipe clean, and must wait for the VFD dried before booting again.
  5. In the maintenance, carefully check whether there are hot discolor parts, whether there is cracking of the cement resistance, or whether the electrolytic capacitors has expansion of leakage hole, protruding holes and other phenomena.
  6. If possible, remove the shell and use compressed air to blow out the dust inside the VFD and in the wind path. Pay attention when using compressed air because it may contain large amount of moisture. Using a vacuum cleaner is better than compressed air, because the moisture in the compressed air may cause error to the VFD.

Running a single phase motor with VFD

In this video, ATO will show you details about running a single phase motor on a VFD. It's important to note that there are two wiring methods for single phase motor connecting to ATO single phase VFD: wiring of removing motor capacitor & wiring of keeping motor capacitor. At first, you should choose the wiring method you needed, and then set basic parameters step by step.

Four Ways to Control VFD with PLC

This video introduces the main wiring methods between PLC and VFD, including digital control, analog control, serial communication and Ethernet connection. The choice of connection method depends on the specific application requirements, system complexity, cost considerations and the need for control accuracy and flexibility.

How to Choose a VFD for Your Motor?

In this video, we lay out a list of key factors that should guide you in choosing the right VFD for your motor or any other possible application.

VFD analog input 0-10V frequency control (VI port)

Single-phase Output VFD Controls Single-phase Motor Speed

This video shows the details of using a frequency converter to run a single-phase motor on a single-phase power supply. Including wiring, parameter setting, single-phase motor speed control, etc.

