Sheath thermocouple have shielded thermocouple wire of common length 500mm and sheath diameter Ф3~Φ8mm, with flexibility, high pressure resistant, fast thermal response time and long operating life. J type thermocouple can directly measure the temperature of liquid, vapor, gas medium and solid surface in the range of 0~600 ℃ in various production processes, especially in vacuum, oxidation, reduction or inert atmosphere.
SKU: ATO-TC-JS
*
This product has a minimum quantity of 2
Free Shipping
Delivery date: 6-12 days

As a temperature sensor, thermocouple is usually used with display instruments, recording instruments and signal conditioners. Sheath thermocouple also can be used as a temperature sensing element for assembly thermocouple.

Specification

1. S/E/K/J/T type thermocouple temperature range and accuracy chart

CategoryType of sensing elementSheath diameterNormal working temperatureHighest working temperatureAllowable deviation Δt
Measuring rangePermissible deviation
Platinum Rhodium 10 - PlatinumS type≥Φ3mm1100℃1300℃0~1300℃±2.5℃ or ±0.75%t
Nickelchromium - Copper nickelE type≥Φ3mm600℃700℃0~700℃±2.5℃ or ±0.75%t
Nickel chromium - Nickel siliconK type≥Φ3mm800℃950℃0~900℃±2.5℃ or ±0.75%t
Iron - constantanJ type≥Φ3mm500℃600℃0~600℃Not specified
Copper - Copper nickelT type≥Φ3mm350℃400℃<-200℃Not specified
-40~350℃±1.0℃ or ±0.75%t

2. Thermal response time of thermocouple

Sheath diameter (mm)

Thermal response time (s)
Shell typeInsulation type
2.00.40.5
3.00.61.2
4.00.82.5
5.01.24.0
6.02.06.0
8.04.08.0

3. Thermocouple wire structure chart
Thermocouple wire structure chart
4. Selection chart

Branch numberInstalling formMode of connectionWorking end formMultipoint typeAdditional deviceSheath diameterSheath length
B1: Single branch;
B2: Double branch
I1: No fixed device;
I2: Fixed card sets of thread joint;
I3: Movable card sets of thread joint;
I4: Fixed card sets of flange;
I5: Movable card sets of flange
C0: Simple terminals;
C3: Standard waterproof protection head;
C4: Explosion-proof protection head;
C5: Standard plug;
C6: Aviation plug;
C7: Handheld;
C8: Small waterproof protection head;
C9: Direct lead wire
W1: Insulation type;
W2: Shell type;
W3: Open end type
M3: 3 points;
M4: 4 points;
M5: 5 points;
M6: 6 points
S: Sanitary chuck;
H: Heat collector
D3: Φ3;
D4: Φ4;
D5: Φ5;
D6: Φ6;
D8: Φ8
Φ3: 50~15000mm;
Φ4: 50~10000mm;
Φ5: 50~4000mm;
Φ6: 50~2000mm;
Φ8: 50~1000mm

5. Thermocouple installation diagram
Thermocouple installation diagram

Feature

  • High Mechanical Strength: Strong structure with good pressure resistance, suitable for harsh industrial environments.
  • Flexible Installation: Can be bent for curved or space-limited mounting scenarios, enhancing installation convenience.
  • Wide Measurement Range: Sheath thermocouple suitable for various temperature ranges in industrial and laboratory use.
  • Fast Thermal Response: Minimizes dynamic error with rapid response to temperature changes.
  • Leak-Proof Insulated Connector: Designed with anti-electric-leakage plastic molding, crafted through multiple precise processes for safety and reliability.
  • Premium Plastic Components: Quality plastic materials offer durability and insulation.
    Comfortable Handle Design: Ergonomically shaped grip for safe and easy handling.

Tips: How to prevent interference for thermocouple?

  1. Isolation
    Isolation method is to hang thermocouple in the air to isolate thermocouple from refractory brick of furnace wall, and thermocouple is also isolated from support by use of insulation object. The method can prevent interference of high temperature electric leakage.
  2. Shielding
    Shielding method is to make extension wire of thermocouple pass through iron tube or other metal shields to isolate. In this way, it can prevent electromagnetic interference and interference of high voltage electric field. When using this method, iron tube and shields should be connected with the ground well and twist the extension wire as well.
  3. Ground connection
    This method has two forms: The first is to connect the reference end of thermocouple with the ground, and second is to connect the measurement end of thermocouple with the ground.