Product reviews
High Quality
5
Redneck
Avatar
3/20/2019 2:08 AM
This 2hp single phase VFD was bought for my belt grinders. This product is sealed up so that no dust gets inside, which makes it suitable for rugged environment. It's easy to install and no programming requirements. What's more, this unit works well, provides good soft start, and realizes variable speed control. High quality and recommend.
Was this review helpful? Yes No (3/0)
Can 2hp VFD be delivered the earliest?
5
Wass
Avatar
3/28/2021 7:28 PM
Can you suggest the earliest delivery of 2HP 1-phase VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
It can be delivered within 5 to 6 days because it needs to be well tested before shipment.
2 hp VFD using current
5
Robinson
Avatar
4/29/2021 8:19 PM
Can I use your 2 hp 1 phase drive on a single phase AC 220V-230V blower motor to control the motor speed?
Was this review helpful? Yes No (1/0)
ATO Responded
Yes, it can as long as your motor rated current is less than 7.5A.
2 hp VFD can withstand voltage
5
Elmer
Avatar
6/3/2021 11:56 PM
For your GK3000-1S0015 and GK3000-1S0007 1 phase drive, will these take 208v without any issues?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course. It can take 208/220/230/240V with no problem.
Reliable 2hp (1.5kW) VFD
5
Groove
Avatar
6/22/2021 9:14 PM
I need adrive for my 2HP motor, why would it not be GK3000-1S0015? Which is listed for 2HP?
Was this review helpful? Yes No (0/0)
ATO Responded
You should have a margin of at 10-20%. So GK3000-1S0022 (3HP) will be more reliable.
Can you provide a wire diagram for this application?
5
Drew
Avatar
6/27/2022 3:28 AM
I'm installing this VFD on my well pump and using it as a soft start to reduce the impact to my batteries on my solar system. When I wire it in do I still use my Franklin Electric control box with the capacitor or does that get replaced with he VFD? I have a 3 wire 1/2 hp pump, can you provide a wire diagram for this application?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The single-phase motor can be connected to the VFD without removing the capacitor. The two wires of the motor are directly connected to any two of the U, V, and W terminals of the VFD.
2. If you want to use VFD for constant pressure water supply, you could refer to our video. Please see on <[5UQ[BL(6~BS2JV6W}N6[%S.png>https://www.youtube.com/watch?v=OKR4tX4x0qQ&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=5
How do I set the controller to reverse?
5
Christopher
Avatar
1/3/2023 11:45 PM
How can I control the direction of the motor with the control panel rather than installing some switches to the com port? The controller shows a jog/rev button, but it seems to only jog the motor.
Was this review helpful? Yes No (0/0)
ATO Responded
The single-phase VFD cannot control the reverse rotation of the motor. Please refer to the motor nameplate for reverse wiring.
Well pump controller
5
Randy
Avatar
2/11/2023 4:52 PM
I have a Goulds 13GS10412CL submersible pump and I see that it is compatible with variable speed controller. It is 1.0 HP 60 Hz FLA 8.1 SFA 9.4 single phase. What do you recommend as far as VFD to make it constant pressure supply? I would like to use a psi transducer also.
Was this review helpful? Yes No (0/0)
Which terminal of VFD will send the signal VFD fault feedback to our PLC?
5
Rokyd
Avatar
3/6/2023 1:32 AM
For the GK3000 series, which terminal of VFD will send the signal VFD fault feedback to our PLC? any? So we can disconnect the circuit to VFD, and show the alarm indicator on the our HMI Display
Was this review helpful? Yes No (0/0)
ATO Responded
The TA TB terminal of VFD can feed back the fault signal of VFD to PLC.
The pressure switch on the compressor is normally closed
5
Alob
Avatar
3/22/2023 1:32 AM
I have a question about my VFD. The pressure switch on the compressor is normally closed (NC). What happened?
Was this review helpful? Yes No (0/0)
ATO Responded
If the pressure switch on the compressor is normally closed (NC) , then this pressure switch cannot be used directly. Could you please tell us how you want to control the start and stop of the VFD through this pressure switch, and what is the process?
2hp
5
Pedro
Avatar
5/6/2023 6:04 AM
good morning, I have a 220v 2hp 1440rpm single-phase motor to which I want to install a frequency inverter to control the speed, this inverter; GK3000-1S0015, would it work for me?
Thank you and I await your comments
Was this review helpful? Yes No (0/0)
ATO Responded
To confirm whether VFD can drive your motor, you need to know: VFD power is greater than or equal to motor power, and VFD current is greater than or equal to motor current. For the speed regulation of single-phase motor, we recommend that the running speed of the motor is greater than 80% of the rated speed.
A VFD for a drill press
5
Maisara
Avatar
5/23/2023 9:48 AM
Hi,
I was wondering if I can use this VFD to drive my drill press 750w permanent split capacitor motor.
I have no idea about how I should connect the motor, my main concern is to control the speed of the motor with keeping the torque. Also, I was wondering if it is possible to control the rotation of the motor and adding external switches and potentiometers. Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Single-phase VFDs have a small starting torque when controlling single-phase motors. If you want constant torque or high torque starting and speed regulation operation, ATO suggests you replace your single-phase (split-phase) motor with a three-phase motor. Also, the current and power rating of the VFD must be greater than or equal to the current and power rating of the motor.
Is there any problem of VFD?
5
heard
Avatar
7/20/2023 9:15 PM
2 capacitors are available in the engine start and permanent capacitor is this a problem?
Is there any problem?
Was this review helpful? Yes No (0/0)
ATO Responded
Please describe your problem carefully.
If it is a single-phase motor, we do not recommend removing the capacitor, nor do we recommend that the single-phase motor run at low speed for a long time.
Which VFD input should I connect the winding cable end to?
5
sita
Avatar
7/21/2023 1:25 AM
I want to make sure before I buy.
After the engine capacitors are removed, it does not work with the starting load without auxiliary winding, which input should I connect the auxiliary winding cable end to?
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to page P41 of the manual for how to remove the capacitor and reconnect it: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
Is there a box available for connecting?
5
Jakko
Avatar
8/9/2023 12:16 AM
When installing the VFDs today the electrician said there needs to be a junction box on the VFD where they can connect the conduit for the wires or the VFDs will need to be installed in a cabinet. Is there a box available for connecting conduit that can attach to the VFD or will they need to be installed in a cabinet?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD is usually installed in a cabinet with good ventilation and heat dissipation. Unfortunately, we do not provide the corresponding junction box.  You need to configure the junction box or cabinet yourself.
Hello
5
Hesham
Avatar
10/3/2023 6:19 AM
I want to use this VFD to change frequency of pumps, the nominal current for pumps (two models) are, 6.1 and 8.3 Amps. Which models should I choose?

The pumps rated at 1.1
Was this review helpful? Yes No (0/0)
ATO Responded
You can use the 1.5kW VFD on this page, or go to the 2kW VFD page to purchase.
Hello
5
Mavis
Avatar
10/16/2023 2:47 AM
Hello,
We are in need of assistance setting up a VFD.
Sequence will be, VFD receives start stop signal and drives to constant speed, no modulating. Need N/O status contacts. Also would like to have dry contact for enabling a relay for a damper.

1) Where do we wire start/stop and how is it programmed?

2) Where do we wire dry contact status? Needs to be N/O and close when fan starts.

3) We would like to have a contact closure to control a damper actuator. Can this be accomplished with Ta, Tb and Tc contacts? When fan starts a contact would close.
Was this review helpful? Yes No (0/0)
ATO Responded
1. You can use the three-wire control mode of our VFD (Note: this method only applies to 3-phase motors).
Please refer to the video link for connection and settings: https://www.youtube.com/watch?v=nBUm4i9wnzY
As demonstrated in the video, to achieve the switch control function of starting and stopping the VFD that you need, you need to perform the following program settings:
1).Set P0.03 = 1, terminal control mode
2).Set P4.02 = 9, enable terminal X3 as 3-wire control
3).Set P4.08 = 2, select 3-wire control mode 1
Please refer to the wiring diagram of manual P115 in the attachment. Unnecessary control wires do Not need to be connected.

2. Regarding the relay output, please refer to P32 and P116~P117 of the manual in the attachment.
You can connect TA and TB to get N/O output, and set P4.12 = 0 (flip when inverter is in RUN state)
The VFD's relay output can also be configured to flip under other circumstances, please see manual P116~P117.
I am having issues
5
joseph
Avatar
11/23/2023 7:52 PM
I am having issues programming the GK3000 VFD.  I am wiring a 240Vac 60hz, 1PH fan motor and I keep getting alarms E-01 and occasionally E-03.  What can I adjust to get the frequency drive working?
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD appears to be undercapacity and overloaded.You can extend the acceleration and deceleration time, modify the following parameters, and test again:
P0.12=10 or 12 (Acceleration time; you may change the time)
P0.13=10 or 12 (Deceleration time; you may change the time)
PA.01=5 (motor overload protection gain)
PA,02=100% (motor overload protection coefficient)
If you still have problems, please send us a picture of the nameplate of the VFD and fan for further confirmation. Maybe you need to replace it with a larger VFD.
VFD
5
Andrew
Avatar
11/23/2023 11:20 PM
Since we are not going to run the fan with full speed power (actually it will only use about 50%), we chose this VFD. Also, the input power supply that I provide is single-phase 220VAC, and we exactly connected the wires as the attached diagram. Also, we could not see any errors when the VFD is running since when we give the power, the lcd panel shows up for few seconds and then fuse blows.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Your fan is a single-phase motor. It is not recommended to run a single-phase motor at low speed. The speed should be kept above 35% of the rated speed. If the speed is too low, the motor can easily overheat and burn out.
2. Where did the fuse you mentioned burnt out? Please provide us with pictures or videos for further confirmation.You can send us the large video file via wetransfer.com.
The motor cannot spin
5
Hollis
Avatar
9/24/2024 12:05 AM
We have purchased a VFD GK3000-1S0015G. I cannot get the Motor to spin. I have connected output power from VFD. I have set output current to10 amps. I cannot set the motor power parameter P8.01 more than 1000. P8.37=0 cannot change. I get an error E-01. I have set: P0.12=100. Torque boost seems to have no affect.
Was this review helpful? Yes No (0/0)
ATO Responded
E-01 means the VFD is overloaded. Your single-phase motor is 2HP 1.5kW, rated current 9.6A, and the VFD you purchased is also 2HP, rated output current is only 9.6A. In this case, the VFD is easily overloaded. Generally, the capacity of the VFD is one level larger than the motor capacity. We recommend that you change to a 3HP capacity, SKU: GK3000-1S0022, see spec and price on: https://www.ato.com/3hp-vfd-single-phase-input-output.
GK3000 - Single Phase Pump Install
5
ULRICH
Avatar
9/2/2025 1:39 AM
We installed the GK3000 to 1.5kW motor.
The motor runs but gets very hot and trips on E01.
The motor had Start Cap and Run Caps. These have been removed.
Input current will sometimes exceed 14A.
The pump at 50Hz will not get to maximum output.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can contact us at sales@ato.com or service@ato.com and describe your problem in detail. We will provide you with a solution.
Single phase 240 input/ three phase output.
5
David
Avatar
11/20/2025 4:14 PM
Is there a guide for setting parameters for supplying a 220 3 phase milling machine with a 2 HP VFD? I am having trouble getting the frequency to go up to 60 HRZ. It comes from the factory with a 50 HRZ setting. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
Set P0.02=60, P0.05=60, P0.06=60, P8.04=60. Refer to the quick setup manual: https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