1. Cast set of thread joint

Clip sleeve threaded joint dimension

Armoured thermocoupleΦ8Φ6Φ5(Φ4)Φ4Φ3Φ2 and below
Fixing device number and size (mm)
MM16*1.5M12*1.5
S2219

2. Sleeve flange

Sleeve flange

Armoured thermocoupleΦ8Φ6Φ5(Φ4)Φ4Φ3Φ2 and below
Fixing device number and size (mm)
DΦ60Φ50
D0Φ42Φ36
D1Φ24Φ20
S2219
d0Φ9Φ7
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

As a temperature sensor, thermocouple is usually used with display instruments, recording instruments and signal conditioners. Sheath thermocouple also can be used as a temperature sensing element for assembly thermocouple.

Specification

1. S/E/K/J/T type thermocouple temperature range and accuracy chart

CategoryType of sensing elementSheath diameterNormal working temperatureHighest working temperatureAllowable deviation Δt
Measuring rangePermissible deviation
Platinum Rhodium 10 - PlatinumS type≥Φ3mm1100℃1300℃0~1300℃±2.5℃ or ±0.75%t
Nickelchromium - Copper nickelE type≥Φ3mm600℃700℃0~700℃±2.5℃ or ±0.75%t
Nickel chromium - Nickel siliconK type≥Φ3mm800℃950℃0~900℃±2.5℃ or ±0.75%t
Iron - constantanJ type≥Φ3mm500℃600℃0~600℃Not specified
Copper - Copper nickelT type≥Φ3mm350℃400℃<-200℃Not specified
-40~350℃±1.0℃ or ±0.75%t

2. Thermal response time of thermocouple

Sheath diameter (mm)

Thermal response time (s)
Shell typeInsulation type
2.00.40.5
3.00.61.2
4.00.82.5
5.01.24.0
6.02.06.0
8.04.08.0

3. Thermocouple wire structure chart
Thermocouple wire structure chart
4. Selection chart

Branch numberInstalling formMode of connectionWorking end formMultipoint typeAdditional deviceSheath diameterSheath length
B1: Single branch;
B2: Double branch
I1: No fixed device;
I2: Fixed card sets of thread joint;
I3: Movable card sets of thread joint;
I4: Fixed card sets of flange;
I5: Movable card sets of flange
C0: Simple terminals;
C3: Standard waterproof protection head;
C4: Explosion-proof protection head;
C5: Standard plug;
C6: Aviation plug;
C7: Handheld;
C8: Small waterproof protection head;
C9: Direct lead wire
W1: Insulation type;
W2: Shell type;
W3: Open end type
M3: 3 points;
M4: 4 points;
M5: 5 points;
M6: 6 points
S: Sanitary chuck;
H: Heat collector
D3: Φ3;
D4: Φ4;
D5: Φ5;
D6: Φ6;
D8: Φ8
Φ3: 50~15000mm;
Φ4: 50~10000mm;
Φ5: 50~4000mm;
Φ6: 50~2000mm;
Φ8: 50~1000mm

5. Thermocouple installation diagram
Thermocouple installation diagram

Feature

  • High Mechanical Strength: Strong structure with good pressure resistance, suitable for harsh industrial environments.
  • Flexible Installation: Can be bent for curved or space-limited mounting scenarios, enhancing installation convenience.
  • Wide Measurement Range: Sheath thermocouple suitable for various temperature ranges in industrial and laboratory use.
  • Fast Thermal Response: Minimizes dynamic error with rapid response to temperature changes.
  • Leak-Proof Insulated Connector: Designed with anti-electric-leakage plastic molding, crafted through multiple precise processes for safety and reliability.
  • Premium Plastic Components: Quality plastic materials offer durability and insulation.
    Comfortable Handle Design: Ergonomically shaped grip for safe and easy handling.

Tips: How to prevent interference for thermocouple?

  1. Isolation
    Isolation method is to hang thermocouple in the air to isolate thermocouple from refractory brick of furnace wall, and thermocouple is also isolated from support by use of insulation object. The method can prevent interference of high temperature electric leakage.
  2. Shielding
    Shielding method is to make extension wire of thermocouple pass through iron tube or other metal shields to isolate. In this way, it can prevent electromagnetic interference and interference of high voltage electric field. When using this method, iron tube and shields should be connected with the ground well and twist the extension wire as well.
  3. Ground connection
    This method has two forms: The first is to connect the reference end of thermocouple with the ground, and second is to connect the measurement end of thermocouple with the ground.
Only registered users can write reviews
Customers who bought this item also bought

Thermocouple, E type, Sheath

ATO-TC-ES
$46.15
E type thermocouple has the highest thermoelectric force and sensitivity in base metals. Sheath thermocouple have shielded thermocouple wire of common length 500mm and sheath diameter Ф3~Φ8mm, with flexibility, high pressure resistant, fast thermal response time and long operating life. E type thermocouple can directly measure the temperature of liquid, vapor, gas medium and solid surface in the range of 0~700 ℃ in various production processes.