2 hp variable frequency drive, 1.5 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0015
Capacity2 hp (1.5 kW)
Shipping weight2 kg
Dimension190*104*150 mm
I/O FeatureRated current9.6 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

1500W Single Phase VFD Details

Tips: Variable frequency drive dust cleaning attentions
In actual operation of the variable frequency drive, the device will always be affected by the environment, such as temperature, humidity, air quality and so on. Especially in the dusty production workshops, if not timely clean up the dust, the operation of the VFD will have a certain impact, or seriously lead to some problems. In the process of dust removal of VFD, there are something need to pay attention:

  1. Each VFD needs to be dust cleaned once a season.
  2. Shutdown the VFD before cleaning, and wait for the voltage down to the safety then start working.
  3. First use brush to clean the dust on the surface of the VFD, but pressure fan is not recommended for the cleaning.
  4. If the VFD surface is greasy, use a small amount of alcohol to wipe clean, and must wait for the VFD dried before booting again.
  5. In the maintenance, carefully check whether there are hot discolor parts, whether there is cracking of the cement resistance, or whether the electrolytic capacitors has expansion of leakage hole, protruding holes and other phenomena.
  6. If possible, remove the shell and use compressed air to blow out the dust inside the VFD and in the wind path. Pay attention when using compressed air because it may contain large amount of moisture. Using a vacuum cleaner is better than compressed air, because the moisture in the compressed air may cause error to the VFD.
Product reviews
High Quality
5
Redneck
Avatar
3/20/2019 2:08 AM
This 2hp single phase VFD was bought for my belt grinders. This product is sealed up so that no dust gets inside, which makes it suitable for rugged environment. It's easy to install and no programming requirements. What's more, this unit works well, provides good soft start, and realizes variable speed control. High quality and recommend.
Was this review helpful? Yes No (3/0)
Can 2hp VFD be delivered the earliest?
5
Wass
Avatar
3/28/2021 7:28 PM
Can you suggest the earliest delivery of 2HP 1-phase VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
It can be delivered within 5 to 6 days because it needs to be well tested before shipment.
2 hp VFD using current
5
Robinson
Avatar
4/29/2021 8:19 PM
Can I use your 2 hp 1 phase drive on a single phase AC 220V-230V blower motor to control the motor speed?
Was this review helpful? Yes No (1/0)
ATO Responded
Yes, it can as long as your motor rated current is less than 7.5A.
2 hp VFD can withstand voltage
5
Elmer
Avatar
6/3/2021 11:56 PM
For your GK3000-1S0015 and GK3000-1S0007 1 phase drive, will these take 208v without any issues?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course. It can take 208/220/230/240V with no problem.
Reliable 2hp (1.5kW) VFD
5
Groove
Avatar
6/22/2021 9:14 PM
I need adrive for my 2HP motor, why would it not be GK3000-1S0015? Which is listed for 2HP?
Was this review helpful? Yes No (0/0)
ATO Responded
You should have a margin of at 10-20%. So GK3000-1S0022 (3HP) will be more reliable.
Can you provide a wire diagram for this application?
5
Drew
Avatar
6/27/2022 3:28 AM
I'm installing this VFD on my well pump and using it as a soft start to reduce the impact to my batteries on my solar system. When I wire it in do I still use my Franklin Electric control box with the capacitor or does that get replaced with he VFD? I have a 3 wire 1/2 hp pump, can you provide a wire diagram for this application?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The single-phase motor can be connected to the VFD without removing the capacitor. The two wires of the motor are directly connected to any two of the U, V, and W terminals of the VFD.
2. If you want to use VFD for constant pressure water supply, you could refer to our video. Please see on <[5UQ[BL(6~BS2JV6W}N6[%S.png>https://www.youtube.com/watch?v=OKR4tX4x0qQ&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=5
How do I set the controller to reverse?
5
Christopher
Avatar
1/3/2023 11:45 PM
How can I control the direction of the motor with the control panel rather than installing some switches to the com port? The controller shows a jog/rev button, but it seems to only jog the motor.
Was this review helpful? Yes No (0/0)
ATO Responded
The single-phase VFD cannot control the reverse rotation of the motor. Please refer to the motor nameplate for reverse wiring.
Well pump controller
5
Randy
Avatar
2/11/2023 4:52 PM
I have a Goulds 13GS10412CL submersible pump and I see that it is compatible with variable speed controller. It is 1.0 HP 60 Hz FLA 8.1 SFA 9.4 single phase. What do you recommend as far as VFD to make it constant pressure supply? I would like to use a psi transducer also.
Was this review helpful? Yes No (0/0)
Which terminal of VFD will send the signal VFD fault feedback to our PLC?
5
Rokyd
Avatar
3/6/2023 1:32 AM
For the GK3000 series, which terminal of VFD will send the signal VFD fault feedback to our PLC? any? So we can disconnect the circuit to VFD, and show the alarm indicator on the our HMI Display
Was this review helpful? Yes No (0/0)
ATO Responded
The TA TB terminal of VFD can feed back the fault signal of VFD to PLC.
The pressure switch on the compressor is normally closed
5
Alob
Avatar
3/22/2023 1:32 AM
I have a question about my VFD. The pressure switch on the compressor is normally closed (NC). What happened?
Was this review helpful? Yes No (0/0)
ATO Responded
If the pressure switch on the compressor is normally closed (NC) , then this pressure switch cannot be used directly. Could you please tell us how you want to control the start and stop of the VFD through this pressure switch, and what is the process?
2hp
5
Pedro
Avatar
5/6/2023 6:04 AM
good morning, I have a 220v 2hp 1440rpm single-phase motor to which I want to install a frequency inverter to control the speed, this inverter; GK3000-1S0015, would it work for me?
Thank you and I await your comments
Was this review helpful? Yes No (0/0)
ATO Responded
To confirm whether VFD can drive your motor, you need to know: VFD power is greater than or equal to motor power, and VFD current is greater than or equal to motor current. For the speed regulation of single-phase motor, we recommend that the running speed of the motor is greater than 80% of the rated speed.
A VFD for a drill press
5
Maisara
Avatar
5/23/2023 9:48 AM
Hi,
I was wondering if I can use this VFD to drive my drill press 750w permanent split capacitor motor.
I have no idea about how I should connect the motor, my main concern is to control the speed of the motor with keeping the torque. Also, I was wondering if it is possible to control the rotation of the motor and adding external switches and potentiometers. Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Single-phase VFDs have a small starting torque when controlling single-phase motors. If you want constant torque or high torque starting and speed regulation operation, ATO suggests you replace your single-phase (split-phase) motor with a three-phase motor. Also, the current and power rating of the VFD must be greater than or equal to the current and power rating of the motor.
Is there any problem of VFD?
5
heard
Avatar
7/20/2023 9:15 PM
2 capacitors are available in the engine start and permanent capacitor is this a problem?
Is there any problem?
Was this review helpful? Yes No (0/0)
ATO Responded
Please describe your problem carefully.
If it is a single-phase motor, we do not recommend removing the capacitor, nor do we recommend that the single-phase motor run at low speed for a long time.
Which VFD input should I connect the winding cable end to?
5
sita
Avatar
7/21/2023 1:25 AM
I want to make sure before I buy.
After the engine capacitors are removed, it does not work with the starting load without auxiliary winding, which input should I connect the auxiliary winding cable end to?
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to page P41 of the manual for how to remove the capacitor and reconnect it: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
Is there a box available for connecting?
5
Jakko
Avatar
8/9/2023 12:16 AM
When installing the VFDs today the electrician said there needs to be a junction box on the VFD where they can connect the conduit for the wires or the VFDs will need to be installed in a cabinet. Is there a box available for connecting conduit that can attach to the VFD or will they need to be installed in a cabinet?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD is usually installed in a cabinet with good ventilation and heat dissipation. Unfortunately, we do not provide the corresponding junction box.  You need to configure the junction box or cabinet yourself.
Hello
5
Hesham
Avatar
10/3/2023 6:19 AM
I want to use this VFD to change frequency of pumps, the nominal current for pumps (two models) are, 6.1 and 8.3 Amps. Which models should I choose?

The pumps rated at 1.1
Was this review helpful? Yes No (0/0)
ATO Responded
You can use the 1.5kW VFD on this page, or go to the 2kW VFD page to purchase.
Hello
5
Mavis
Avatar
10/16/2023 2:47 AM
Hello,
We are in need of assistance setting up a VFD.
Sequence will be, VFD receives start stop signal and drives to constant speed, no modulating. Need N/O status contacts. Also would like to have dry contact for enabling a relay for a damper.

1) Where do we wire start/stop and how is it programmed?

2) Where do we wire dry contact status? Needs to be N/O and close when fan starts.

3) We would like to have a contact closure to control a damper actuator. Can this be accomplished with Ta, Tb and Tc contacts? When fan starts a contact would close.
Was this review helpful? Yes No (0/0)
ATO Responded
1. You can use the three-wire control mode of our VFD (Note: this method only applies to 3-phase motors).
Please refer to the video link for connection and settings: https://www.youtube.com/watch?v=nBUm4i9wnzY
As demonstrated in the video, to achieve the switch control function of starting and stopping the VFD that you need, you need to perform the following program settings:
1).Set P0.03 = 1, terminal control mode
2).Set P4.02 = 9, enable terminal X3 as 3-wire control
3).Set P4.08 = 2, select 3-wire control mode 1
Please refer to the wiring diagram of manual P115 in the attachment. Unnecessary control wires do Not need to be connected.

2. Regarding the relay output, please refer to P32 and P116~P117 of the manual in the attachment.
You can connect TA and TB to get N/O output, and set P4.12 = 0 (flip when inverter is in RUN state)
The VFD's relay output can also be configured to flip under other circumstances, please see manual P116~P117.
I am having issues
5
joseph
Avatar
11/23/2023 7:52 PM
I am having issues programming the GK3000 VFD.  I am wiring a 240Vac 60hz, 1PH fan motor and I keep getting alarms E-01 and occasionally E-03.  What can I adjust to get the frequency drive working?
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD appears to be undercapacity and overloaded.You can extend the acceleration and deceleration time, modify the following parameters, and test again:
P0.12=10 or 12 (Acceleration time; you may change the time)
P0.13=10 or 12 (Deceleration time; you may change the time)
PA.01=5 (motor overload protection gain)
PA,02=100% (motor overload protection coefficient)
If you still have problems, please send us a picture of the nameplate of the VFD and fan for further confirmation. Maybe you need to replace it with a larger VFD.
VFD
5
Andrew
Avatar
11/23/2023 11:20 PM
Since we are not going to run the fan with full speed power (actually it will only use about 50%), we chose this VFD. Also, the input power supply that I provide is single-phase 220VAC, and we exactly connected the wires as the attached diagram. Also, we could not see any errors when the VFD is running since when we give the power, the lcd panel shows up for few seconds and then fuse blows.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Your fan is a single-phase motor. It is not recommended to run a single-phase motor at low speed. The speed should be kept above 35% of the rated speed. If the speed is too low, the motor can easily overheat and burn out.
2. Where did the fuse you mentioned burnt out? Please provide us with pictures or videos for further confirmation.You can send us the large video file via wetransfer.com.
The motor cannot spin
5
Hollis
Avatar
9/24/2024 12:05 AM
We have purchased a VFD GK3000-1S0015G. I cannot get the Motor to spin. I have connected output power from VFD. I have set output current to10 amps. I cannot set the motor power parameter P8.01 more than 1000. P8.37=0 cannot change. I get an error E-01. I have set: P0.12=100. Torque boost seems to have no affect.
Was this review helpful? Yes No (0/0)
ATO Responded
E-01 means the VFD is overloaded. Your single-phase motor is 2HP 1.5kW, rated current 9.6A, and the VFD you purchased is also 2HP, rated output current is only 9.6A. In this case, the VFD is easily overloaded. Generally, the capacity of the VFD is one level larger than the motor capacity. We recommend that you change to a 3HP capacity, SKU: GK3000-1S0022, see spec and price on: https://www.ato.com/3hp-vfd-single-phase-input-output.
GK3000 - Single Phase Pump Install
5
ULRICH
Avatar
9/2/2025 1:39 AM
We installed the GK3000 to 1.5kW motor.
The motor runs but gets very hot and trips on E01.
The motor had Start Cap and Run Caps. These have been removed.
Input current will sometimes exceed 14A.
The pump at 50Hz will not get to maximum output.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, you can contact us at sales@ato.com or service@ato.com and describe your problem in detail. We will provide you with a solution.
Single phase 240 input/ three phase output.
5
David
Avatar
11/20/2025 4:14 PM
Is there a guide for setting parameters for supplying a 220 3 phase milling machine with a 2 HP VFD? I am having trouble getting the frequency to go up to 60 HRZ. It comes from the factory with a 50 HRZ setting. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
Set P0.02=60, P0.05=60, P0.06=60, P8.04=60. Refer to the quick setup manual: https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf
Only registered users can write reviews
Customers who bought this item also bought

1 hp (0.75 kW) VFD, Single Phase Input & Output

GK3000-1S0007
$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.

3 hp (2.2 kW) VFD, Single Phase Input & Output

GK3000-1S0022
$379.23
Cheap 3 hp VFD, 1 phase for single phase AC induction motor, good variable speed performance, 220V - 240V 17 amps, manufacturer direct sale.

3 hp (2.2 kW) AC Line Reactor, 3 Phase Output

ATO-OLR-2d2
$244.54
The 3-phase AC output line reactor material has copper and aluminum for choice, line reactor for vfd. The insulation rank is class F,H, voltage choose from 220V, 380V, 400V, 410V, 440V, 460V or 480V. Low cost, well-made and widely used.

Digital Pressure Sensor for Hydraulic/Steam/Air

ATO-PRES-PX300
$173.33
Digital pressure sensor covers -0.1 to 100 MPa and supports 4–20mA, 0–20mA, voltage and RS485 outputs, with a backlit LCD display. Suitable for hydraulic, steam, air and liquid pressure measurement, with medium temperatures from -40°C to 60°C.

1 hp (750W) 1-phase/3-Phase AC Gear Motor, Ratio 3~100

ATO-GEAR-HV750
$811.69
Good price 3-phase AC gear motor works at 1 hp rated power, gear ratio 3:1~100:1 for selection, torque 1.1~43.2 kg.m, shaft diameter 28mm/32mm, power supply 1-phase/3-phase 110V/220V/380V, horizontal/vertical installation. 750W electric gear motor can operated with a 90V brake to control power cutting.